KITOZER insulation rubber mat is a dielectric safety flooring laid in front of high voltage switchboards, transformers, battery rooms, and electrical control panels to protect operators from electric shock in case of accidental contact with live parts. The 2mm thick 5kV class mat is the most commonly specified grade for low voltage switchboard rooms up to 1000V, UPS rooms, and battery banks. Manufactured from high grade natural rubber with carbon free compounding, the mat provides a high resistance barrier between worker feet and grounded floor, reducing touch current through the body during a fault. KITOZER supplies the mat in rolls 1m wide by 10m long, in red or black, with beveled edges for trip hazard reduction.
Table of Contents
ToggleProduct Overview
When an electrician works on an open switchboard, even a momentary touch of a live conductor can send current through the body to earth. A dry concrete floor is not reliably insulating because of dust, moisture, and conductive floor paint. The KITOZER rubber mat creates a known high resistance barrier, so the fault current through the body stays below the safe threshold. The mat is tested to IEC 61111 and ASTM D178 standards, with proof voltage testing at 2 times rated voltage and with leakage current measurement. KITOZER supplies each roll with a test certificate, color coding, and size labeling so inspection teams can verify grade and expiry date. The mat is also resistant to oil, acid, and UV, making it suitable for industrial rooms.
Technical Specifications
Class: Class 0 per IEC 61111, rated 5kV maximum use voltage. Thickness: 2mm. Width: 1m standard. Length: 10m roll. Color: red or black. Proof test voltage: 10kV for 1 minute. Leakage current: less than 1mA at proof test. Volume resistance: more than 10 to the 12 ohm cm. Dielectric strength: 20kV per mm. Temperature range: minus 15 to plus 60 degrees Celsius. Oil resistance: IP class 1, no swelling after 24h in mineral oil. Acid resistance: dilute sulfuric and sodium hydroxide tested. Standards: IEC 61111, ASTM D178, GB 17622. Edges: beveled 30 degrees. Package: rolled on cardboard core, wrapped in plastic. KITOZER brand, with test certificate per roll.
Applications
The 2mm 5kV mat is laid in front of low voltage main switchboards, MCC panels, UPS input and output cabinets, battery racks, inverter panels, and motor control centers. It is also used on the floor of electrical maintenance workshops, high voltage test areas, and in front of charging stations for electric forklifts. In data centers the mat is laid in the PDU corridor to protect facility engineers during live work. In telecom exchanges it protects technicians working on DC power bays. In industrial plants it is placed at every electrical room door and along the front of every panel. For high voltage rooms above 1000V, KITOZER supplies thicker 3mm and 5mm Class 2 and Class 4 mats.
Advantages
The 2mm thickness is flexible enough to roll and cut on site without cracking, yet thick enough to provide reliable 5kV insulation. Carbon free compounding avoids the surface tracking that conductive filled mats develop after months of use. Oil and acid resistance means the mat survives industrial spills without degrading. Beveled edges prevent trip hazards, a common complaint with square cut mats. Color coding (red for Class 0) lets safety inspectors verify grade at a glance. Each roll comes with an individual test certificate, which is required by electrical inspection codes. KITOZER mats carry CE and IEC certification, and the roll format reduces seams compared with square tiles.
Installation and Maintenance
Clean the floor before laying, remove oil and dust, and dry completely. Unroll the mat and let it flatten for 24 hours before trimming. Cut to length with a sharp knife. Do not tape the mat to the floor, because trapped moisture underneath reduces insulation. Overlap seams by 50mm or join with KITOZER beveled edge tape. Inspect the mat monthly for cuts, cracks, nail holes, and oil saturation. Wipe clean with dry cloth, never use solvent. Perform a dielectric withstand test every 12 months: apply the proof test voltage for 1 minute and measure leakage current. Replace the mat if leakage exceeds 1mA or if visible cuts penetrate the rubber. Store spare rolls flat in a dry room away from direct sunlight.
Available Models and Custom Service
KITOZER stocks the 2mm Class 0 red mat in 1x10m rolls for immediate dispatch. Black color is available on request. Higher class 3mm Class 2 (17kV) and 5mm Class 4 (36kV) mats are quoted for high voltage rooms above 1kV. Anti-static and conductive versions are available for electronics assembly rooms and explosive area floors. KITOZER can supply pre-cut mats to exact panel dimensions with beveled edges, reducing on site cutting waste. Each roll ships with a test certificate, and bulk orders of 50 rolls or more receive factory pricing. Floor paint marking tape is available to outline the mat perimeter for inspection compliance.
Price
From $35 per square meter for 2mm Class 0 red mat. Rolls 1x10m from $320. Contact +86 13922289957 for electrical room flooring project pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com