1. System Introduction
The KITOZER intelligent liquid cooling cabinet is a high-efficiency heat dissipation infrastructure tailored for new-generation data centers, AI computing clusters and edge computing nodes. Adopting a modular design concept, it integrates advanced liquid cooling technology, intelligent monitoring system and redundant guarantee mechanism. It supports ultra-high power density heat dissipation of 10kW~100kW per cabinet with a PUE as low as below 1.10, delivering a green, efficient and stable cooling solution for high-density computing scenarios.
Guided by four core design principles of precision heat dissipation, intelligent control, high efficiency & energy saving, safety & reliability, the system applies multiple liquid cooling technologies including cold plate, immersion and spray cooling to directly act on heat sources. It greatly improves heat dissipation efficiency and reduces overall energy consumption of data centers. Meanwhile, it supports rapid deployment and flexible expansion, fully adapting to full-scenario application requirements from micro edge computer rooms to large-scale intelligent computing centers.
2. System Composition
The KITOZER intelligent liquid cooling cabinet system adopts a three-layer architecture, forming a complete heat dissipation link from heat source to cold source. All components work collaboratively to ensure stable and efficient system operation.
| Level | Core Components | Function Description |
| Cabinet Level | Intelligent liquid cooling cabinet main bodyLiquid cooling manifold distribution unitQuick connectors & flexible pipelinesLiquid leakage detection systemIntelligent PDUCabinet monitoring module | Carry server equipment, realize coolant distribution and recovery inside the cabinet, real-time monitor cabinet temperature, pressure, leakage and other parameters, and provide safe power supply and remote management capabilities. |
| Computer Room Level | Coolant Distribution Unit (CDU)Plate heat exchangerCirculating pump setFiltration systemLiquid replenishment deviceComputer room monitoring platform | Supply stable coolant circulation for multiple cabinets, realize heat transfer through secondary side heat exchange, and achieve precise flow & temperature control and automatic fault switching. |
| Cold Source Level | Dry cooler / Cooling towerChiller (optional)Backup cold source system | Provide primary cold source to dissipate heat to the environment, support automatic switching between natural cooling and mechanical refrigeration to maximize energy-saving benefits. |

2.1 Cabinet Main Structure
- Standard 19-inch rack, supporting 42U/48U installation space and compatible with mainstream server equipment
- High-strength steel structure with load capacity ≥1500kg and IP54 protection level
- Modular design supporting rapid switching of cold plate, immersion and spray liquid cooling solutions
- Integrated cable management system, supporting multiple wiring methods including top-in top-out and bottom-in bottom-out
2.2 Liquid Cooling Distribution System
- 304 stainless steel manifold with design pressure of 1.0MPa, corrosion resistance and long service life
- Custom self-sealing quick connectors with zero leakage during plugging and unplugging, supporting online server replacement
- Food-grade flexible pipelines with low flow resistance, adapting to complex wiring environments inside cabinets
- Flow regulating valves support independent flow control for single server to meet differentiated heat dissipation requirements
2.3 Intelligent Monitoring System
- Distributed sensor network, real-time collection of temperature (accuracy ±0.5℃), pressure (accuracy ±0.01MPa), flow and other parameters
- Edge computing gateway supports local data processing and edge decision-making with response time ≤1 second
- Compatible with multiple communication protocols such as SNMP, Modbus and TCP/IP for seamless access to third-party management platforms
- Intelligent alarm mechanism with multi-level alarm and automatic fault isolation to ensure system operation safety

3. System Classification
KITOZER intelligent liquid cooling cabinets are classified by heat dissipation technology, deployment scale and application scenarios to meet diversified user requirements.
3.1 Classification by Heat Dissipation Technology
| Technology Type | Core Features | Application Scenarios | Heat Dissipation Capacity | PUE Range |
| Cold Plate Liquid Cooling Cabinet | Indirect contact heat dissipation. Cold plates are attached to high-heat devices such as CPU/GPU without changing the original server structure, featuring strong compatibility | Existing computer room renovation, general computing scenarios, edge computing nodes | 10kW~40kW per cabinet | 1.15~1.25 |
| Immersion Liquid Cooling Cabinet | Direct contact heat dissipation. Servers are fully immersed in insulating coolant with extremely high heat dissipation efficiency and low noise | AI training clusters, supercomputing centers, high-density computing scenarios | 40kW~100kW per cabinet | 1.05~1.10 |
| Spray Liquid Cooling Cabinet | Directional coolant spraying on chip surfaces, balancing heat dissipation efficiency and maintenance convenience | High-performance computing, database clusters, mixed load scenarios | 30kW~80kW per cabinet | 1.10~1.20 |

3.2 Classification by Deployment Scale
- Single Cabinet Independent System: Integrated CDU functions without external cooling equipment, featuring flexible deployment and plug-and-play, suitable for micro data centers and edge computing nodes.
