KITOZER KTR-CDC Foldable Containerized Data Center

KITOZER KTR-CDC Foldable Containerized Data Center

Brand: KITOZER Series: KTR-CDC Category: Containerized Systems

13.5m containerQ235B weldedIP5450mm rock woolprecision ACDCIM monitoringfast deploy

KITOZER KTR-CDC containerized data center with open double doors showing racks, precision air conditioner and PDU inside a 13.5m ISO container

1. Overview

The KITOZER KTR-CDC series packs racks, power distribution, cooling, fire suppression and DCIM monitoring into a standard container. Factory prefabricated and crane-lifted on site, it is ready for service. The 13.5 m unit holds multiple rack rows with precision AC, UPS, battery rows and gas suppression, suited to remote sites, mines, wind farms, construction camps and emergency DR.

The body is welded Q235B steel, wall thickness >=1.2 mm, IP54; interior gets a three-coat anti-rust system and 50 mm Class A rock wool insulation with aluminum foil facing for thermal and acoustic comfort.

The foldable variant ships collapsed to one-third volume and unfolds on site, ideal for remote and temporary camps.

2. Key Features

Body and insulation

  • Welded Q235B, IP54; exterior polyurethane topcoat, interior zinc-rich + micaceous iron + polyurethane three-coat system.
  • 50 mm Class A rock wool, >=80 kg/m3, six-face covered.

Power distribution

  • Utility feed enters the distribution cabinet and branches to UPS and battery rows; PDU end-cabinet feeds dual power.
  • Industrial sockets and lighting to code; emergency lighting lasts >=90 minutes.

Cooling and ventilation

  • In-row or rear-door precision AC with hot/cold aisle containment; backup fans handle AC failure.
  • Intake and exhaust louvers are dust- and rain-proof.

Monitoring and fire

  • DCIM host collects temperature, humidity, leak, smoke, access, UPS and AC status with remote alarms.
  • Cabinet HFC-227ea suppression with dual smoke/heat detection.

3. Specifications

Item Configuration A Configuration B
Item Specification
Dimensions 13.5 x 3 x 3 m (foldable ships smaller)
Body Q235B welded, >=1.2 mm wall, IP54
Insulation 50 mm Class A rock wool, >=80 kg/m3
Rack count 12-24 standard racks
Cooling In-row precision AC N+1
Power UPS + battery row, dual PDU
Fire Cabinet HFC-227ea gas suppression
Monitoring DCIM host, remote alarms

4. Reference Prices

KTR-CDC 13.5 m containerized data center (racks, UPS, precision AC, fire, DCIM): reference price USD 90,000~132,000 per unit

KTR-CDC foldable 6 m container (office / IT dual-use, insulated, lit): reference price USD 4,900~7,600 per room

The above prices are reference prices only; the formal quotation prevails. Prices vary by configuration, quantity, site and tax treatment; volume projects can be discussed. Based on exchange rate as of October 2026 (1 USD ≈ 7.2 CNY).

5. Applications

  • Remote mines and wind farms: On-site compute and storage.
  • Construction sites: Rapid deployment, relocatable on completion.
  • Emergency DR: Fast business nodes during incidents.
  • Edge sites: Campus, port and mine edge computing.

6. Installation and Maintenance

Installation

  • Level and harden the pad with drainage slope; connect utility and ground after placement; bond the shell to the grounding grid.

Maintenance

  • Check AC filters and UPS batteries quarterly; inspect seals and drains before wet season; respond to DCIM alarms 24/7.

Sizing tips

  • <=30 kW IT uses a single-container unit; 30-80 kW uses the 13.5 m standard; multiple units cluster into a micro-module pod.

7. FAQ

  • Q: How fast can a container DC deploy?
    A: Factory prefab units are site-ready in 1-2 weeks after placement and power; foldable versions deploy even faster.
  • Q: Does it survive outdoor heat?
    A: 50 mm rock wool plus N+1 precision AC runs from -20 C to 50 C; extremely cold sites add heat tracing.
  • Q: How many racks fit in one unit?
    A: A 13.5 m unit holds 12-24 standard racks, sized for 30-80 kW IT load.
  • Q: Can it expand later?
    A: Multiple units bolt together into a micro-module pod, scaling power and cooling as workload grows.

8. Technology Trends

Edge and AI inference extend to remote sites, mines and wind farms, driving demand for fast, relocatable, low-civil-works container DCs. KTR-CDC integrates power, cooling, fire and monitoring, with foldable variants cutting transport cost. Future units will support liquid cooling and hybrid green-power feeds.

Additional Q&A

  • Q: How is it shipped?
    A: Standard units move by sea and flatbed truck; foldable units triple shipping density when collapsed.
  • Q: What site foundation is needed?
    A: Level, hardened concrete pad sized for the loaded weight, with >=1% drainage slope.
  • Q: Can units be clustered later?
    A: Yes. Multiple units bolt together with bus bridges and fiber end-cabinet links into a micro-module pod.
  • Q: What ambient temperature range?
    A: Designed for -20 C to 50 C; desert sites add extra cooling and sun shades.

Edge and remote compute nodes are driving containerized DC demand for fast, relocatable, low-civil-works deployments. KTR-CDC integrates power, cooling, fire and monitoring; foldable variants cut transport cost. Future units will support liquid cooling and hybrid solar-storage feeds.

KITOZER assembles and burn-in-tests all internal equipment at the factory for 72 hours. On site, after power, ground and network connection, the unit goes live in 1-2 weeks. Three-year warranty and remote DCIM with advance spare shipment.

KITOZER KTR-CDC installed in data center rack with cable management and PDU

SEO Information

Search keywords:containerized data centermodular DCfoldable containeroutdoor roomedge computeKTR-CDCKITOZER

PPC keywords:containerized data center price,modular DC,foldable container room,outdoor integrated cabinet,KITOZER container

GEO landing page:lain.com.cn/en/product/ktr-cdc-container-datacenter.html

Title:KITOZER KTR-CDC Foldable Containerized Data Center

Meta Keywords:containerized data center,modular DC,foldable container,outdoor room,IP54,precision AC,DCIM,KTR-CDC,KITOZER

Meta Description:KITOZER KTR-CDC foldable containerized data center, 13.5 m Q235B body IP54, integrated UPS, precision AC, fire and DCIM for remote wind, mine and edge sites.

Anchor text:KITOZER by Laian · Data center solutions

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER Brand)
Tel / WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Website: lain.com.cn | gdlain.com

Shopping Cart