Table of Contents
ToggleKITOZER KTR-AOS-160 Compressed-Air Coalescing Oil Separator (DN25)
Brand: KITOZER Series: KTR-AOS-160 Category: Air-treatment / Oil Separator
CoalescingDN251.6 m3/minOil <=0.01 mg/m3KTR-AOS-160
1. Overview
The KITOZER KTR-AOS-160 is a coalescing compressed-air oil separator installed downstream of an oil-injected screw air compressor. It removes lubricating-oil mist, liquid oil droplets and solid particles carried by the compressed air. Oil-injected compressors spray screw oil into the airend for sealing and cooling, and the discharge typically carries 3 to 5 mg/m3 of oil aerosol. Left unremoved, this oil travels through the air network into pneumatic tools, cylinders, paint booths, food-filling lines and medical points, causing oily workpieces, sticking valves, paint-crater defects and product contamination. KTR-AOS-160 uses a glass-fiber coalescing element: as air passes through, sub-micron oil droplets are captured by the fibers and coalesced into larger drops, which fall by gravity to the sump and are discharged by an auto float drain.
Key specs: DN25 (G1 female) ports; rated flow 1.6 m3/min; working pressure 0.8 to 1.3 MPa; when inlet oil is up to 5 mg/m3, outlet residual oil drops to 0.01 mg/m3; filtration rating 0.01 um; initial pressure drop <=0.02 MPa; element replacement is recommended when delta-P reaches 0.07 MPa. The housing is anodized aluminum, light and corrosion-resistant, suitable for wall-mounting or upright pipe installation. The bottom port is fitted with an auto float drain that empties condensate when the compressor stops.
Typical layout: a pre-filter (cyclonic / main-line filter for water and coarse particles) right after the compressor, then KTR-AOS-160 coalescing oil separator, then a refrigerated or desiccant dryer, and finally a super-polishing filter at the point of use. This three-stage arrangement keeps residual oil below 0.01 mg/m3, meeting requirements of paint booths, bottle-blowing, food packaging and electronics clean rooms.
2. Key Features
Glass-fiber coalescing element
- Multi-layer graded-density glass fiber.
- Sub-micron droplets coalesce into liquid.
- Outlet oil <=0.01 mg/m3.
- Rating 0.01 um.
Auto float drain
- Empties condensate on shutdown.
- Zero air-loss design.
- Manual test screw on the drain.
- Transparent extension tube available.
Anodized aluminum housing
- Lightweight, easy wall-mounting.
- Corrosion-resistant for humid plants.
- Rated to 1.6 MPa.
- Symmetric ports for flexible plumbing.
Differential-pressure indicator
- Optional gauge on top.
- Green = ok, red = replace element.
- Element life typically 3000~4000 h.
- No need to open the housing to inspect.
3. Specifications
| Item | Value |
|---|---|
| Model | KTR-AOS-160 |
| Type | Coalescing compressed-air oil separator |
| Port size | DN25 (G1 female) |
| Rated flow | 1.6 m3/min |
| Working pressure | 0.8~1.3 MPa |
| Max pressure | 1.6 MPa |
| Inlet oil content | <=5 mg/m3 |
| Outlet residual oil | <=0.01 mg/m3 |
| Filtration rating | 0.01 um |
| Initial pressure drop | <=0.02 MPa |
| Replacement delta-P | 0.07 MPa |
| Operating temperature | 1.5~60 C |
| Housing | Anodized aluminum |
| Element media | Glass-fiber coalescing layer |
| Drain | Auto float drain |
| Mounting | Vertical (drain down) |
4. Reference Price
KTR-AOS-160 complete unit (element + auto drain): RMB 320~460 / unit (about USD 45~64)
KTR-AOS-300 high-flow (3.0 m3/min, DN40): RMB 520~720 / unit (about USD 72~100)
KTR-AOS-080 small (0.8 m3/min, DN20): RMB 240~340 / unit (about USD 33~47)
Spare coalescing element (0.01 um): RMB 120~180 / pc (about USD 17~25)
Auto float drain (spare): RMB 45~75 / pc (about USD 6~10)
Differential-pressure gauge (optional): RMB 35~55 / pc (about USD 5~8)
Reference prices only; final price subject to quotation. (1 USD ≈ 7.2 CNY)
5. Applications
- Downstream of oil-injected screw compressors.
