ToggleKITOZER KTR-BAT-LFP48100 48V 100Ah Rack LiFePO4 Battery (5 kWh)
Brand: KITOZER Series: KTR-BAT-LFP48100 Category: Battery / LiFePO4 Rack
48V 100Ah5 kWhLiFePO4BMSKTR-BAT-LFP48100
1. Overview
The KITOZER KTR-BAT-LFP48100 is a 48 V 100 Ah rack-mount LiFePO4 storage battery with 5.12 kWh capacity, designed to replace the traditional 48 V lead-acid string used in telecom towers and data centers (typically 16 x 12 V 100 Ah lead-acid in series, weighing about 500 kg). KTR-BAT-LFP48100 integrates 16 cells of 3.2 V LiFePO4 into a 3U rack enclosure with a built-in battery management system (BMS), weighing about 45 kg (one-tenth of the lead-acid string) at 440x550x133 mm (3U). It slides into a standard server rack and replaces the old lead-acid rack.
Key specs: nominal 51.2 V (16S 3.2 V), 100 Ah, 5.12 kWh; cycle life 6000 (80% DOD), 12 times the 500-cycle lead-acid; operating temp -20 to +60 C; built-in BMS monitors cell voltage, temperature and current, with over-charge/discharge/temperature protection; RS485/CAN reports status to the UPS or EMCS; up to 16 parallel units (800 Ah, 40 kWh total); charge voltage 54.75 V, cut-off 44.8 V; max charge/discharge current 100 A (1C).
Typical uses: 48 V backup power at telecom towers (replacing lead-acid strings); UPS battery strings in data centers; industrial/commercial storage cabinets (parallel racks to tens of kWh); residential PV storage; off-grid solar systems. Compared with lead-acid (KTR-BAT-VRLA12100 from the 846 line), LiFePO4 lasts 12x longer, weighs 90% less, is maintenance-free (no watering) and acid-free, but costs more (5 kWh at about 8000 to 12000 RMB vs a comparable lead-acid string at 5000 to 7000 RMB); over 10 years, LiFePO4 is cheaper.
2. Key Features
Long-life LiFePO4
- LiFePO4 cells, fire-safe chemistry.
- 6000 cycles (80% DOD).
- 10-year design life.
- 3x energy density of lead-acid.
Built-in BMS
- 16-cell balancing.
- Over-charge/discharge/current/temp protection.
- RS485/CAN status report.
- UPS integration.
Rack mount
- 3U, 19-inch rack.
- About 45 kg (two-person lift).
- Up to 16 parallel units.
- Plug-and-play with UPS.
Wide temp
- -20 to +60 C.
- Maintenance-free, no watering.
- No acid mist, eco-friendly.
- Low self-discharge (<=3%/month).
3. Specifications
| Item | Parameter |
|---|---|
| Model | KTR-BAT-LFP48100 |
| Type | Rack LiFePO4 battery |
| Nominal voltage | 51.2 V (16S 3.2 V) |
| Rated capacity | 100 Ah |
| Rated energy | 5.12 kWh |
| Charge voltage | 54.75 V |
| Discharge cut-off | 44.8 V |
| Max current | 100 A (1C) |
| Cycle life | 6000 (80% DOD, 25 C) |
| BMS | Built-in, voltage/temp/current protection, balance |
| Comm | RS485 / CAN |
| Parallel | up to 16 units |
| Operating temp | -20 to +60 C (charge 0 to +50 C) |
| Self-discharge | <=3% per month |
| Dimensions | approx. 440x550x133 mm (3U) |
| Weight | about 45 kg |
4. Reference Prices
KTR-BAT-LFP48100 48V100Ah 5.12 kWh (with BMS): Ref. USD 1111~1667 / unit (CNY 8000~12000 at 7.2)
KTR-BAT-LFP4850 48V50Ah 2.56 kWh: Ref. USD 625~903 / unit (CNY 4500~6500 at 7.2)
KTR-BAT-LFP512 51.2V 280Ah 14.3 kWh wall-mount: Ref. USD 2500~3611 / unit (CNY 18000~26000 at 7.2)
KTR-BAT-VRLA12100 12V100Ah lead-acid: Ref. USD 111~167 / pc (CNY 800~1200 at 7.2)
Parallel cable (50 mm2, 1 m): Ref. USD 11~21 / pc (CNY 80~150 at 7.2)
RS485 comm cable (3 m): Ref. USD 3.5~5.6 / pc (CNY 25~40 at 7.2)
Reference only; 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Telecom tower 48 V backup.
