KITOZER
KITOZER

KITOZER KTR-CT Wire Mesh Cable Tray

KITOZER KTR-CT Wire Mesh Cable Tray

Brand: KITOZER Series: KTR-CT Category: Data Center Engineering

Q235 zinc-plated800x100mm50×100 meshbonding jumperAl cover200kg bracket

1. Overview

The KITOZER KTR-CT U-shaped wire mesh tray is welded from Q235 low-carbon steel and zinc-plated, with 50x100mm mesh and widths from 100mm to 800mm and heights 50-100mm. It is widely used for power and data cabling in data centers, office buildings and industrial parks, offering breathability, heat dissipation and easy inspection.

Compared with enclosed trough trays, mesh trays are lighter and faster to install; cables stay visible, so moves, adds and changes are straightforward. Matching connectors, bonding jumpers, brackets and aluminum covers complete the support system.

A 10-meter standard run uses one connector set and one 6 mm2 copper-braid bonding jumper per meter, with a 200 kg bracket every 1.5 m.

2. Key Features

Material and finish

  • Q235 steel wire welded smooth, zinc plating >=8 um for indoor corrosion protection.
  • Hot-dip galvanized or 304 stainless options suit damp and corrosive sites.

Connector and bonding

  • Connector set includes two plates, bolts, nuts and washers, one per meter; 6 mm2 copper-braid jumper, 300 mm long.
  • The whole tray bonds into an equipotential ground meeting data center earthing rules.

Support and protection

  • Hot-dip brackets, 600 mm reach, >=200 kg load with M10 anchors; threaded rods or angle arms are optional.
  • Snap-on aluminum cover, sized for 800 mm width, adds dust and mechanical protection.

Installation speed

  • Mesh cuts on site; elbows and tees are bent in place, no pre-fabrication needed, saving schedule.
  • Data and power cables sit on separate tiers at code-required spacing.

3. Specifications

Item Configuration A Configuration B
Item Specification
Material Q235 steel, zinc plated
Mesh size 50 x 100 mm
Width range 100-800 mm
Height 50 mm / 100 mm
Connector 1 set per meter, with bolts/nuts
Bonding jumper 6 mm2 copper braid, 300 mm
Bracket spacing 1 every 1.5 m, >=200 kg
Cover (opt.) Snap-on aluminum

4. Reference Prices

KTR-CT-800×100 mesh tray (connectors, bonding, brackets, per 10 m run): reference price USD 10~13 per meter

KTR-CT-800×100 with aluminum cover (dust-protected): reference price USD 13~16 per meter

The above prices are reference prices only; the formal quotation prevails. Prices vary by configuration, quantity, site and tax treatment; volume projects can be discussed. Based on exchange rate as of October 2026 (1 USD ≈ 7.2 CNY).

5. Applications

  • Data centers: Overhead tray above racks, data and PDU power on separate tiers.
  • Office buildings: Ceiling voids for power and data runs to outlets.
  • Industrial plants: Power and control cable routing.
  • Museums and hospitals: Open trays in clean areas for easy inspection.

6. Installation and Maintenance

Installation

  • Anchor brackets into solid slabs; keep straightness within 2 mm/m; bend radius >=6x cable OD.

Maintenance

  • Re-tighten bonds and connectors periodically; replace missing cover clips; re-tie cables after changes.

Sizing tips

  • Data-only runs use 200-300 mm width; mixed power/data tiers use 400-800 mm; outdoor or damp sites choose hot-dip or stainless.

7. FAQ

  • Q: Mesh tray or solid trough?
    A: Data centers and open offices prefer mesh for ventilation and access; damp or corrosive sites use hot-dip or stainless trough.
  • Q: How much load does it carry?
    A: With brackets every 1.5 m, a single tier holds >=200 kg; verify against actual cable weight for multi-tier runs.
  • Q: Does the tray need grounding?
    A: Yes, 6 mm2 copper-bonding jumper every meter ties the tray into the room equipotential ground.
  • Q: Are covers mandatory?
    A: Cleanrooms and dust-rat areas should add aluminum covers; open runs can skip covers to save cost.

8. Technology Trends

Rising cable density favors open mesh trays for airflow and moves, adds and changes. KTR-CT ships as a standard 10 m kit for easy budgeting, and will add intelligent cable identification and organizing accessories.

Additional Q&A

  • Q: How is the tray cut on site?
    A: Use dedicated cutters or angle grind; deburr and touch up with zinc paint after cutting.
  • Q: What if ceiling height is low?
    A: Use flat-rod hangers tight under the slab; choose the 50 mm low-profile tray when clearance is tight.
  • Q: Can data and power share a tray?
    A: Yes, on separate tiers with >=150 mm spacing or a metal divider to avoid EMI.
  • Q: What covers are available?
    A: Standard snap-on aluminum; galvanized steel or stainless covers on request.

As data centers move to modular and micro-module builds, cable routing evolves into separated power/data tiers and hot/cold aisle arrangements. KTR-CT ships as a standardized 10 m kit with connectors and bonding, easy to budget and procure.

KITOZER quantities trays, elbows, tees and brackets from the drawings and ships connectors and bonding in one lot to avoid site delays. Our engineers guide installation to keep runs straight, bonds continuous and tier spacing to code.

SEO Information

Search keywords:wire mesh traycable trayopen traycable basketzinc plated trayKTR-CTKITOZER

PPC keywords:wire mesh tray price,cable basket cost,open cable tray,data center tray,KITOZER tray

GEO landing page:lain.com.cn/en/product/ktr-ct-wire-mesh-tray.html

Title:KITOZER KTR-CT Wire Mesh Cable Tray

Meta Keywords:wire mesh tray,cable tray,open tray,cable basket,zinc plated,Q235,bonding,KTR-CT,KITOZER

Meta Description:KITOZER KTR-CT U-shaped wire mesh tray, Q235 zinc-plated, 100-800mm width, with connectors, bonding, brackets and covers for data centers and buildings.

Anchor text:KITOZER by Laian · Data center solutions

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER Brand)
Tel / WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Website: lain.com.cn | gdlain.com

Shopping Cart