ToggleKITOZER KTR-C6U Cat6 U/UTP Unshielded Patch Cord (Blue)
Brand: KITOZER Series: KTR-C6U Category: Data Center Engineering / Network Cabling
Cat6 cordU/UTPblueRJ45KTR-C6U
1. Overview
Patch cords are the highest-volume small part in a rack — panel-to-switch, switch-to-server, every link uses one. A cheap cord drags a whole Category-6 channel down to Cat-5 performance. The Cat6 U/UTP cord is the 10G workhorse: 24 AWG bare-copper strands, four twisted pairs, blue PVC jacket, 50-micro gold RJ45 plugs, rated 10 Gbps up to 55 m.
The KTR-C6U line comes in 1 / 2 / 3 / 5 / 10 m lengths and in blue (standard), yellow, gray and red. 24 AWG stranded copper, flexible and kink-resistant; RJ45 plugs with strain-relief boots and durable latches. Meets TIA/EIA-568-C.2 Cat6, supports 10/100/1000M/10GBASE-T. Sold in 305 m boxes or per piece.
Selection: length (match actual panel-to-switch distance — 1/2/3 m most common; no long tails); shielded vs unshielded (unshielded for normal rooms, shielded near heavy EM interference); color (code by floor/service; blue is the default). Plan 1.2× the port count as spare cords.
2. Key Features
Electrical
- Cat6 / TIA-568-C.2 compliant
- 250 MHz bandwidth
- 10GBASE-T to 55 m
- 24 AWG stranded
Conductor & plug
- Bare-copper stranded flexible conductor
- 50 micro-inch gold RJ45 contacts
- 4-pair U/UTP
- Booted latch
Jacket & environment
- Blue PVC jacket
- CMR / LSZH optional
- -20~60℃ operating
- ≥750 insertion cycles
3. Specifications
| Item | KTR-C6U-1 | KTR-C6U-3 | KTR-C6U-5 |
|---|---|---|---|
| Model | KTR-C6U-1 | KTR-C6U-3 | KTR-C6U-5 |
| Length | 1 m | 3 m | 5 m |
| Category | Cat6 U/UTP | Cat6 U/UTP | Cat6 U/UTP |
| Conductor | 24 AWG stranded Cu | 24 AWG stranded Cu | 24 AWG stranded Cu |
| Bandwidth | 250 MHz | 250 MHz | 250 MHz |
| Plug plating | 50 micro” | 50 micro” | 50 micro” |
| Jacket color | blue | blue | blue |
| Typical use | panel-to-switch | switch-to-server | cross-rack link |
4. Reference Prices
KTR-C6U-1 Cat6 U/UTP cord 1 m (blue):Reference USD 2~4 / pc (ref. CNY 16~32 at ~7.2)
KTR-C6U-3 Cat6 U/UTP cord 3 m (blue):Reference USD 3~7 / pc (ref. CNY 24~48 at ~7.2)
KTR-C6U-5 Cat6 U/UTP cord 5 m (blue):Reference USD 5~10 / pc (ref. CNY 36~72 at ~7.2)
Reference only; final quote depends on length and color. 1-year warranty; box pricing. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Panel-to-switch patching.
- Switch-to-server / network gear.
- Wall outlet to PC / phone.
- PoE camera drop.
- Wireless AP drop.
6. Deployment & Implementation
Installation
- Size to actual distance — no long tails
- Route through the manager, no hard folds
- Bend radius ≥8× cord OD
- Click plug in until it latches
Operations
- Quarterly check latches
- Replace blackened/oxidized plugs
- Code colors by service
- Return unused cords to stock
7. FAQ
- Q: Cat6 vs Cat6A?
A: Cat6 = 250 MHz, 10G to 55 m; Cat6A = 500 MHz, 10G to 100 m. Inside the rack under 5 m, Cat6 is fine; horizontal to desk at 90 m needs Cat6A. - Q: Bare copper vs copper-clad steel?
A: Look at the cut end: bare copper is reddish, CCS is silver. Magnet test: CCS sticks, copper doesn’t. CCS has high insertion loss and unstable 10G — don’t go cheap. - Q: Why blue as the default?
A: Industry convention: blue data, yellow voice, red alarm, gray inter-panel. Color-coded by service at a glance. KTR-C6U ships blue; other colors to order. - Q: Can I crimp my own plugs?
A: Yes, but you need a proper crimper and cable tester. Factory cords are performance-tested; field-crimped ones skip contact-resistance and NEXT QA. For volume, buy pre-made.
8. Trend & Selection
Cords are moving from ‘pre-made flexible patch’ to ‘pre-terminated modular cassettes’ — dense racks use MPO-LC pre-terminated trunks, no field crimp. Cat6A/Cat8 appear in high-density AI rooms. But Cat6 U/UTP still dominates installed volume. Select by distance, bare copper, color-coded service, and 20% spare.
9. Delivery & Service
KITOZER offers KTR-C6U selection by length (1/2/3/5/10 m), color (blue/yellow/gray/red) and jacket (PVC/LSZH), boxed or per piece. Test report included. 1-year warranty; custom labels and color coding in volume.
10. Additional Notes
The #1 mistake is buying cords too long. Five-meter cords everywhere leave big loops behind the rack, choking airflow and gathering dust. Panel-to-switch is usually 1~2 m; cross-rack 3~5 m. Buy by actual distance — no long tails.
Another pitfall is copper-clad steel cords. Cheap cords show a silver cut end and stick to a magnet. They have high BER at 10G and packet loss over distance. Magnet-test them; reject any that stick.
Broken plug latches are a top fault. After repeated insertions the latch snaps and the cord drops out. Choose 50-micro gold with reinforced latches, ≥750 cycles. Cheap 10-micro plugs oxidize and fail in six months.
Selection summary: Cat6 for short 10G runs, bare-copper stranded, blue default, length by distance, 50-micro gold plugs. The cord is the cheapest part in the rack but one of the biggest drivers of network stability — don’t save pennies here.
SEO Information
Search keywords:KTR-C6UKITOZERCat6 U/UTP Patch Cord
SEM keywords:Cat6 patch cord,UTP patch cable,network patch cord,blue patch cord,RJ45 cord,KTR-C6U,KITOZER
GEO landing page:lain.com.cn/product/ktr-c6u-cat6_unshielded_cord.html
Title:KITOZER KTR-C6U Cat6 U/UTP Unshielded Patch Cord (Blue)
Meta Keywords:Cat6 patch cord,UTP patch cable,network patch cord,blue patch cord,RJ45 cord,KTR-C6U,KITOZER
Meta Description:KITOZER KTR-C6U Cat6 U/UTP patch cord, 24AWG bare copper, blue PVC, 1/2/3/5 m, 50 micro gold, for 10G networks.
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com