ToggleKITOZER KTR-BT-LFP12 12V100Ah LiFePO4 Battery (BMS, 5000 cycles)
Brand: KITOZER Series: KTR-BT-LFP12 Category: Energy Storage / LiFePO4 Battery
12V100AhBuilt-in BMS5000 cyclesLead-acid replacementKTR-BT-LFP12
1. Overview
The KITOZER KTR-BT-LFP12 is a 12V100Ah LiFePO4 (LFP) storage battery with a built-in battery management system (BMS). It uses 4-cell LFP (nominal 3.2V x 4 = 12.8V, full 14.6V) to replace traditional 12V100Ah lead-acid. Compared with item 862 (12V200Ah gel lead-acid), lead-acid is cheap (about CNY 800 to 1500) but short-lived (300 to 500 cycles), heavy (about 60 kg) and damaged by deep discharge. LFP is expensive (CNY 2500 to 3500) but long-lived (over 5000 cycles), light (about 12 kg), tolerant of deep discharge (can discharge low without swelling), and acid-leak-free. Despite higher unit price, over a 5-year cycle (lead-acid replaced every 2 years) LFP has lower total cost, and at one-fifth the weight it is far friendlier to rack loading.
Specs: nominal 12.8V (4S LFP); rated 100Ah (about 1.28 kWh); charge voltage 14.6V; discharge cutoff 10.0V; continuous charge/discharge 100A (1C); peak 200A (3 s); built-in BMS (over/under-voltage, over-current, short, temp protection); optional CAN/RS485; cycle life >=5000 (80% DOD, 25 C); charge 0 to +50 C, discharge -20 to +60 C; ABS/metal case; about 330x170x215 mm; about 12 kg; M8 terminals. Compared with NMC (3.7V x 4 = 14.8V), LFP has slightly lower energy density (bulkier per Ah) but is safer (no fire/explosion), longer-lived, and heat-tolerant—ideal for storage, UPS and solar.
Typical uses: UPS backup (lead-acid replacement); off-grid solar storage (PV + battery); RV/marine house batteries; wall-mount home storage; telecom base-station backup; solar-powered surveillance. A 1 kVA UPS with one KTR-BT-LFP12 backs up about 30 min at 1 kW load.
2. Key Features
5000-cycle long life
- LFP cells, 80% DOD.
- >=5000 cycles (25 C).
- 10x lead-acid (500 cycles).
- 5+ year service life.
Built-in BMS
- Over-charge (cell 3.65V).
- Over-discharge (cell 2.5V).
- Over-current / short.
- Charge/discharge temp.
Lightweight, high power
- About 12 kg (lead-acid ~30 kg).
- 1.28 kWh per unit.
- 100A continuous.
- M8 high-current terminals.
Optional comms
- CAN/RS485 optional.
- Integrates with UPS / EMS.
- Reports SOC/SOH.
- Passive cell balancing.
3. Specifications
| Item | Parameter |
|---|---|
| Model | KTR-BT-LFP12 |
| Chemistry | LiFePO4 (LFP) |
| Nominal voltage | 12.8V (4S) |
| Rated capacity | 100Ah (about 1.28 kWh) |
| Charge voltage | 14.6V |
| Discharge cutoff | 10.0V |
| Continuous current | 100A (1C) |
| Peak current | 200A (3 s) |
| BMS | Built-in (OCP/UV/OCD/OT) |
| Comms | CAN/RS485 (optional) |
| Cycle life | >=5000 (80% DOD, 25 C) |
| Operating temp | Charge 0 to +50 C; discharge -20 to +60 C |
| Dimensions | about 330x170x215 mm |
| Weight | about 12 kg |
4. Reference Prices
KTR-BT-LFP12 12V100Ah LFP (BMS): Ref. USD 347~486 / pc (CNY 2500~3500 at 7.2)
KTR-BT-LFP24 24V100Ah LFP: Ref. USD 667~944 / pc (CNY 4800~6800 at 7.2)
KTR-BT-LFP100 12V100Ah (CAN comms): Ref. USD 389~528 / pc (CNY 2800~3800 at 7.2)
KTR-BT-AGM100 12V100Ah lead-acid (compare): Ref. USD 83~125 / pc (CNY 600~900 at 7.2)
MPPT solar charge controller: Ref. USD 42~111 / pc (CNY 300~800 at 7.2)
Battery rack (4-bay): Ref. USD 28~56 / pc (CNY 200~400 at 7.2)
Reference only; 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- UPS backup (lead-acid replacement).