- Multi-cabinet Cluster System: Adopts distributed CDU design to provide centralized cooling for multiple cabinets, with redundant design and high reliability for small and medium-sized data centers.
- Large Modular System: Compliant with OCP open standards, supporting rapid cabinet-level expansion and adapting to large-scale intelligent computing centers with single cabinet power density over 100kW.
3.3 Classification by Application Scenario
- Edge Liquid Cooling Cabinet: Compact design, supporting wide-temperature operation (-40℃~55℃), applicable to 5G base stations, industrial edge computing and outdoor computer rooms.
- AI Training Dedicated Cabinet: Optimized for GPU clusters, supporting multi-card parallel heat dissipation, compatible with high-performance computing cards such as NVIDIA H100/A100 and AMD MI250.
- High-density Storage Cabinet: Optimized airflow and liquid flow design, adapting to high-density storage servers, reducing vibration impact and extending hard disk service life.
- Liquid Cooling Container: Integrated prefabricated design with on-site rapid deployment within 7 days, suitable for emergency computer rooms, temporary computing capacity expansion and remote area data centers.

4. System Configuration List (Brand: KITOZER)
4.1 Standard Configuration List of Cold Plate Liquid Cooling Cabinet
| No. | Equipment Name | Model | Specification Parameters | Quantity | Remarks |
| 1 | Intelligent Liquid Cooling Cabinet | KITOZER-LC-CP42U | 42U, 600W×1200D×2200Hmm, load capacity 1500kg | 1 Set | Including front/rear doors, side panels, top & bottom panels |
| 2 | Cabinet Liquid Cooling Manifold | KITOZER-MF-300 | 304 stainless steel, 1-in 12-out, flow rate 300L/min, working pressure 1.0MPa | 1 Set | Including liquid inlet/return main pipelines |
| 3 | Cold Plate Assembly | KITOZER-CP-200 | Copper-aluminum composite material, compatible with 2U/4U servers, heat exchange area ≥0.8m² | On-demand | Including mounting bracket and thermal conductive medium |
| 4 | Quick Connector | KITOZER-QD-10 | Self-sealing, bore diameter 10mm, plugging life ≥5000 times | On-demand | 2 pcs per server (inlet & return) |
| 5 | Flexible Pipeline | KITOZER-HOSE-10 | Food-grade PE material, inner diameter 10mm, pressure resistance 1.6MPa | On-demand | Customizable length |
| 6 | Liquid Leakage Detection System | KITOZER-LD-8 | 8-channel, detection accuracy 0.1ml, response time ≤2s | 1 Set | Including sensors and alarm module |
| 7 | Intelligent PDU | KITOZER-PDU-32A | 32A input, 16-channel output, supporting remote monitoring and switch control | 2 Sets | Redundant configuration |
| 8 | Cabinet Monitoring Module | KITOZER-IM-200 | Supports temperature/humidity/pressure/flow/access control/video monitoring | 1 Set | Equipped with 7-inch touch screen |
| 9 | Cable Management System | KITOZER-CM-42U | Adapted to 42U cabinets, supporting separate management of power and signal cables | 1 Set | Including cable organizers and trunking |
| 10 | Safety Protection Kit | KITOZER-SP-01 | Including fire extinguisher, emergency lighting, protective gloves | 1 Set | Standard safety configuration |
4.2 CDU Centralized Cooling Unit Configuration List
| No. | Equipment Name | Model | Specification Parameters | Quantity | Remarks |
| 1 | Coolant Distribution Unit (CDU) | KITOZER-CDU-120 | Dual-pump redundancy, maximum flow 120m³/h, temperature control accuracy ±1℃ | 1 Set | Including control system and touch screen |
| 2 | Plate Heat Exchanger | KITOZER-HE-100 | Heat exchange area 100m², heat exchange efficiency ≥95% | 1 Set | 316L stainless steel material |
