KITOZER insulating safety boots are dielectric footwear worn by electricians working on or near live high voltage equipment, protecting the feet from step voltage and touch current when the worker stands on a floor that may become energized during a fault. The Class 0 leather model is rated for maximum use voltage 15kV AC, making it suitable for 10kV and 35kV switchgear rooms, transformer yards, and high voltage cable joint bays. The boot combines a leather upper for mechanical comfort with a thick rubber outsole for dielectric insulation, and a steel toe cap for impact protection. KITOZER supplies sizes 38 to 46, in black leather, with a test certificate per pair and a retest schedule of every 6 months.
Table of Contents
ToggleProduct Overview
When a high voltage fault occurs, the floor and metalwork around the fault carries a potential gradient. A worker standing on that floor can receive current from feet to hand if they touch an earthed part. Insulating boots break this current path by providing a high resistance barrier between foot and floor. The KITOZER Class 0 boots are proof tested at 20kV before shipment, with leakage current measured below 10mA. The leather upper breathes for all day comfort, while the rubber sole provides the dielectric barrier. The steel toe protects the foot from dropped tools, and the oil resistant outsole handles industrial spills. Each pair is marked with class, size, test date, and next retest date.
Technical Specifications
Class: Class 0 per IEC 60903 for footwear. Maximum use voltage: 15kV AC. Proof test voltage: 20kV for 1 minute. Leakage current: less than 10mA at proof test. Upper: full grain leather, black. Outsole: dielectric rubber, oil and acid resistant. Toe cap: steel, 200J impact. Sole thickness: 5mm rubber dielectric layer. Size range: 38 to 46. Height: 25cm ankle boot. Temperature range: minus 20 to plus 50 degrees Celsius. Standards: IEC 60903, ASTM F1117, GB 12011. Retest interval: every 6 months. Package: cardboard box, with test certificate and user instruction leaflet. KITOZER brand, 24 month shelf life.
Applications
The KITOZER Class 0 boots are worn by high voltage switchgear technicians when working in 10kV and 35kV substations, by transformer maintenance crews, by high voltage cable joint crews, and by live line workers under low voltage class conditions. They are standard PPE in electrical utility substations, industrial plant high voltage rooms, traction power substations for railways, and large building primary substations. For ultra high voltage 110kV and above, KITOZER supplies higher Class 2 and Class 4 boots with thicker soles. The boots are also worn in battery rooms, generator halls, and anywhere a worker may step into an energized zone unexpectedly.
Advantages
Leather upper provides comfort and breathability that pure rubber boots cannot match, reducing fatigue during long shifts. The 5mm dielectric rubber sole handles 15kV continuously without breakdown. Steel toe cap protects against dropped tools, which is common in switchgear rooms. Oil and acid resistant outsole handles transformer oil and battery electrolyte spills without swelling. Each pair is individually tested and certified, meeting utility and industrial safety audit requirements. Size range fits most workers. The boot design is compatible with insulating gloves and hot sticks, forming a complete PPE set. KITOZER boots carry CE and IEC certification for international projects.
Installation and Maintenance
Before each use, inspect the sole for cuts, nails, embedded debris, and oil saturation. Wipe the sole clean. Check the proof test label is within 6 months. Do not use boots with cracked soles or worn tread. Wear with dry socks; do not wear wet socks with insulating boots. After use, wipe clean and dry at room temperature, away from direct heat or sunlight. Store in a dry boot locker, not on a hot floor or near a radiator. Send boots for retest every 6 months to an approved laboratory. Replace the boots after 24 months even if no visible damage, because rubber dielectric properties degrade over time. Keep spare pairs in the substation locker for shift changes.
Available Models and Custom Service
KITOZER stocks the Class 0 15kV leather boots in sizes 38 to 46 for immediate dispatch. Higher Class 2 (26.5kV) and Class 4 (36kV) boots are quoted for ultra high voltage substations. All rubber dielectric versions are available for wet environments where leather would absorb moisture. Steel toe cap is standard, and composite toe cap is quoted for magnetic sensitive areas. KITOZER can supply the boots with a complete PPE bundle including insulating gloves, hot stick, and voltage detector for utility crews. Each pair ships with a test certificate, and bulk orders of 50 pairs or more receive project pricing.
Price
From $65 per pair for Class 0 15kV leather insulating boots. Contact +86 13922289957 for PPE project bulk pricing and size ranges.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com