KITOZER KTR-AIC-12K Air-Cooled Integrated Cabinet for Edge Data Centers

Product Overview

The KITOZER KTR-AIC-12K Air-Cooled Integrated Cabinet is a pre-engineered, factory-tested micro data-center solution that combines server rack, rear-door heat exchanger, precision airflow, monitoring, and power distribution into a single plug-and-play enclosure. Designed for small-to-medium server rooms, branch offices, and edge computing sites, the KTR-AIC-12K removes the need for a dedicated HVAC retrofit and can be operational within hours of delivery.

Technical Features

  • Rear-door active cooling module with 12 kW heat rejection at delta-T 10 K
  • N+1 redundant fan tray with EC variable-speed blowers
  • Integrated PDU (32A, 3-phase) with metered branch circuits
  • Rack-mounted smart controller: temperature, humidity, leak, smoke, door sensors
  • Front and rear perforated doors (75% open area) for optimal air exchange
  • Compatible with liquid-cooled rear-door upgrade field kit

Specifications

Parameter Value
Model KTR-AIC-12K
Rack Size 42U, 800×1200 mm
Cooling Capacity 12 kW (air-cooled rear door)
Airflow 4,000 m³/h, EC fans
Power Input 380 VAC 3-phase 50 Hz, 32A
Noise ≤ 68 dB(A) at 1 m
Operating Temp +18°C to +27°C (regulated)
Enclosure SPCC steel, RAL7035
Weight ~380 kg (empty)

Reference Price

Reference price: USD 6,800 – 8,200 per cabinet. Approx. CNY: RMB 49,000 – 59,000 (1 USD ≈ 7.2 CNY). Includes factory test report and commissioning guide.

Application Scenarios

  • Branch-office server rooms up to 15 kW IT load
  • Retail and finance edge computing nodes
  • Healthcare and small-medical imaging rooms
  • Education campus equipment closets

Installation & Maintenance

Level the cabinet on a flat floor, connect main power to the integrated PDU, and link the monitoring port to site LAN. No external ductwork is required. Quarterly: clean fan inlet filters, verify setpoint drift, and backup controller configuration.

FAQ

Q: Can I add a second cabinet later?
A: Yes, all KTR-AIC models support side-by-side clustering and shared cold-aisle containment kits.

Q: What is the MTBF?
A: Rear-door fan MTBF > 60,000 hours at 40°C ambient.

Industry Trends

Integrated air-cooled cabinets are gaining share in edge deployments where traditional CRAC units are uneconomical. Customers favor pre-integrated units that ship with warranty, BMS integration, and cybersecurity baseline settings already configured.

Delivery & Service

FOB Shenzhen. Warranty: 3 years on cabinet structure, 2 years on cooling module and controller. On-site install support available in China, Southeast Asia, and the Middle East.

Additional Notes

Drawing files (DWG, Revit) and sample BOM provided on request. Price excludes freight, installation labor, and site power cabling.