| 3 | Circulating Pump Set | KITOZER-PUMP-50 | Flow 50m³/h, head 30m, variable frequency control | 2 Sets | Master-standby automatic switching, fault self-switching supported |
| 4 | Precision Filtration System | KITOZER-FILTER-200 | Filtration accuracy 10μm, automatic backwashing, differential pressure alarm | 1 Set | Including front and rear pressure gauges |
| 5 | Liquid Replenishment Device | KITOZER-FILL-50 | 50L capacity, automatic liquid replenishment, low liquid level alarm | 1 Set | Including liquid level sensor |
| 6 | Electrical Control Cabinet | KITOZER-EC-60 | Equipped with PLC, frequency converter, relay and other control components | 1 Set | Supports remote communication |
| 7 | Monitoring Software | KITOZER-MON-3.0 | Supports Web/mobile terminal access, real-time monitoring and data analysis | 1 Set | Free lifelong software upgrade service |
4.3 Cold Source System Configuration List
| No. | Equipment Name | Model | Specification Parameters | Quantity | Remarks |
| 1 | Dry Cooler | KITOZER-DC-200 | Heat exchange capacity 200kW, supporting natural cooling | 1 Set | Including fan and spray system |
| 2 | Backup Chiller | KITOZER-CH-150 | Cooling capacity 150kW, energy efficiency ratio ≥4.2 | 1 Set | Optional configuration for extreme working condition guarantee |
| 3 | Pipeline System | KITOZER-PIP-01 | Seamless steel pipe, pressure resistance 1.6MPa, thermal insulation treatment | 1 Set | Including valves, flanges and brackets |
| 4 | Automatic Control System | KITOZER-ACS-01 | Supports intelligent switching between natural cooling and mechanical refrigeration | 1 Set | Including temperature and pressure sensors |

5. System Schematic Diagram
5.1 Working Principle of Cold Plate Liquid Cooling System
| Plain Text Server Heat Source (CPU/GPU) → Cold Plate (Copper-aluminum Composite) → Flexible Pipeline → Cabinet Manifold → CDU (Circulating Pump → Plate Heat Exchanger → Filtration System) → Dry Cooler/Cooling Tower → Environment ↑ | | ↓ └─────────────────────────────────┘ (Secondary Coolant Circulation Path) |
System Working Process:
- The cold plate is closely attached to high-heat components such as server CPU/GPU through thermal conductive medium to absorb heat.
- The heated coolant flows into the cabinet manifold through flexible pipelines, converges and is transported to the CDU.
- The CDU delivers the coolant to the plate heat exchanger via circulating pumps for heat exchange with the primary cold source.
- The cooled coolant returns to the cabinet manifold and is redistributed to each cold plate to form a closed-loop circulation.
- The primary cold source dissipates heat to the environment through dry coolers or cooling towers to complete the heat dissipation process.
- The whole link realizes real-time monitoring of temperature, pressure, flow and other parameters to ensure stable system operation.
5.2 Working Principle of Immersion Liquid Cooling System
| Plain Text Server (Fully Immersed in Insulating Coolant) → Coolant (Heat Absorption) → Cabinet Internal Circulating Pump → External Heat Exchanger → Dry Cooler/Cooling Tower → Environment ↑ | | ↓ └──────────────────────────────┘ (Coolant Circulation Path) |
System Features:
- Servers are fully immersed in 3M Novec or customized insulating coolant, with heat dissipation efficiency over 30% higher than cold plate cooling.
- Adopts single-phase/two-phase immersion technology; the two-phase system achieves a PUE as low as 1.05 with remarkable energy-saving effect.
- Integrated circulating pump and heat exchanger inside the cabinet support independent single-cabinet operation or connection to centralized CDU systems.

