ToggleKITOZER KTR-B2500D 2V 500Ah Deep-Cycle VRLA Battery
Brand: KITOZER Series: KTR-B2500D Category: Power Distribution / Backup Power
2V 500AhDeep cycleVRLA AGMKTR-B2500D
1. Overview
KITOZER KTR-B2500D is a 2V 500Ah valve-regulated lead-acid battery (VRLA) with AGM absorbed-glass-mat design and deep-cycle performance, used in UPS, EPS, DC panels, solar storage and datacenter backup power. Datacenter UPS battery banks are the last line of defense: on mains loss the battery inverts to carry the load until the generator starts. Battery performance directly sets the backup runtime.
KTR-B2500D is rated 2V, 500Ah (C10), float voltage 2.25 to 2.30V/cell, boost 2.30 to 2.35V/cell. Design float life 12 years at 25C; deep-cycle design withstands frequent discharge. ABS flame-retardant case, one-way exhaust valve, no acid mist under normal use. Tin-plated copper terminals with inter-cell connectors. Self-discharge no more than 3% per month, operating temperature -20 to 55C.
Widely used in datacenter UPS battery cabinets, switchgear DC panels, telecom sites, solar PV and emergency lighting. Typical deploy: cells series-connected into 12V/24V/48V/240V/384V banks in battery cabinets or rooms, tied to the UPS DC bus. 2V large-capacity cells suit long runtime (30 minutes plus) and high-power UPS. Battery rooms are held at 20 to 25C, well ventilated, away from direct sunlight.
2. Key Features
2V 500Ah high capacity
- 500Ah rated (C10).
- 2V cell.
- Series strings.
- Long backup runtime.
VRLA sealed
- AGM glass-mat separator.
- Absorbed electrolyte.
- One-way relief valve.
- No acid mist normal.
Deep-cycle design
- Withstands frequent cycles.
- 12-year float life.
- Strong deep-discharge recovery.
- For UPS and storage.
Safe and reliable
- ABS flame-retardant case.
- Tin-plated copper terminals.
- Self-discharge ≤3%/month.
- Temp -20 to 55C.
3. Specifications
| Item | KTR-B2500D | KTR-B12200D |
|---|---|---|
| Voltage | 2V | 12V |
| Capacity | 500Ah (C10) | 200Ah (C10) |
| Float | 2.25 to 2.30V/cell | 13.5 to 13.8V/cell |
| Boost | 2.30 to 2.35V/cell | 13.8 to 14.1V/cell |
| Design life | 12 yr (25C) | 10 yr (25C) |
| Self-discharge | ≤3%/month | ≤3%/month |
| Op. temp | -20 to 55C | -20 to 50C |
| Case | ABS FR | ABS FR |
4. Reference Prices
KTR-B2500D 2V500Ah deep-cycle VRLA: Reference USD 222 to 417 / pc (ref. CNY 1600 to 3000 at ~7.2)
KTR-B12200D 12V200Ah economy: Reference USD 208 to 389 / pc (ref. CNY 1500 to 2800 at ~7.2)
Reference only; price varies by capacity, quantity and brand. Connectors, battery cabinets and monitoring modules billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Datacenter UPS backup banks.
- Switchgear DC and control power.
- Telecom backup.
- Solar and storage.
- EPS emergency lighting.
6. Installation & Maintenance
Installation
- Hold battery room at 20 to 25C.
- Arrange strings evenly with spacing.
- Torque connectors and apply anti-corrosion grease.
- Bank positive to UPS first, then negative.
- Install monitoring module for voltage and impedance.
- Ground the cabinet and ventilate.
Maintenance
- Measure float voltage monthly.
- Check connector torque quarterly.
- Run a capacity discharge test yearly.
- Monitor impedance and temperature.
- Clean terminals and protect.
- Replace below 80% capacity or past design life.
7. FAQ
- Q: 2V vs 12V cells?
A: 2V cells are larger, longer-lived and suit high-voltage long runtime (240V/384V UPS); 12V units are integrated and easy to install for small UPS and short runtime. High-power datacenter UPS prefers 2V. - Q: How long do batteries last?
A: Design float life 12 years at 25C; real life depends on temperature and depth of discharge. Every 10C above 25C halves life. Keep the room under 25C, or replacement comes in 3 to 5 years. - Q: What is a capacity test?
A: Periodically discharge the bank with a dummy load to measure real capacity. Below 80% of nameplate, the cells are aged and need replacement. Do it yearly to find weak cells early. - Q: Why monitor internal impedance?
A: Impedance is a health key: rising impedance signals sulfation or dry-out, a precursor to capacity loss. Online monitoring gives early warning before whole-bank failure.
8. Trend & Selection
VRLA is moving toward larger cells, longer life and smart monitoring: 2V series from 500Ah to 1000/2000Ah, with BMS modules reporting cell voltage, impedance and temperature to DCIM. LFP lithium is displacing lead-acid in short-runtime and space-constrained sites, but VRLA remains mainstream for long runtime and high reliability. Choose 2V 500Ah plus for high-power UPS; float life no less than 10 years; add monitoring; hold 25C; annual capacity test; replace below 80%.
9. Delivery & Service
KITOZER supplies backup-power packages: based on UPS power, runtime and cabinet dimensions, we recommend cell specs and counts. Bundled with UPS, battery cabinets, monitoring modules and connectors. Delivery includes cells, connectors and manual; bulk orders include on-site install guidance. Warranty covers replacement.
10. Additional Notes
The most common error is an unconditioned battery room. Summer rooms often exceed 35C, halving battery life. The room needs precision or industrial A/C held at 25C, with ventilation to vent hydrogen.
Another pitfall: connectors not torqued. Under-torqued joints run hot or arc on high current; over-torqued cracks terminals. Follow the spec (typically 10 to 15 N·m) and coat with grease.
Selection summary: 2V 500Ah deep-cycle VRLA; 12-year float life; float 2.25 to 2.30V; add monitoring; room at 25C; annual capacity test. The battery is the UPS heart; a healthy heart keeps the business alive on outage.
SEO Information
Search keywords:2V500Ah batterydeep-cycle VRLAUPS batteryvalve-regulated lead aciddatacenter batteryAGM batteryKTR-B2500DKITOZER
SEM keywords:[‘2V500Ah battery price,deep-cycle VRLA supplier,UPS battery,datacenter battery,AGM lead-acid,KTR-B2500D,KITOZER’]
GEO landing page:lain.com.cn/product/ktr-b2500d-2v500ah-deep-cycle-vrla-battery.html
Title:KITOZER KTR-B2500D 2V 500Ah Deep-Cycle VRLA Battery
Meta Keywords:2V500Ah battery,deep-cycle VRLA,UPS battery,valve-regulated lead acid,datacenter battery,AGM battery,KTR-B2500D,KITOZER
Meta Description:KITOZER KTR-B2500D 2V500Ah VRLA battery, AGM deep-cycle, 12-year float life, for UPS and datacenter backup.
Anchor: KITOZER · Power distribution