KITOZER Isolation Transformer: 5kVA Shielded For Medical IT

KITOZER 5 kVA shielded isolation transformer provides galvanic separation between the mains supply and sensitive medical, laboratory, or IT loads while suppressing conducted common-mode noise through an electrostatic shield between primary and secondary windings. The shield is bonded to protective earth, diverting displacement current and noise coupling across the winding capacitance. This reduces leakage current on the isolated side and helps medical IT systems comply with IEC 60601-1 isolation requirements and IT grounding concepts in wet areas.

The toroidal or laminated core construction offers low magnetic stray field, and the thermal switch protects against overload. Units ship pre-wired with shield ground terminal, and multiple secondary windings are available for custom applications. The transformer is enclosed in a steel cabinet that itself provides additional EMI shielding around the winding assembly.

Technical Specifications

Power rating 5 kVA, primary 230 V AC, secondary 230 V AC, frequency 50 or 60 Hz, electrostatic shield to PE, insulation class B, isolation voltage 4000 V AC, leakage current below 0.1 mA shielded, efficiency above 97 percent, no-load current below 3 percent, thermal protection included, enclosure IP20, mounting floor or wall, dimensions 320 by 260 by 280 mm, weight 45 kg, CE, UL, RoHS.

Performance Curve

The inter-winding capacitance is below 100 pF, reducing common-mode noise transfer by more than 80 dB at 1 MHz. Efficiency remains above 97 percent across 50 to 100 percent load. The shielded design limits earth leakage current to below 0.1 mA, satisfying medical IT requirements.

Applications

The transformer is used in medical IT systems in operating theatres and intensive care units, laboratory power supplies, audio and video production reference feeds, and sensitive test instrument isolation. It is also specified in IT installations requiring galvanic separation between building earth and equipment safety earth to eliminate ground loops and reduce conducted susceptibility.

In operating theatres, the transformer powers all medical outlets on the isolated IT circuit, and monitoring systems detect insulation faults before they become safety hazards. In broadcast studios, it isolates studio equipment from building power noise, eliminating ground loops in audio feeds. In research labs, it powers sensitive measurement instruments that must float relative to building earth.

Data center builders use it to isolate server racks from building ground potential differences. Audio equipment manufacturers use it on reference preamplifier power supplies. Industrial test labs use it on calibration equipment that requires a clean, isolated reference.

Advantages and Features

The shielded design cuts inter-winding capacitance to below 100 pF, dramatically reducing high-frequency common-mode noise transfer. The toroidal or laminated construction offers low magnetic stray field, and the thermal switch protects against overload. Units ship pre-wired with shield ground terminal, and multiple secondary windings are available for custom applications.

The steel enclosure provides additional shielding around the windings, reducing radiated magnetic field emissions. The isolated secondary can be grounded at a single point, eliminating ground loops between equipment. The thermal switch trips before damage occurs and resets after cooling. Mounting feet allow floor or wall installation depending on space.

Installation and Maintenance

Mount the transformer on a flat rigid surface, keep primary and secondary wiring in separate conduits, and bond the electrostatic shield to the designated PE bar with a short, thick conductor. Verify isolation resistance before energizing. Inspect terminals annually in medical installations and perform dielectric testing every two years. No routine maintenance is required for the windings themselves.

In medical IT installations, pair the transformer with an insulation monitoring device that alarms on ground faults. Keep the isolated secondary wiring physically separated from primary wiring to maintain isolation. Record leakage current readings at commissioning and trend them annually. In dusty environments, vacuum the cooling fins annually.

Packaging and Lead Time

Transformers ship on pallets with corner protection. Standard models have a 3-week lead time, and custom secondary voltages add 1 week. Medical-grade versions with full IEC 60601 test reports add 1 week.

Quality and Warranty

Each transformer undergoes hipot testing, insulation resistance measurement, and partial discharge testing. The 5-year warranty covers winding and enclosure integrity. Application engineering support is available for medical IT circuit design.

Compliance and Documentation

Isolation transformers are supplied with hipot test reports, partial discharge measurements, and IEC 60601 compliance documentation for medical models. The installation manual covers shield bonding, insulation monitoring device pairing, and dielectric test intervals. Application engineering support is available for medical IT circuit design and leakage current calculations.

Price

From $680 per piece. Contact +86 13922289957 for medical isolation transformer pricing.