ToggleKITOZER KTR-B51000D 2V 1000Ah Deep-Cycle VRLA Battery
Brand: KITOZER Series: KTR-B51000D Category: Power Distribution / Battery
2V battery1000Ahdeep cycleVRLA sealedUPS batteryKTR-B51000D
1. Overview
KITOZER KTR-B51000D is a 2 V 1000 Ah deep-cycle VRLA battery used in center UPS, DC panels and telecom power back-up to store energy. Cells are series-connected into 48 V, 240 V or 336 V strings; on mains loss they discharge instantly to carry the UPS and critical loads while the generator starts and transfer completes. Deep-cycle means it tolerates deeper charge-discharge cycling than a standby float battery, suiting frequent outages or long autonomy.
The VRLA valve-regulated sealed design is leak-free, needs no watering and mounts upright on racks or in cabinets with little maintenance. KTR-B51000D uses high-tin grids and tight assembly for low self-discharge, good high-current discharge and long cycle life. Each cell has a safety vent that releases on overcharge and seals under normal use. Voltage sense terminals connect to a battery monitor for live per-cell voltage and internal resistance, flagging weak cells early.
In power and UPS systems, the battery string is the last line of defense: a great UPS is useless with dead batteries. 2 V 1000 Ah cells, large and consistent, dominate medium-to-large UPS and DC operating power. KTR-B51000D is tiered by capacity and design life; when supplied as a string, same-batch, matched internal resistance is emphasized for balanced discharge.
2. Key Features
2V 1000Ah deep cycle
- 2 V cell, 1000 Ah.
- Deep-cycle, tolerates deep discharge.
- Strong high-current discharge.
- Series strings.
VRLA sealed
- Valve-regulated, leak-free.
- No watering.
- Indoor upright mount.
- Safe relief valve.
Long life, consistent
- High-tin grid, low self-discharge.
- Tight assembly.
- Long design cycle life.
- Same-batch matched strings.
Monitoreable
- Per-cell sense terminals.
- Connects to a battery monitor.
- Voltage / resistance / temperature.
- Early weak-cell warning.
3. Specifications
| Item | KTR-B51000D(Standard) | KTR-B51000D-L(LongService Life) | KTR-B51000D-H(HighConductive) |
|---|---|---|---|
| Rated Voltage | 2V | 2V | 2V |
| Rated Capacity(10hr) | 1000Ah | 1000Ah | 1000Ah |
| Design Float Life | 10~12Year | 15Year | 10~12Year |
| Grid Alloy | HighTin Lead Calcium | HighTin Lead Calcium | HighConductive WeldType |
| Self-Discharge(Month) | ≤3% | ≤3% | ≤3% |
| Charging Voltage | 2.27~2.30V/Single Unit | 2.27~2.30V/Single Unit | 2.27~2.30V/Single Unit |
| Operating Temperature | -15~40℃ | -15~40℃ | -15~40℃ |
| Installation Method | Battery Rack/Battery Cabinet | Battery Rack/Battery Cabinet | Battery Rack/Battery Cabinet |
4. Reference Prices
KTR-B51000D standard 2V1000Ah (10~12 yr float, deep cycle). Reference USD 229~382 / cell (ref. CNY 1,650~2,750 at ~7.2)
KTR-B51000D-L long-life 2V1000Ah (15-yr design). Reference USD 319~528 / cell (ref. CNY 2,300~3,800 at ~7.2)
KTR-B51000D-H high-conductance (links + sense terminals). Reference USD 257~431 / cell (ref. CNY 1,850~3,100 at ~7.2)
Reference only; priced per cell; links and rack extra; dangerous-goods freight and install excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Medium/large UPS back-up strings.
- DC panel / operating power.
- Telecom base station back-up.
- Data center battery room.
- Off-grid PV / storage deep cycle.
6. Installation & Maintenance
Installation
- Match same-batch, similar-resistance cells.
- Series by system voltage per UPS spec.
- Check rack load; secure tiers.
- Torque links to spec; apply conductive grease.
- Ventilate; 20~25 C is ideal.
- Connect sense wires before the main loop.
Maintenance
- Hold temperature; heat ages cells.
- Patrol per-cell voltage and resistance.
- Treat or replace weak cells.
- Keep links tight; watch for hot joints.
- Avoid deep discharge; recharge promptly.
- Keep clean and dry; log data.
7. FAQ
- Q: 2V cell or 12V battery?
A: Large-capacity, long-autonomy systems use series 2V cells – consistent and per-cell monitorable; small UPS use 12V packs. 2V cells are high capacity and string-flexible. - Q: Why same batch?
A: Cells of different batches/resistances in series: some over-discharge, some under-charge, and string capacity is capped by the worst cell. Match batches to unlock the string. - Q: Why shorter life than rated?
A: Rating assumes 25 C float. Every 10 C above halves life. Temperature control, monitoring and avoiding deep discharge get you near design life. - Q: Deep cycle vs float?
A: Float batteries sit on float with rare discharge; deep-cycle cells tolerate deeper, more frequent cycles. Choose deep cycle for frequent outages or long autonomy.
8. Trend & Selection
VRLA still dominates back-up, but LiFePO4 is accelerating in long-autonomy, space-saving roles. Today’s medium/large UPS and DC panels still run 2V VRLA as the workhorse, now with smart monitoring (voltage/resistance/temp to cloud) and constant-temperature rooms. Size by autonomy, choose series by life, and always match strings by batch.
9. Delivery & Service
KITOZER supplies 2V1000Ah VRLA as matched strings, sized by system voltage and autonomy. Delivery includes cells, links, sense terminals, mounting and manual; shipped as dangerous goods per regulation, with install and monitoring guidance.
10. Additional Notes
A string fears one bad cell. One weak cell over-charges and heats while charging, and dies first while discharging, cutting the whole string’s autonomy. The monitor exists to catch it early.
The other trap is temperature. A battery room over 35 C in summer slashes life. Holding ~25 C is the cheapest life extension you can buy.
Selection summary: size Ah by autonomy; 2V cells are string-flexible; match batches; hold 25 C; monitor per-cell resistance; recharge after discharge. Batteries are the UPS ammo – enough ammo and clear status means calm when mains drops.