KITOZER Interlock Shield Door: Dual Door Airlock For High Security TEMPEST Room

Product Overview

KITOZER interlock shield door system is a two-door airlock assembly designed for high-security shielded rooms where both RF containment and physical access control must be enforced simultaneously. The inner and outer shield doors are electrically interlocked so that only one can be opened at a time, preventing the shield envelope from being breached during entry or exit. This airlock configuration is mandatory in TEMPEST facilities, classified government labs, and secure data centers where a single open door would otherwise allow an uncontrolled RF path. The system integrates access-control card readers, door status monitoring, and automatic lighting in the small airlock vestibule, turning a simple doorway into a controlled security transition.

Technical Specifications

The system consists of two matching 1000 mm by 2100 mm manual hinged shield doors, each rated 100 dB from 10 kHz to 1 GHz with beryllium-copper finger strips and a three-point cam lock. Between the doors sits a 1200 mm deep vestibule with a 600 mm wide interior, sized for one person at a time. The interlock controller prevents opening either door while the other is unlocked, and requires the outer door to close and seal before the inner door can be released. A card reader and request-to-exit button are fitted on each side. Status LEDs indicate which door may be opened. A manual key override allows emergency release. The controller provides dry contacts to the facility access-control system and logs every door cycle with timestamp.

Application Scenarios

This interlock airlock is the standard entrance for TEMPEST-certified rooms, government secure processing centers, defense contractor labs, and high-security finance operations. It is also used as the controlled entrance to shielded MRI control rooms and to Faraday cages holding cryptographic hardware. The airlock is particularly valuable where the shielded room sits inside a publicly accessible corridor: the outer door keeps the public side separate, while the inner door maintains RF containment. Facilities handling export-controlled technology use the system to combine physical access logging with RF-secure entry.

Advantages and Features

The interlock logic is the core feature: it makes it impossible by design to leave both doors open simultaneously, which removes the most common procedural cause of shield leakage. The system is self-monitoring, with alarm contacts that signal if a door is held open too long or if an interlock fault occurs. The two-door arrangement doubles the RF attenuation at the entrance, because any leakage through the outer door must also pass the inner door. KITOZER supplies the airlock pre-wired and tested, so installation crews only need to connect power and the access-control interface. Door cycle logs support compliance audits for security teams.

Installation and Maintenance Recommendations

Install both doors on a rigid, level frame and bond each to the room shield independently. Test the interlock logic before the room is put into service, verifying that neither door opens while the other is unlocked. Mount the controller in a locked equipment cabinet and seal the cabling penetrations. During monthly inspection, check finger strips on both doors and confirm that the card readers and request-to-exit buttons respond. Annually, verify the emergency release and alarm logging. Keep a log of interlock faults, because repeated faults usually indicate worn finger strips or a misaligned door. Train authorized users on the sequence, especially on the need to wait for the inner door release before attempting to enter.

Configuration and Options

The base interlock airlock includes two 1000 mm by 2100 mm shield doors, the 1200 mm vestibule, interlock controller, card readers, request-to-exit buttons, status LEDs, and a dry-contact alarm interface. Optional upgrades cover a biometric reader in place of a card reader, a request-to-exit loop detector for wheelchair users, a small shielded observation window in each door, an emergency break-glass release, and a logging PC that records every door cycle for audit. KITOZER also supplies a motorized inner or outer door variant for high-traffic installations, and can integrate the interlock with the facility VMS and access-control platform. The vestibule can be lengthened to accommodate a small workbench or scanner. When ordering, specify the required access-control protocol, whether doors are manual or motorized, and the certification standard that the installation must satisfy.

Warranty and Support

KITOZER warrants the interlock airlock for five years on the door leaves and frames, and two years on controller, readers, and finger strips. Door-cycle logging and interlock test reports ship with each set, and the company supports access-control integration. Spare controllers and readers are stocked for fast replacement. Lead time is six to ten weeks for a complete airlock set, and the company supports access-control integration on site during the commissioning visit and provides a full cycle-log report.

Price

From $18,500 per airlock set. Contact +86 13922289957 for access-control integration and certification support.