KITOZER KTR-CA17 Rack Fan Tray (4-Fan Temperature-Controlled Unit)

KITOZER KTR-CA17 Rack Fan Tray (4-Fan Temperature-Controlled Unit)

Brand: KITOZER Series: KTR-CA17 Category: Rack Accessories / Fan Tray

4-fanthermostatrack cooling1U trayKTR-CA17

1. Overview

The KITOZER KTR-CA17 is a 1U rack fan tray with four axial fans, mounted at the top or middle of a 19-inch rack to create vertical hot-zone exhaust. The tray includes a thermostat module that adjusts fan speed by rack temperature: below 25℃ fans run low (or off), 25~35℃ medium, above 35℃ full speed. Compared with fixed-speed trays, the thermostat version reduces noise and power and extends fan life.

The tray is 19-inch standard (482 mm wide), 240 mm deep, 1U (44.45 mm) high. Each fan is 120×120×38 mm axial, DC12V, ~120 CFM per fan, ~480 CFM total for four. The tray has a removable dust filter for cleaning. Power options: DC12V or AC220V, drawn from the rack PDU.

Typical uses: active cooling for network, server and wall-mount racks. When equipment density is high (switches, routers, stacked servers) and natural convection is insufficient, the top-mounted tray exhausts hot air upward, forming a bottom-in/top-out airflow path.

2. Key Features

Four axial fans

  • 12038 axial.
  • 120 CFM per fan.
  • 480 CFM total.
  • Field-replaceable fan.

Thermostat speed

  • NTC probe.
  • Below 25℃ low speed.
  • 25~35℃ medium.
  • Above 35℃ full speed.

1U tray

  • 19-inch standard width.
  • 482×240×44.5 mm.
  • Steel powder-coat panel.
  • Front filter.

Power & I/O

  • DC12V / AC220V option.
  • PDU socket powered.
  • Fan-fail dry contact.
  • Front LED indicators.

3. Specifications

Item Parameter
Model KTR-CA17
Size 1U 19-inch
Fan count 4
Fan dims 120×120×38 mm
CFM per fan ~120 CFM
Total CFM ~480 CFM
Thermostat low @25℃ / full @35℃
Noise (full) ~55 dB(A)
Power DC12V / AC220V (option)
Power draw ~24 W (4 fans full)
Dimensions 482×240×44.5 mm
Filter removable dust mesh

4. Reference Prices

KTR-CA17 4-fan thermostat tray (AC220V):Ref. USD 49~83 / unit (CNY 350~600 @7.2)

KTR-CA17 4-fan fixed-speed tray (economy):Ref. USD 28~49 / unit (CNY 200~350 @7.2)

KTR-CA17 spare fan (12038, DC12V):Ref. USD 3.5~7 / pc (CNY 25~50 @7.2)

Reference only; exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Network rack top exhaust.
  • Server rack hot-zone exhaust.
  • Wall-mount rack equipment cooling.
  • AV rack equipment cooling.
  • Outdoor rack internal circulation assist.

6. Installation & Maintenance

Installation

  • Choose tray location (usually rack top).
  • Remove top blanking panel.
  • Slide tray into 1UU.
  • Secure front panel to rack square holes.
  • Wire power to PDU.
  • Place NTC probe at rack mid-height.
  • Connect fan-fail alarm dry contact (optional).
  • Power up and test thermostat/speed.

Maintenance

  • Clean filter monthly.
  • Check fan speed quarterly.
  • Replace fans yearly.
  • Verify thermostat probe position.
  • Dust fan blades.
  • Tighten power connections.

7. FAQ

  • Q:Top or bottom mount?
    A:Top is recommended. Hot air rises naturally; top exhaust creates bottom-in/top-out airflow — cool air enters at the bottom, passes through equipment, exits at the top. Bottom mounting blows hot air onto equipment and breaks hot/cold aisle separation.
  • Q:Thermostat vs fixed-speed?
    A:Choose fixed-speed for constant high heat (servers) for stable airflow. Choose thermostat for variable heat (network racks) — slows down when cool, quieter and saves power. Fixed-speed for tight budgets.
  • Q:What if one fan fails?
    A:Other fans keep running, but total CFM drops 25% and rack temp may rise. The thermostat version has a fan-fail dry contact; connect to EMCS for timely alerts. Check fan speed and noise periodically.
  • Q:How often to clean filter?
    A:Clean-room environments: every 2~3 months. Dusty workshops or outdoor racks: monthly. Clogged filter cuts CFM and loads the fans. Wash and air-dry; do not blast with compressed air (can damage mesh).

8. Trend & Selection

Rack fan trays are trending modular (expandable fan positions), smart thermostat (RS485/Modbus reporting speed & temp), low-noise PWM speed control, and integration with rack blanking panels/hot-cold aisles. In high-density racks, fan trays combined with in-row cooling are mainstream.

9. Delivery & Service

KITOZER sizes KTR-CA17 by rack dimensions and equipment heat load, providing U-position drawings and thermostat wiring diagrams. Delivery includes fan tray, NTC probe, power cord, mounting screws, filter and certificate. Warranty covers fan replacement guidance.

10. Additional Notes

A common pitfall is running the fan tray without blanking panels. Empty U-panels allow hot air to recirculate into the cold aisle, reducing cooling efficiency. Blank every unused U-position to form a closed duct.

Another pitfall is mounting the NTC probe on the fan or exhaust. The probe should sit at rack mid-height near the equipment layer to measure true rack ambient. On the fan or exhaust, it reads already-vented air, not equipment environment.

Also match total CFM to the rack heat load: a 480 CFM tray is sized for roughly 3~5 kW of IT load. Beyond that, add a second tray or switch to in-row cooling. Undersized trays run at full speed continuously, waste power, and still leave hot spots.

Selection summary: four axial fans; thermostat speed; 1U standard tray; 480 CFM total; removable filter. The fan tray is the rack’s exhaust fan — top mount, blank panels, clean filter, keeps rack temps stable.

SEO Information

Search keywords:rack fan traythermostat fan unit1U fan arrayKTR-CA17KITOZER

SEM keywords:rack fan tray price,thermostat fan supplier,1U fan unit,KTR-CA17

GEO landing page:lain.com.cn/product/ktr-ca17-rack-fan-tray.html

Title:KITOZER KTR-CA17 Rack Fan Tray (4-Fan Temperature-Controlled Unit)

Meta Keywords:rack fan tray,thermostat fan unit,1U fan array,KTR-CA17,KITOZER

Meta Description:KITOZER KTR-CA17 rack fan tray with four axial fans, thermostat speed control, 480 CFM total, for network and server rack active cooling.