6. Product Technical Parameters
6.1 Technical Parameters of Cold Plate Liquid Cooling Cabinet
| Parameter Category | Detailed Specifications |
| Physical Parameters | Dimension: 600W×1200D×2200Hmm (42U)Weight: 200kg (excluding equipment)Material: High-quality SPCC steel with electrostatic spray surface treatmentProtection Level: IP54 |
| Heat Dissipation Performance | Single cabinet heat dissipation capacity: 10kW~40kWCoolant inlet temperature: 20℃~35℃Coolant outlet temperature: ≤45℃Temperature control accuracy: ±1℃ |
| Liquid Circuit System | Working pressure: 0.3~0.8MPaMaximum flow rate: 300L/minManifold interface: 12~24 channels (optional)Quick connector: bore diameter 10mm, plugging force <50N |
| Electrical Parameters | Input voltage: 380V/220V AC, 50HzPDU output: 16-channel C13/C19 interfacesMonitoring module power consumption: ≤50WLiquid leakage detection sensitivity: 0.1ml |
| Environmental Parameters | Operating temperature: -10℃~40℃Relative humidity: 10%~90% (non-condensing)Altitude: ≤2000mSeismic grade: Earthquake resistance intensity of grade 8 |
| Intelligent Features | Support remote monitoring and managementAutomatic fault alarm and positioningMulti-protocol access (Modbus/TCP/IP, SNMP)Mobile APP real-time monitoring supported |
6.2 Technical Parameters of CDU Centralized Cooling Unit
| Parameter Category | Detailed Specifications |
| Physical Parameters | Dimension: 800W×1200D×2000HmmWeight: 500kg (with liquid)Installation method: Floor-standing / cabinet type |
| Performance Parameters | Maximum liquid supply capacity: 120m³/hTemperature control range: 15℃~35℃Temperature control accuracy: ±0.5℃Pressure control accuracy: ±0.02MPa |
| Pump Set Configuration | Dual-pump redundant design with automatic master-standby switchingVariable frequency control, flow adjustment range: 30%~100%Pump efficiency: ≥80% |
| Heat Exchange System | Plate heat exchanger, heat exchange area: 100m²Heat exchange efficiency: ≥95%Material: 316L stainless steel |
| Monitoring System | 7-inch color touch screen, local/remote control supportedReal-time monitoring parameters: inlet/outlet temperature & pressure, flow, liquid level, energy consumptionSupport fault diagnosis and automatic protection functions |

7. Product Application Scope
With the advantages of high heat dissipation efficiency, low energy consumption and flexible deployment, KITOZER intelligent liquid cooling cabinets are widely applied in the following scenarios:
7.1 Data Center Field
- Large-scale Intelligent Computing Centers: Adapt to ultra-high power density AI training clusters of 40kW~100kW per cabinet with PUE as low as 1.05, greatly reducing operating costs.
- Edge Data Centers: Compact design supports wide-temperature operation, suitable for 5G base stations and industrial internet edge nodes.
- High-density Computer Room Renovation: No large-scale infrastructure transformation is required. The single cabinet power of traditional computer rooms can be increased from 5kW to over 40kW, extending the service life of computer rooms.
7.2 Industry-specific Scenarios
| Industry | Typical Applications | Core Values |
| Financial Industry | High-frequency trading systems, core database clusters | Ensure stable system operation, reduce computer room energy consumption and meet green financial requirements |
| Internet Industry | Short video AI processing, cloud computing data centers | Support rapid capacity expansion, adapt to sudden traffic, reduce PUE and enhance market competitiveness |
| Scientific Research Field | Supercomputers, meteorological & ocean simulation platforms | Meet ultra-high power density heat dissipation requirements and support long-term stable operation |
| Manufacturing Industry | Industrial internet platforms, intelligent manufacturing data centers | Adapt to complex factory environments and support integrated edge computing and centralized management |
| Medical Industry | Medical image processing, gene sequencing platforms | Guarantee high-precision computing, reduce equipment noise and improve working environment |
| Energy Industry | Smart grid dispatching systems, new energy monitoring platforms | Adapt to remote deployment, support natural cooling and reduce operation and maintenance costs |
7.3 Special Application Scenarios
- Liquid Cooling Container Data Center: Factory prefabricated with on-site rapid deployment within 7 days, suitable for emergency disaster relief, temporary computing capacity expansion and remote data center construction.
- Vehicle/ship-mounted Data Center: Anti-vibration design supports wide-temperature operation, adapting to mobile computing scenarios.
- Military/Aerospace Industry: High-reliability design adapts to extreme environments and meets military computing and data storage requirements.

8. Product Advantages
8.1 High-efficiency Heat Dissipation & Extreme Energy Saving
- 50%+ Higher Heat Dissipation Efficiency: Compared with traditional air cooling, liquid cooling improves heat dissipation efficiency by more than 50%, increasing single cabinet power density from 5kW to over 40kW.