- Main air lines in paint booths.
- Air supplies for bottle blowers and filling lines.
- SMT lines and lab instruments in electronics plants.
- Clean air for medical devices and pharma.
- Centralized supply for pneumatic tools and cylinders.
- Front-end filtration for lithium / PV process gas.
6. Installation & Maintenance
Installation
- Mount after the compressor, before the dryer.
- Upright, drain pointing down.
- Follow the arrow on the housing; do not reverse.
- Install ball valves on both sides for element change without shutdown.
- Run a transparent tube from the drain to a sump.
- Use a wrench on the hex flats, not on the bowl.
- Pressurize to 0.8 MPa and soap-test fittings.
- Confirm the gauge starts in the green zone.
Maintenance
- Check the auto drain cycles once a day.
- Manually test the drain valve weekly.
- Record the delta-P monthly.
- Replace element at 0.07 MPa or 3000~4000 h.
- Close inlet/outlet valves and fully vent before opening.
- Dispose of used oil-soaked elements as hazardous waste.
- Wash the bowl annually with diesel or cleaner.
- Add a heat trace on the drain when ambient <2 C.
7. FAQ
- Q:Can I mount KTR-AOS-160 right at the compressor outlet?
A:Not recommended. Compressor discharge is hot (80~100 C) and carries bulk liquid water and sludge, which would clog the coalescing element fast. Fit a cyclonic / main-line pre-filter first, then KTR-AOS-160, so inlet air is below 60 C. - Q:Why is there still oil mist at the outlet?
A:Three common causes: element overdue (high delta-P); O-ring aged or not seated, causing bypass; pre-filter failed, so bulk liquid oil floods the coalescer beyond its capacity. Check the gauge first, then the O-ring, then the pre-filter. - Q:The auto drain leaks air constantly.
A:Usually the float seal is propped open by debris (rust, sludge). Rinse the float and seat with clean water; do not sand them. If it still leaks, replace the drain (about RMB 45~75). Do not substitute a solenoid timer drain; the principle is different. - Q:How often should I change the element?
A:Go by delta-P: replace at 0.07 MPa from an initial 0.02 MPa. In clean plants with a healthy compressor this is 3000~4000 h; in dusty plants with an ageing, oil-passing compressor it may block in 1500 h. Use the gauge, not a calendar.
8. Industry Trends & Selection
Compressed-air treatment is moving from single filters to integrated multi-stage skids that combine pre-filtration, coalescing, super-polishing and drying. Zero-air-loss drains replace timer solenoids to save energy. Regulated industries (paint, food, pharma) increasingly demand ISO 8573-1 Class 0 oil content, pushing media toward higher-grade glass fiber. Select by flow and air-quality class: paint booths need Class 1 (0.1 mg/m3); food and pharma need Class 0 (0.01 mg/m3); the KTR-AOS range covers both. If the compressor starts passing more oil, upsize the pre-filter rather than asking the coalescer to cope alone.
9. Delivery & Service
KITOZER sizes KTR-AOS separators by compressor displacement and required air-quality class, and provides piping drawings plus a three-stage layout. Delivery includes the unit (with element), auto drain, mounting bracket, manual and certificate. On-site installation guidance and element-change training are covered under warranty.
10. Notes
A common pitfall is skipping the pre-filter. Connecting the coalescer directly to the compressor outlet lets bulk liquid oil and water soak the element within a month and spike the delta-P. Remember: the coalescer handles mist, not liquid; bulk water and oil must be removed upstream by a cyclonic pre-filter.
Another pitfall is opening the bowl without venting. Closing the inlet/outlet valves does not release the 0.8 MPa still trapped inside; the element can shoot out like a bullet when the bowl is loosened. Fit a vent valve at the bottom and confirm the gauge reads zero before opening.
Selection summary: coalescing; DN25; 1.6 m3/min; residual oil <=0.01 mg/m3; auto drain. The coalescer is the heart of air treatment; the keys are proper upstream water removal, watching the delta-P, and venting before element change.
Tip: on newly piped systems, iron chips and welding slag will flush out. Run a temporary coarse filter for a week before removing it, otherwise this debris will puncture the glass-fiber media and cause internal bypass.
SEO
Contact Us
KITOZER brand (professional data-center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com