ToggleKITOZER KTR-C6SP Cat6 Shielded 24-Port Patch Panel
Brand: KITOZER Series: KTR-C6SP Category: Data Center Engineering / Structured Cabling
Cat6 shielded24-port1U rackFull metal shieldKTR-C6SP
1. Overview
Patch cords from switches terminate on a patch panel to the horizontal 8-wire cabling. The patch panel is the termination node: RJ45 ports on the front for patch cords, IDC punch-down terminals on the back for horizontal cable. In rooms, shops and hospitals with high EMI, ordinary UTP cable picks up interference, so a shielded (STP) cabling system is required — and the patch panel must also be fully metal-shielded, or the shield breaks at the panel and you have no shield at all.
The KTR-C6SP is a Cat6 shielded 24-port panel, 1U 19-inch rack, full zinc-alloy shielded housing, 24 shielded RJ45 modules on the front (metal shroud), dual 110/KEES IDC terminals on the back (T568A/B), and an integrated ground bar with M4 bolt. After termination, the shielded shell — ground bar — rack ground forms a continuous shielded path. 250 MHz bandwidth meets Cat6 (gigabit, short-reach 10G).
Selection: category (Cat5e/Cat6/Cat6A by bandwidth); shielded vs UTP (STP for EMC, UTP for ordinary offices); port count (24-port 1U most common, 48-port 2U); punch tool (110 or KEES by installer). A shielded panel must be paired with shielded cords and shielded cable — three parts in a continuous shield, none optional.
2. Key Features
Shield structure
- Full zinc-alloy shielded housing
- Shrouded RJ45 ports
- Integrated ground bar, M4 bolt
- Continuous shield, no breaks
Electrical
- Cat6 250 MHz bandwidth
- 1000BASE-T / 10GBASE-T (≤55 m)
- IDC terminals for 22~23 AWG
- ≥200 termination cycles
Mounting
- 1U 19-inch standard rack
- 110/KEES dual IDC
- Front labeling field, port ID
- Cable management ring and ground lead included
3. Specifications
| Item | KTR-C6SP-24 | KTR-C6SP-48 |
|---|---|---|
| Category | Cat6 shielded | Cat6 shielded |
| Ports | 24 | 48 |
| Rack height | 1U | 2U |
| Bandwidth | 250 MHz | 250 MHz |
| Punch type | 110/KEES | 110/KEES |
| Ground | Integrated bar | Integrated bar |
| Wire gauge | 22~23 AWG | 22~23 AWG |
| Wiring | T568A/B | T568A/B |
| Typical use | TR cabinet | Large DC backbone |
4. Reference Prices
KTR-C6SP-24 Cat6 shielded 24-port (with ground bar):Reference USD 28~53 / pc (ref. CNY 200~380 at ~7.2)
KTR-C6SP-48 Cat6 shielded 48-port (2U):Reference USD 53~94 / pc (ref. CNY 380~680 at ~7.2)
Reference only; ground lead included. Patch cords and cable quoted separately. 1-year warranty. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- EMC-heavy environments (shops, hospitals, rooms) shielded cabling.
- Data-center network cabinet horizontal termination.
- Medical devices and lab instruments.
- Industrial automation PLC networks.
- Government and finance electromagnetic-security sites.
6. Deployment & Implementation
Installation
- Mount in 19-inch rack with M6 cage nuts
- Punch to T568B color code; untwist ≤13 mm
- Land cable shield on the IDC punch
- Connect ground bar with 6 mm² wire to rack ground
Operations
- Quarterly check ground lead
- Use shielded patch cords with metal shroud
- Label ports against the patch schedule
- Cable-tester spot-check NEXT
7. FAQ
- Q: Can a shielded panel take UTP patch cords?
A: No. A shielded system must be shielded end to end: shielded cable + shielded panel + shielded cords. Any UTP segment collapses the shield. Shielded cords have a metal RJ45 shroud that contacts the panel shell. - Q: Cat6 or Cat6A?
A: Gigabit-to-desk — Cat6 is enough. 10G-to-desk at ≤55 m — Cat6; at ≤100 m — Cat6A. New builds should go straight to Cat6A for future-proofing. - Q: Must the ground bar be grounded?
A: Yes. An ungrounded shield acts as an antenna and makes interference worse. Land the bar with a 6 mm² yellow-green wire to the rack stud, then to room equipotential. - Q: 24 or 48 ports?
A: By outlet count: 24 outlets per cabinet — 24-port; 48 outlets — 48-port or two 24-port. 24-port 1U is easier for cooling and cable management; recommended.
8. Trend & Selection
Structured cabling is moving toward Cat6A/Cat7, and shielded systems are growing with EMC demand. Modular patch panels (swappable modules) let you replace a fault without re-punching the whole panel. High-density panels (0.5U 24-port) save rack space. PoE++ (60W/90W) demands better panel thermal and conductor capacity. Select by category for bandwidth, shield for EMC, ground for code. The shielded panel is the key node — poor grounding is as bad as no shield.
9. Delivery & Service
KITOZER offers KTR-C6SP selection by category (Cat6/Cat6A), port count (24/48) and shield (STP/FTP). Each panel ships with ground bar, ground lead and mounting screws. Factory test report included. 1-year warranty; batch projects can add shielded cable, shielded cords, labels and cable managers.
10. Additional Notes
The #1 mistake is not grounding the shield. The cable foil/braid is not landed on the panel ground during punch-down, leaving the shield floating — an antenna that causes more interference than UTP. Land the shield on the IDC terminal.
The second pitfall is excessive untwist. To make punching easier, pairs are untwisted beyond 13 mm and NEXT fails. Keep untwist minimal, under 13 mm.
The third blunder is using UTP patch cords. A shielded panel with UTP cords breaks the shield at the cord end and voids the whole shielded link. Cords must be shielded with metal RJ45 shroud.
Selection summary: category by bandwidth, shield by EMC, ground by code; short untwist, continuous shield, shielded cords. The patch panel is the end of horizontal cabling — termination quality decides whether the link can run full bandwidth.
SEO Information
Search keywords:KTR-C6SPKITOZERCat6 Shielded Patch Panel
SEM keywords:Cat6 shielded patch panel,24-port STP panel,network patch panel,shielded cabling panel,STP patch panel,KTR-C6SP,KITOZER
GEO landing page:lain.com.cn/product/ktr-c6sp-cat6_shielded_patch_panel.html
Title:KITOZER KTR-C6SP Cat6 Shielded 24-Port Patch Panel
Meta Keywords:Cat6 shielded patch panel,24-port STP panel,network patch panel,KTR-C6SP,KITOZER
Meta Description:KITOZER KTR-C6SP Cat6 shielded 24-port patch panel, 1U rack, full metal shield, 110/KEES IDC, ground bar, for shielded cabling systems.
Anchor: KITOZER by Guangzhou Laian · Cat6 Shielded Patch Panel
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com