- Ultra-low PUE: Immersion liquid cooling system PUE reaches 1.05, and cold plate liquid cooling system PUE ranges from 1.15 to 1.25, saving 30%-50% energy compared with traditional air-cooled computer rooms.
- High Natural Cooling Utilization: Support wide temperature range operation of 15℃~35℃, greatly extending natural cooling time and further reducing energy consumption.
8.2 Intelligent Management & Convenient O&M
- Full-link Monitoring: Real-time monitoring of more than 20 parameters including temperature, pressure, flow and leakage to pre-warn potential faults.
- Remote Intelligent Management: Support Web/mobile remote monitoring and control to realize unattended operation and reduce O&M costs.
- Automatic Fault Processing: Support automatic fault isolation and master-standby switching, achieving system availability of 99.999%.
- Intelligent Energy Consumption Analysis: Built-in AI algorithm optimizes operating parameters to achieve the best balance between energy consumption and heat dissipation efficiency.
8.3 Safety & Stable Operation
- Multi-level Safety Protection: Multiple safety mechanisms including liquid leakage detection, overpressure protection, overheating protection and power-off protection ensure equipment and personnel safety.
- Redundant Design: CDU adopts dual-pump, dual-heat exchanger and dual-power redundant configuration to avoid system shutdown caused by single-point failure.
- Insulating Coolant: The immersion system adopts 3M Novec and other insulating coolants, which are non-conductive and non-flammable to ensure server safety.
- Fire & Explosion Proof: The whole system adopts flame-retardant materials, complying with UL94 V-0 fire protection standard.
8.4 Flexible Deployment & Strong Adaptability
- Modular Design: Support rapid switching of cold plate, immersion and spray liquid cooling solutions to adapt to different application scenarios.
- Rapid Deployment: Factory prefabrication reduces on-site installation time by 70%, supporting small-scale data center deployment within 7 days.
- Seamless Expansion: Support cabinet-level expansion, enabling smooth scaling from single cabinet to thousands of cabinets.
- Standard Equipment Compatibility: Adapt to mainstream servers, switches and other IT equipment without customized modification.
9. Bid-winning Control Parameters
9.1 Core Technical Parameter Requirements
- Heat Dissipation Capacity: Single cabinet heat dissipation capacity ≥40kW, maximum single cabinet power density ≥60kW.
- PUE Value: Cold plate liquid cooling system PUE ≤1.20, immersion liquid cooling system PUE ≤1.10.
- Temperature Control: Coolant outlet temperature control accuracy ≤±1℃, supporting wide range adjustment of 15℃~35℃.
- Liquid Leakage Detection: The system is equipped with distributed liquid leakage detection function with detection sensitivity ≤0.1ml and response time ≤2 seconds.
- Redundant Design: CDU adopts dual-pump and dual-heat exchanger redundant configuration with automatic fault switching and switching time ≤5 seconds.
- Quick Connector: Adopt self-sealing quick connectors with plugging life ≥5000 times and zero liquid leakage during plugging and unplugging.
- Material Requirements: Key liquid circuit components (manifold, heat exchanger) adopt 304/316L stainless steel with design pressure ≥1.0MPa.
- Monitoring Capability: Support real-time monitoring of more than 20 parameters such as temperature, pressure, flow, liquid level and energy consumption, with remote management function.
9.2 Qualification & Certification Requirements
- Possess ISO9001 quality management system certification, ISO14001 environmental management system certification and ISO45001 occupational health and safety management system certification.
- The liquid cooling system has international certifications such as CE, UL and ETL, complying with IEC61935 standards.
- The liquid leakage detection system is equipped with third-party test reports with detection accuracy meeting industry standards.
- The product has passed national data center energy-saving product certification with PUE reaching the national first-class energy efficiency standard.
9.3 Service & Guarantee Requirements
- Provide a warranty period of no less than 5 years, and the warranty period for core components (CDU, pump set, heat exchanger) is no less than 3 years.
- Provide 7×24-hour technical support with fault response time ≤2 hours and on-site service time ≤24 hours.
- Provide one-stop services including system design, installation, commissioning and training.
- Provide lifelong free software upgrade services to ensure long-term stable system operation.
