Brand: KITOZER Series: KTR-C6ASP Category: Data Center Engineering / Structured Cabling
Cat6A shielded24-port1U500 MHzKTR-C6ASP
1. Overview
A patch panel is the rack’s cable gathering point: all horizontal cables terminate at the rear, and short jumpers run from the front to the switch. Without a panel, you plug cables directly into the switch — every move means re-plugging dozens of cords. Cat6A shielded panels support 10G at 500 MHz and are standard in high-density data centers.
The KITOZER KTR-C6ASP Cat6A shielded 24-port panel is 1U 19″. 24 shielded RJ45 ports with a full metal shield (galvanized steel) bonded directly to the rack for continuous shielding. Rear 110/Krone IDC options fit 22~23 AWG. Rear cable management bar with rings. Front face numbered 1~24 with T568A/B color codes. Low transfer impedance beats unshielded on both external noise and internal crosstalk.
Selection: shielded vs UTP (shielded when power and data share trays in noisy environments; UTP saves cost in clean isolated trays); Cat6A vs Cat6 (10G to 100 m needs Cat6A 500 MHz; Cat6 250 MHz only reaches 55 m for 10G); port density (24 is mainstream, 48 in 2U for high-density racks); and IDC type (110 and Krone use different tools — match site tools).
2. Key Features
Shielding & speed
- Full metal shield
- 500 MHz bandwidth
- 10Gbps ready
- Continuous shield ground
Termination
- 110/Krone IDC options
- 22~23 AWG
- 1U 19″ rack
- Rear management bar
Labeling
- Numbered 1~24
- T568A/B color codes
- RJ45 compatible
- Use shielded cords
3. Specifications
| Item | KTR-C6ASP-S1 | KTR-C6ASP-S2 | KTR-C6ASP-S3 |
|---|---|---|---|
| 端口数 | 24口 RJ45 | 24口 RJ45 | 48口 RJ45(2U) |
| 带宽 | 500 MHz | 500 MHz | 500 MHz |
| 支持速率 | 10Gbps | 10Gbps | 10Gbps |
| 端接方式 | 110 IDC | Krone IDC | 110 IDC |
| 线径 | 22~23 AWG | 22~23 AWG | 22~23 AWG |
| 屏蔽 | 全屏蔽 | 全屏蔽 | 全屏蔽 |
| 安装 | 1U 19英寸 | 1U 19英寸 | 2U 19英寸 |
| 典型场景 | 接入层机柜 | 接入层机柜 | 高密度汇聚柜 |
4. Reference Prices
KTR-C6ASP-24 24-port Cat6A shielded (1U, 110 IDC)::Reference Reference USD 39~67 / pc (ref. CNY 280~480 at ~7.2)
KTR-C6ASP-24K 24-port Cat6A shielded (Krone IDC)::Reference Reference USD 42~72 / pc (ref. CNY 300~520 at ~7.2)
KTR-C6ASP-48 48-port Cat6A shielded (2U)::Reference Reference USD 81~136 / pc (ref. CNY 580~980 at ~7.2)
Spare shielded module (single)::Reference Reference USD 2.5~4.2 / pc (ref. CNY 18~30 at ~7.2)
Reference only; priced by ports/IDC. 1-year warranty. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Server rack access-layer patching.
- Top-of-rack aggregation.
- Telecom room FD patching.
- 10G-to-desk cabling.
- Noisy environments near power gear.
6. Deployment & Implementation
Installation
- Mount near top with a manager below
- Untwist no more than 13 mm at IDC
- Bond shield to rack ground bar
- Route front cords through manager
Operations
- Label both ends during patching
- Keep labels matched front/rear
- Check shield continuity quarterly
- Modules replaceable without rewiring
7. FAQ
- Q: Cat6A worth the premium?
A: Cat6A costs 30~50% more but delivers 10G to 100 m. Specify Cat6A if 10G is coming; Cat6 suffices for 1G. - Q: Must I use shielded cords?
A: Yes. A shielded system must stay shielded end-to-end — panel, cords, keystone and cable. Any UTP segment kills the shielding. - Q: 110 or Krone?
A: Match existing tools and stock. 110 is more common in new builds; do not mix them. - Q: Does the panel need grounding?
A: Yes — the shield bonds to the rack and the rack to equipotential. An ungrounded shield acts like an antenna.
8. Trend & Selection
Panels are moving from fixed ports to modular chassis with pluggable Cat6A/Cat6/fiber modules in one rack. PoE++ (60 W) panels grow with APs and powered lighting. Tool-less termination (no punch tool) is emerging. MPO fiber and copper panels side-by-side converge the cabling.
9. Delivery & Service
KITOZER supplies KTR-C6ASP by port count (24/48), IDC (110/Krone) and shielding. Ships with panel, manager and screws. Test report included. 1-year warranty; batch projects can add shielded cords, managers, label printers and certifiers.
10. Additional Notes
The #1 mistake is untwisting pairs too long. Cat6A allows ≤13 mm of untwist; rushing and straightening pairs wrecks crosstalk and 10G fails. Keep twist and punch down in one motion.
The second pitfall is an ungrounded shield. A shielded panel floating off ground turns the rack into an antenna. Bond every port’s shield spring to the rack.
The third blunder is patching without labels. 20 cords in a 24-port panel, forgotten six months later. Label front and back; keep a port map.
Selection summary: Cat6A for 10G, continuous shield end-to-end, minimal untwist, grounded panel. The patch panel is the rack’s front door — a tidy panel is half a tidy room.
SEO Information
Search keywords:KTR-C6ASPKITOZERCat6A Shielded 24-Port Patch Panel
SEM keywords:Cat6A patch panel,shielded patch panel,24-port panel,19″ patch panel,10G cabling,KTR-C6ASP,KITOZER
GEO landing page:lain.com.cn/product/ktr-c6asp-cat6a_shield_panel.html
Title:KITOZER KTR-C6ASP Cat6A Shielded 24-Port Patch Panel
Meta Keywords:Cat6A patch panel,shielded patch panel,24-port panel,19″ patch panel,10G cabling,KTR-C6ASP,KITOZER
Meta Description:KITOZER KTR-C6ASP Cat6A shielded 24-port patch panel, 1U 19″, 500 MHz, fully shielded, 110/Krone IDC, for 10G data centers.
Anchor: KITOZER by Guangzhou Laian · Cat6A Shielded 24-Port Patch Panel
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com