- Off-grid solar storage.
- RV / marine house batteries.
- Wall-mount home storage.
- Telecom base-station backup.
- Solar surveillance.
6. Installation & Maintenance
Installation
- Positive to UPS/inverter positive, negative to negative (do not reverse).
- Parallel/series: same model, batch and SOC.
- Series strings must match UPS (e.g., 4 in series = 48V).
- Torque terminals (8 to 10 Nm); coat with grease against oxidation.
- Leave 10 mm gap between batteries for cooling.
- Install in ventilated, dry place (not sealed enclosure).
- Charge fully (14.6V) before first use.
- If CAN comms, wire CAN to UPS.
- Do not mix with lead-acid (different charge curves).
Maintenance
- Quarterly check terminal tightness.
- Monthly review BMS SOC (if comms).
- Long storage: keep at 50% SOC, top up every 3 months.
- Do not store below 10V (BMS protects, but prolonged low-SOC storage damages cells).
- Do not charge below 0 C (lithium plating, permanent damage).
- Stop immediately if swelling, leakage or odor.
- Dispose as hazardous waste (Li-ion); do not discard.
7. FAQ
- Q:Can LFP directly replace lead-acid?
A:Same voltage class (12V to 12V) yes, but note three points: (1) charge voltage—LFP needs 14.6V; lead-acid charges to 13.8 to 14.4V, so a lead-acid UPS may undercharge LFP (use an LFP charger or set UPS to LFP mode); (2) charge current—LFP accepts 1C, lead-acid usually 0.1C, so the UPS charge board may not match; (3) comms—if the UPS expects battery comms (SOC reporting), choose the CAN/RS485 LFP model. - Q:How many can be paralleled?
A:Same model/batch in parallel, typically 4 to 8 (each BMS independent, current sharing). More parallel units raise single-point-failure impact. Beyond 8, use a centralized BMS cabinet. Never mix old and new (old internal resistance drags new cells). - Q:Can LFP discharge in winter?
A:Discharge range -20 to +60 C, but capacity drops at low temp (about 70% at 0 C, 50% at -20 C). Charging must be above 0 C (low-temp charging causes lithium plating and permanent damage). Insulate or add heating for outdoor winter use. - Q:Is LFP safe? Can it catch fire?
A:LFP is thermally more stable than NMC—nail penetration and crushing do not cause fire or explosion; it is the safest Li-ion chemistry. But BMS failure (overcharge) or short circuit can still trigger thermal runaway; the built-in BMS prevents over/under-voltage. With proper use and genuine product, fire risk is extremely low.
8. Trend & Selection
Storage batteries are shifting from lead-acid to LFP (lower 5-year cost, lighter). Units move from bare cells to BMS-equipped smart batteries with comms. Systems evolve from 12V to 48V for higher efficiency. Home storage moves from wall-mount to stackable. Off-grid solar moves from lead-acid + controller to LFP + MPPT integrated. Size by backup time: power x time / voltage / efficiency. LFP can use 80% DOD vs lead-acid’s 50%, so LFP capacity can be halved for the same runtime.
9. Delivery & Service
KITOZER sizes KTR-BT-LFP batteries by UPS power and backup time, providing cell-count calculations and series/parallel wiring guidance. Delivery includes battery, terminal bolts, manual, certificate. Warranty covers BMS commissioning and charger matching advice.
10. Additional Notes
A common pitfall is charging LFP with a lead-acid charger. Lead-acid charges to 13.8 to 14.4V; LFP needs 14.6V to be full. A lead-acid charger leaves LFP at 80% SOC and wastes capacity. Switch to an LFP charger or set UPS charge voltage to 14.6V.
Another pitfall is parallel mixing of old and new cells. High internal resistance in old cells causes new cells to charge them, dragging the whole string down. Replace the whole string at once.
Selection summary: 12V100Ah; LFP; built-in BMS; 5000 cycles; 12 kg. The LFP battery is the upgrade replacement for lead-acid; the keys are matching charge voltage, no old/new mixing, and no low-temp charging.
Extra tip: size the rack floor for weight. One LFP is 12 kg; 10 units is 120 kg. Lead-acid at 30 kg each is 300 kg for 10. LFP is much easier on rack and slab loading.