10. Product Solution
10.1 Solution Design Process
The KITOZER intelligent liquid cooling cabinet solution follows a five-step process of demand analysis → solution design → product selection → deployment implementation → operation and maintenance service to ensure accurate matching with user requirements.
- Demand Analysis: Evaluate core requirements such as user IT equipment power density, deployment scale, computer room conditions and energy-saving goals.
- Solution Design: Select cold plate/immersion/spray liquid cooling technical routes according to requirements, and design cabinet layout, pipeline routing and CDU configuration.
- Product Selection: Select matching liquid cooling cabinets, CDU, cold sources and other products based on the design scheme to ensure system compatibility and reliability.
- Deployment Implementation: Adopt factory prefabrication + on-site rapid installation mode, with professional teams completing system commissioning and acceptance.
- Operation & Maintenance Service: Provide remote monitoring platform and regular maintenance services to ensure long-term stable system operation.
10.2 Typical Scenario Solutions
10.2.1 AI Intelligent Computing Center Solution
Solution Overview: Adopt immersion liquid cooling cabinet + distributed CDU + natural cooling system to adapt to 40kW~100kW per cabinet AI training clusters with PUE as low as 1.05.
Core Configuration:
- KITOZER-LC-IM48U immersion liquid cooling cabinet, supporting 48U installation space and single cabinet heat dissipation capacity of 60kW
- KITOZER-CDU-200 distributed CDU, providing centralized cooling for 10 cabinets
- 3M Novec 7300 insulating coolant, non-conductive and non-flammable, adapting to high-density heat dissipation requirements of AI servers
- Intelligent monitoring platform, optimizing coolant flow and temperature via AI algorithm to maximize energy-saving effect
Implementation Effect:
- Single cabinet power density increased to 8 times that of traditional air cooling, and computer room space utilization increased by 60%
- PUE reduced from 1.8 (traditional air cooling) to 1.05, with annual power saving rate over 40%
- Server failure rate reduced by 50% and service life extended by 3 years
- Noise reduced below 60dB, improving computer room working environment
10.2.2 Edge Data Center Solution
Solution Overview: Adopt cold plate liquid cooling cabinet + integrated CDU + dry cooler system to adapt to 10kW~20kW per cabinet edge computing nodes and support wide-temperature operation.
Core Configuration:
- KITOZER-LC-CP42U cold plate liquid cooling cabinet, compact size 600W×1000D×2000Hmm
- KITOZER-CDU-50 integrated CDU with built-in pump set, heat exchanger and control system, no external cold source required
- High-efficiency dry cooler supporting operation at -40℃~55℃ to maximize natural cooling utilization
- Edge computing gateway supporting local data processing and remote management for edge computing scenarios
Implementation Effect:
- Deployable in non-standard environments such as warehouses and workshops without professional computer rooms
- Deployment time shortened to within 7 days to quickly respond to edge computing requirements
- Support wide-temperature operation, reducing computer room construction costs by over 60%
- Remote monitoring and management reduce manpower investment in operation and maintenance
10.2.3 Traditional Computer Room Renovation Solution
Solution Overview: Adopt cold plate liquid cooling cabinet + centralized CDU + existing cold source reuse to increase single cabinet power from 5kW to 40kW without changing computer room structure.
Core Configuration:
- KITOZER-LC-CP42U cold plate liquid cooling cabinet compatible with existing 19-inch servers
- KITOZER-CDU-120 centralized CDU, reusing existing chillers as cold sources
- Quick connectors and flexible pipelines support online server replacement without business interruption
- Liquid leakage detection system ensures computer room safety and prevents equipment damage from liquid leakage
Implementation Effect:
- No large-scale computer room infrastructure transformation required, reducing renovation costs by 70%
- Single cabinet power density increased to 40kW to meet new IT equipment deployment requirements
- PUE reduced from 1.8 to 1.2 with annual power saving rate of 33%
- Support online capacity expansion without affecting existing business operation
11. Product Application Cases
11.1 Case 1: AI Training Center of A Leading Internet Company
Project Background: The user built a new AI training center with 100 NVIDIA H100 GPU servers deployed, achieving single cabinet power density of 60kW, which cannot be met by traditional air cooling heat dissipation.
Solution: Adopt KITOZER immersion liquid cooling cabinet + distributed CDU + natural cooling system with target PUE of 1.08.
