KITOZER Jockey Pump: 1L/s @ 60m Pressure Maintenance Pump

Product Overview

The KITOZER 1 liter per second @ 60 meter jockey pump is a small centrifugal pressure maintenance pump installed in parallel with the main fire pump to compensate for small leaks and thermal expansion in the sprinkler and hydrant ring main. By keeping the system pressure above the main pump start threshold at all times, the jockey pump prevents unnecessary starts of the large electric or diesel fire pump, extends pump life, and eliminates false alarms triggered by minor pressure fluctuations. The unit includes a pressure tank, pressure switch set, and a compact vertical inline pump that fits easily in tight pump rooms.

Without a jockey pump, a main fire pump rated at 50 liters per second could start several times per day due to minor packing gland weeping, flange seepage, or thermal expansion in trapped water. Each start wears the large motor contactor, consumes electrical inrush current, and disturbs the ring main pressure. The jockey pump handles these small flows quietly and efficiently, so the main pump remains idle until a real fire opens multiple heads or breaks a pipe. The result is a much more reliable fire system that passes annual fire authority inspections without nuisance start concerns.

Technical Specifications

Rated flow 1 liter per second (3.6 cubic meters per hour), rated head 60 meters, motor power 1.5 kW, single phase 220V or three phase 380V, speed 2900 rpm, suction and discharge connection DN25, maximum working pressure 1.6 MPa, NPSHR 2.0 meters, impeller stainless steel 304, pump housing cast iron, mechanical seal silicon carbide, integrated 24 liters diaphragm pressure tank, pressure switch adjustable 4 to 8 bar, IP54 motor, Class F insulation. CCCF certified, ISO 9001.

The pump is a vertical inline multistage design, with two or three impellers stacked on a common shaft to build 60 meters of head in a compact body. The motor flange is bolted directly to the pump head, so there is no coupling to align. The mechanical seal is a balanced single seal suitable for cold clean water, with no flush required. The pressure switch is a dual-contact model with adjustable cut-in and cut-out, and it is wired directly to the pump contactor. The diaphragm tank is factory pre-charged and pressure tested, and the complete unit ships on a small steel base with isolating valves on suction and discharge.

Application Scenarios

This jockey pump is used in every automatic sprinkler and hydrant system where pressure losses from packing gland weepage, flange seepage, or minor thermal expansion could otherwise trigger the main pump several times per day. Typical installations include commercial buildings, office towers, hotels, hospitals, underground parking, data centers, factories, warehouses, and residential towers. The pump pairs with main pumps ranging from 10 liters per second to 100 liters per second, and can be added to existing systems as a retrofit to reduce nuisance starts and prolong motor winding life.

For smaller sprinkler systems below 10 liters per second main pump, the same jockey pump often serves as the only pressure maintenance device, with no separate pressure tank needed. For larger systems, two jockey pumps may alternate duty, providing redundancy if one seal fails. In high-rise towers, jockey pumps are installed at each pressure zone, maintaining pressure in the roof tank and in the mid-level booster zone. KITOZER offers jockey pumps in flow ratings from 0.5 liters per second to 5 liters per second, and head ratings from 30 meters to 120 meters, to match every main pump model in the range.

Key Advantages

The vertical inline design requires less than 0.2 square meters of floor space and connects directly to horizontal piping without elbow adapters. The stainless steel impeller resists corrosion from softened or treated water, and the canned mechanical seal eliminates weeping along the shaft. The diaphragm pressure tank is pre-charged at the factory, reducing on-site commissioning time. KITOZER also supplies a matched pressure switch and pressure gauge set calibrated to the project setpoint, so the contractor does not need to source components separately and risk mismatched cut-in and cut-out pressures.

The multistage impeller design delivers smooth, low-vibration operation compared with single-stage pumps trying to build 60 meters of head. The pump motor uses permanent split capacitor design for quiet operation in occupied buildings, and the vertical inline orientation means the pump can be mounted directly in the piping, reducing pipe stress. The integrated pressure tank smooths out short pressure dips that would otherwise start and stop the pump too frequently. KITOZER tests every pump on a closed loop test rig before shipment, verifying flow, head, current draw, and seal integrity, and ships each unit with a test certificate.

Installation and Maintenance Recommendations

Install the jockey pump on the discharge side of the main pump header, after the check valve, so it maintains pressure throughout the ring main. Set the pressure switch cut-out 0.5 to 1.0 bar below the main pump start pressure, and the cut-in 0.3 bar below the cut-out, to create a clear overlap. Check the pre-charge pressure of the diaphragm tank every six months by bleeding the air valve with a tire gauge, and recharge to the cold cut-in pressure. Inspect the mechanical seal annually and replace if weeping exceeds one drop per minute. Test automatic start by opening a small drain valve and confirming the jockey pump starts, runs, and stops cleanly.

Keep a strainer on the suction side of the jockey pump to catch debris that could score the precision mechanical seal. Isolate the pump with gate valves on suction and discharge, so the seal can be replaced without draining the entire ring main. Record the cut-in and cut-out pressures on the pump room log, and compare them monthly to detect slow drift in the pressure switch diaphragm. Spare parts recommended on site include a mechanical seal kit, a pressure switch, and an O-ring set. The pump warranty is 24 months, and KITOZER maintains stock of complete replacement units in Guangzhou for next-day dispatch.

Price

From $280 per set including pump, pressure tank, and pressure switch. Contact +86 13922289957 for jockey pump pricing.