- Data center UPS strings.
- Commercial storage cabinets.
- Residential PV storage.
- Off-grid solar systems.
- Outdoor cabinet backup.
6. Installation & Maintenance
Installation
- Unpack; two people lift (45 kg); do not lift alone.
- Slide into a 3U rack space; fix front ears with screws.
- Set the main breaker to OFF.
- Connect positive/negative to the UPS DC bus with parallel cables (red +, black -).
- For parallel strings, tie first and last units to + and – bus bars.
- Connect RS485 to the UPS or EMCS.
- Close the breaker and power on.
- In the UPS UI, detect the battery; confirm BMS voltage and SOC.
Maintenance
- Monthly: read BMS SOC; keep 20 to 95%.
- Quarterly: check cell delta voltage (<=0.05 V).
- Wipe dust with a dry cloth.
- Keep the battery cabinet ventilated (25 C ideal).
- For long storage, recharge every 3 months at 50% SOC.
- Do not short positive and negative.
7. FAQ
- Q:LiFePO4 vs lead-acid?
A:For new builds with budget, choose LiFePO4 (KTR-BAT-LFP48100): 12x cycle life, light, maintenance-free, acid-free, cheaper over 10 years. For extending an existing lead-acid system, choose lead-acid (KTR-BAT-VRLA12100) and match the chemistry; never parallel LiFePO4 with lead-acid (different charge curves cause swelling). New telecom and data center projects prefer lithium. - Q:Can I reuse an old UPS?
A:Check UPS lithium support. Traditional lead-acid UPS charges at about 54 V (16 x 2.25 V), close to the 54.75 V LiFePO4 charge voltage, so many UPS units work directly. But the UPS discharge cutoff is often 43 V (lead-acid), while LiFePO4 cutoff is 44.8 V; set the UPS to lithium mode (cutoff 48 V). If the UPS cannot be reconfigured, the lithium string will be over-discharged. Confirm with the UPS vendor before purchase. - Q:How to parallel units?
A:Up to 16 units. Tie all positives to the UPS positive bus, all negatives to the negative bus. Use 50 mm2 cables of equal length (minimizes line-loss differences). The first and last units are farthest from the UPS; size the cables for voltage drop. Daisy-chain BMS comms with a terminator on the last unit. - Q:Battery swelling?
A:Swelling means internal gassing; stop using immediately. Causes: over-charge (charger runaway), high temp (cabinet >60 C), or cell defect. Do not keep charging a swollen pack; fire risk. Contact the vendor for replacement. Ensure cabinet ventilation and keep the interior at 25 C.
8. Trend & Selection
Backup power shifts from lead-acid to LiFePO4; new data center and telecom projects are over 50% lithium. Cells move to large-format (280 Ah / 314 Ah); per-rack energy rises from 5 kWh to 20 kWh. BMS moves from basic protection to smart management (cloud monitoring, SOH estimation). Integrated cabinets (battery + converter + EMS) spread in C&I storage. Recycling systems are being built.
9. Delivery & Service
KITOZER sizes KTR-BAT-LFP48100 by backup time and load, supplying parallel diagrams and RS485 register tables. Delivery includes battery, parallel cables, comm cable, manual and certificate. 5-year warranty covers BMS commissioning and capacity testing.
10. Additional Notes
A common pitfall is mixing lithium with lead-acid. Customers add new lithium on top of old lead-acid to save money. The charge curves differ (lithium constant-voltage 54.75 V vs lead-acid 54 V three-stage); over time lithium over-charges while lead-acid under-charges, causing swelling or sulfation. Use all lithium or all lead-acid; do not mix.
Another pitfall is missing insulation. Isolate the battery cabinet from the rack frame; a housing-to-frame short causes a fire. Add an insulating sheet under the battery and insulating boots on the terminals.
Selection summary: 48V100Ah; 5.12 kWh; LiFePO4; BMS; RS485. Lithium is the future of backup power; the keys are UPS lithium support, no lead-acid mixing, and adequately sized parallel cables.
Additional tip: every 10 C rise halves battery life. Vent the battery cabinet, add temp monitoring, and keep the interior under 25 C. In summer, route rack AC to the battery cabinet.