Deployment Scale: 100 sets of KITOZER-LC-IM48U immersion liquid cooling cabinets, 10 sets of KITOZER-CDU-200 distributed CDU, 5 sets of dry cooler systems.
Implementation Effect:
- Single cabinet heat dissipation capacity reaches 60kW, fully meeting GPU server heat dissipation requirements
- PUE stably maintained at 1.07, saving 4468 MWh of electricity annually, equivalent to the annual power consumption of 1500 households
- Server failure rate reduced by 50% and maintenance costs decreased by 30%
- Computer room space utilization increased by 60%, supporting rapid subsequent capacity expansion
11.2 Case 2: Core Database Center of A Financial Institution
Project Background: The user’s core database center faced capacity expansion bottlenecks. Traditional air cooling only supports 5kW single cabinet power, failing to meet the deployment requirements of new database clusters.
Solution: Adopt KITOZER cold plate liquid cooling cabinet + centralized CDU + existing cold source reuse to increase single cabinet power to 20kW without changing computer room structure.
Deployment Scale: 50 sets of KITOZER-LC-CP42U cold plate liquid cooling cabinets, 5 sets of KITOZER-CDU-120 centralized CDU, reusing existing chillers.
Implementation Effect:
- Completed deployment within 30 days without transforming the computer room and affecting core business operation
- Single cabinet power density increased to 20kW to support new database cluster deployment
- PUE reduced from 1.7 to 1.2 with annual power saving rate of 29%
- The liquid leakage detection system ensures core data security with zero safety accidents
11.3 Case 3: Industrial Internet Edge Node Project
Project Background: The user deployed industrial internet edge nodes in the factory, requiring 10 edge computing servers to be deployed in workshop environments without professional computer room conditions.
Solution: Adopt KITOZER cold plate liquid cooling cabinet + integrated CDU + dry cooler system to support wide-temperature environment operation.
Deployment Scale: 10 sets of KITOZER-LC-CP42U cold plate liquid cooling cabinets, 1 set of KITOZER-CDU-50 integrated CDU, 1 set of high-efficiency dry cooler.
Implementation Effect:
- Successfully deployed in workshop environments without professional computer rooms, reducing construction costs by 80%
- Support operation at -10℃~45℃, adapting to complex factory environments
- Deployment completed in only 5 days to quickly respond to industrial internet construction requirements
- Remote monitoring and management reduce manpower investment and operational costs
12. Search Keywords, SEO & Tags
12.1 Core Search Keywords
Intelligent liquid cooling cabinet, KITOZER liquid cooling cabinet, cold plate liquid cooling cabinet, immersion liquid cooling cabinet, spray liquid cooling cabinet, liquid cooling CDU, data center liquid cooling solution, AI computing center liquid cooling, edge data center liquid cooling, high-density computer room liquid cooling renovation, green data center solution, low PUE liquid cooling system, liquid cooling cabinet bid-winning parameters, liquid cooling cabinet application cases
12.2 SEO Optimization Guidelines
- Title Optimization: Include core keyword “KITOZER Intelligent Liquid Cooling Cabinet Solution” to highlight brand and core value.
- Content Optimization: Control core keyword density at 2%~5% and naturally integrate keywords into each chapter.
- Image Optimization: Add alt tags with core keywords for system schematic diagrams and product images.
- Structure Optimization: Adopt clear chapter structure and H3 heading tags to improve search engine readability.
- Link Optimization: Internal links point to relevant product pages, and external links cite authoritative industry reports and standards.
12.3 Tag Classification
| Tag Type | Tag Content |
| Product Type | Intelligent Liquid Cooling Cabinet, Liquid Cooling CDU, Cold Plate Liquid Cooling, Immersion Liquid Cooling, Spray Liquid Cooling |
| Application Scenario | AI Intelligent Computing Center, Edge Data Center, High-density Computer Room, Traditional Computer Room Renovation, Financial Data Center, Internet Data Center |
| Core Advantages | Low PUE, High-efficiency Heat Dissipation, Intelligent Monitoring, Safety & Reliability, Rapid Deployment, Flexible Expansion |
| Technical Features | Modular Design, Redundant Configuration, Natural Cooling, Liquid Leakage Detection, Remote Management |
| Industry Standards | ISO9001, ISO14001, CE Certification, UL Certification, National First-class Energy Efficiency |