The KITOZER 1 liter per second @ 60 meter jockey pump is a small centrifugal pressure maintenance pump installed in parallel with the main fire pump to compensate for small leaks and thermal expansion in the sprinkler and hydrant ring main. By keeping the system pressure above the main pump start threshold at all times, the jockey pump prevents unnecessary starts of the large electric or diesel fire pump, extends pump life, and eliminates false alarms triggered by minor pressure fluctuations. The unit includes a pressure tank, pressure switch set, and a compact vertical inline pump that fits easily in tight pump rooms.
Technical Specifications
Rated flow 1 liter per second (3.6 cubic meters per hour), rated head 60 meters, motor power 1.5 kW, single phase 220V or three phase 380V, speed 2900 rpm, suction and discharge connection DN25, maximum working pressure 1.6 MPa, NPSHR 2.0 meters, impeller stainless steel 304, pump housing cast iron, mechanical seal silicon carbide, integrated 24 liters diaphragm pressure tank, pressure switch adjustable 4 to 8 bar, IP54 motor, Class F insulation. CCCF certified, ISO 9001.
Application Scenarios
This jockey pump is used in every automatic sprinkler and hydrant system where pressure losses from packing gland weepage, flange seepage, or minor thermal expansion could otherwise trigger the main pump several times per day. Typical installations include commercial buildings, office towers, hotels, hospitals, underground parking, data centers, factories, warehouses, and residential towers. The pump pairs with main pumps ranging from 10 liters per second to 100 liters per second, and can be added to existing systems as a retrofit to reduce nuisance starts and prolong motor winding life.
Key Advantages
The vertical inline design requires less than 0.2 square meters of floor space and connects directly to horizontal piping without elbow adapters. The stainless steel impeller resists corrosion from softened or treated water, and the canned mechanical seal eliminates weeping along the shaft. The diaphragm pressure tank is pre-charged at the factory, reducing on-site commissioning time. KITOZER also supplies a matched pressure switch and pressure gauge set calibrated to the project setpoint, so the contractor does not need to source components separately and risk mismatched cut-in and cut-out pressures.
Installation and Maintenance Recommendations
Install the jockey pump on the discharge side of the main pump header, after the check valve, so it maintains pressure throughout the ring main. Set the pressure switch cut-out 0.5 to 1.0 bar below the main pump start pressure, and the cut-in 0.3 bar below the cut-out, to create a clear overlap. Check the pre-charge pressure of the diaphragm tank every six months by bleeding the air valve with a tire gauge, and recharge to the cold cut-in pressure. Inspect the mechanical seal annually and replace if weeping exceeds one drop per minute. Test automatic start by opening a small drain valve and confirming the jockey pump starts, runs, and stops cleanly.