KITOZER KTR-CASHF19 19 Inch Cabinet Fixed Shelf (Server Load Rating)

KITOZER KTR-CASHF19 19 Inch Cabinet Fixed Shelf (Server Load Rating)

Brand: KITOZER Series: KTR-CASHF19 Category: Rack Accessories / Fixed Shelf

19 inchfixed shelf80kg loadcold-rolled steelKTR-CASHF19

1. Overview

The KITOZER KTR-CASHF19 is a 19-inch cabinet fixed shelf installed inside standard 19-inch server racks to support non-rackmount devices such as switches, routers, fiber terminal boxes and KVM. The shelf is formed from 1.5 mm cold-rolled steel with electrostatic powder coating, load rating 80 kg, depth options 600, 800 and 1000 mm. The front panel carries U-position labeling and mounting square holes, fixed to rack posts with M6 cage nuts.

KTR-CASHF19 width 19 inches or 482.6 mm, depth 600, 800 or 1000 mm, height 1U or 44.45 mm. Shelf surface has ventilation holes of 7 mm dense array, front edge stop lip to prevent equipment sliding, rear edge cable notch. It includes 4 sets of M6 cage nuts and screws. Color black RAL9005 or light gray.

Typical uses: supporting desktop switches; placing fiber terminal boxes and ODF; mounting KVM monitor and switch; holding UPS battery packs; supporting routers and protocol converters. Fixed shelves suit long-term stationary devices; sliding shelves suit devices needing pull-out maintenance.

2. Key Features

Load structure

  • 1.5 mm cold-rolled steel.
  • Bent stiffeners.
  • 80 kg load rating.
  • Powder-coated rust protection.

Dimensions

  • 19 inch wide or 482.6 mm.
  • 600, 800 or 1000 mm depth.
  • 1U height.
  • M6 cage nuts included.

Ventilation and cable

  • 7 mm vent array.
  • Front stop lip.
  • Rear cable notch.
  • U-position label strip.

Finish

  • Electrostatic powder coat.
  • Black RAL9005.
  • Light gray option.
  • Deburred edges.

3. Specifications

Item Parameter
Model KTR-CASHF19
Standard 19 InchEIA-310
Width 482.6mm(19 Inch)
Depth 600/800/1000mmOptional
Height 1U(44.45mm)
Load rating 80kg(UniformPointLayout)
Steel thickness 1.5mm
Finish Electrostatic Powder Coating
Color BlackRAL9005/Gray-White
Mounting M6Square NutFixed
Vent holes Ø7mmDense Array
Front lip Yes
Accessories M6Square Nut×4+Screw×4
Weight Approx.4.5kg(600mmDeep)

4. Reference Prices

KTR-CASHF19 fixed shelf (600mm deep):Ref. USD 11~18 / pc (CNY 80~130 at 7.2)

KTR-CASHF19 fixed shelf (800mm deep):Ref. USD 14~22 / pc (CNY 100~160 at 7.2)

KTR-CASHF19 fixed shelf (1000mm deep):Ref. USD 17~26 / pc (CNY 120~190 at 7.2)

Sliding shelf pull-out comparison:Ref. USD 28~49 / pc (CNY 200~350 at 7.2)

Reference only; exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Supporting desktop switches.
  • Placing fiber terminal boxes.
  • Mounting KVM switch.
  • Holding UPS battery packs.
  • Supporting routers or converters.

6. Installation & Maintenance

Installation

  • Determine U-position height in rack.
  • Install M6 cage nuts at matching post holes.
  • Align shelf front panel to post holes.
  • Drive M6 screws through front panel into cage nuts.
  • Tighten diagonally with pre-torque then final.
  • Check level with spirit level.
  • Place device center on shelf.
  • Route rear cables through notch.

Maintenance

  • Check shelf screws monthly.
  • Inspect equipment position quarterly.
  • Wipe shelf surface with dry cloth.
  • Touch up scratched powder coat.
  • Check front stop lip for deformation.
  • Log devices and weights on shelf.

7. FAQ

  • Q:Fixed vs sliding shelf?
    A:Fixed shelves are low-cost and rigid, for stationary devices like fiber boxes and converters. Sliding shelves have pull-out rails, for devices needing frequent front or back access like monitors and KVM. Fixed load 80 kg; sliding about 50 kg due to rail limit. Racks mostly use fixed shelves, with a few sliding shelves for KVM.
  • Q:How to choose shelf depth?
    A:Match rack depth and device depth. 600 mm rack uses 600 mm shelf; 800 mm rack uses 800 mm; 1000 mm rack uses 1000 mm. Too shallow means device overhang; too deep wastes space and blocks rear cable routing. Desktop switches about 200 mm deep, 600 mm shelf suffices; servers 700 to 900 mm need matching deep shelf.
  • Q:How is 80 kg load rated?
    A:80 kg is uniformly distributed dynamic load: 80 kg evenly placed on the shelf, permanent deformation below 2 mm. Concentrated point load should be discounted to about 40 kg. UPS battery packs with concentrated weight need point-load evaluation; add two side-by-side shelves if needed. Do not place heavy items at the shelf edge due to cantilever effect.
  • Q:Can I put a desktop PC or monitor on the shelf?
    A:Yes, but watch ventilation and center of gravity. Desktops and monitors have feet; shelf vent holes help airflow. Monitors are heavy 15 to 25 kg, so center on shelf and use front lip to prevent tipping. Large monitors above 27 inches prefer wall or arm mounts to save U-space. Do not let the shelf edge overhang the device too far to avoid cable snag.

8. Trend & Selection

Rack shelves trend toward modular quick-release, ventilation-optimized honeycomb and flow holes, and load-enhanced 2.0 mm steel. Micro-module rooms and high-density racks commonly use load shelves to support non-rack devices, forming a complete accessory system with cable managers, PDUs and fan trays.

9. Delivery & Service

KITOZER sizes KTR-CASHF19 by rack depth and device load, providing shelf layout and U-position planning. Delivery includes shelf, M6 cage-nut screw pack and certificate. Warranty covers shelf layout and load calculation.

10. Additional Notes

A common pitfall is shelf depth mismatch with the rack. The front-to-rear post spacing determines usable depth; an overly deep shelf hits the rear door or blocks PDU routing. Measure the inside distance between front and rear posts before ordering; shelf depth should be 50 mm less. An over-deep shelf can have the front lip cut, but this affects load rating.

Another pitfall is missing M6 cage nuts. All 4 corners of the shelf front panel need cage nuts; installing only 2 top and bottom causes front sag and deformation. Cage nuts must snap into the rack post square holes, not sit in front of them. Use a cage-nut tool from the side until a click confirms seating.

Selection summary: 19 inch, 1.5 mm cold-rolled steel, 80 kg load, depth matched to rack, M6 cage nuts. Fixed shelves are the rack supporting hands; depth-matched, four-corner fixed, level-mounted keep devices stable.