KITOZER KTR-CTR Cable Tray (Ladder & Trough Type) for Datacenter

Brand: KITOZER Series: KTR-CTR Category: Datacenter Engineering 2 / Cable Tray

cable trayladder traytrough traycable trunkingdatacenter cabling

1. Overview

KITOZER KTR-CTR cable tray is the metal support system that routes and protects cables in server rooms. If network cables are the “blood vessels” of a datacenter, the cable tray is the “pipe” — all power cables, network cables and fiber must run through trays, not hang from ceilings or pile under floors. Trays provide: organized routing, mechanical protection, and easy access for maintenance.

KTR-CTR comes in two main types: ladder tray (open rungs, good ventilation, for power cables that generate heat) and trough tray (enclosed channel with cover, dust/rodent/EMI protection, for data cables). Datacenters typically use both: power tray for electrical, data tray for signal, separated by proper spacing.

Materials: cold-rolled steel galvanized (indoor standard), powder-coated (decorative/corrosion-resistant), and stainless steel 304/316 (outdoor or humid environments). Widths from 100mm to 600mm, heights 50~150mm, thickness 1.0~2.0mm. Full accessories: straight sections, elbows, tees, reducers, hangers, supports, splice plates, grounding jumpers — a complete wiring system.

2. Key Features

Ladder tray

  • Side rails + rungs; open ventilation for power cable heat dissipation.
  • Light weight, high load, suited to long-span runs.
  • Rung spacing 200~300mm for cable tie-down.

Trough tray

  • Enclosed channel + cover; dust, rodent and EMI protection.
  • Ideal for data cables (network, fiber, signal).
  • Hinged/removable cover for later additions and service.

Material & finish

  • Galvanized steel: corrosion-resistant, indoor standard, cost-effective.
  • Powder-coated: color options (gray/blue), decorative and anti-corrosion.
  • SS304/316: outdoor, humid or corrosive environments.

System accessories

  • Straights, 90°/45° elbows, tees, crosses, reducers.
  • Hangers (threaded rod + strut), wall/column supports.
  • Splice plates, bolts, grounding jumpers for electrical continuity.

3. Specifications

Item KTR-CTR-100 KTR-CTR-200 KTR-CTR-300
Type Trough Ladder/Trough Ladder
Width 100mm 200mm 300mm
Height 50mm 100mm 100mm
Thickness 1.0mm 1.2mm 1.5mm
Material Galvanized Galv/powder Galv/powder/SS
Load ≤30kg/m ≤60kg/m ≤100kg/m
Span 1.5m 2.0m 2.5m
Length 2m/piece 2m/piece 2m/piece

4. Reference Prices

KTR-CTR-100/200 trough/ladder galvanized tray (100~200mm width, standard fittings): Reference USD 3.5~11 / meter (ref. CNY 25~80 at ~7.2)

KTR-CTR-300/600 heavy-duty powder-coated/SS tray (300~600mm width, SS304): Reference USD 11~49 / meter (ref. CNY 80~350 at ~7.2)

Reference only; final quote depends on width, height, thickness, material (galv/powder/SS) and accessory count. Elbows, tees billed per piece. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Datacenter power and data cable routing.
  • Building weak-current rooms and floor telecom closets.
  • Factory floor power cable runs.
  • Outdoor substations and PV array cable trays.
  • Tunnel and metro long-span cable installation.

6. Installation & Maintenance

Installation

  • Plan routing: power and data trays separated.
  • Set tray elevation: typically 2.4~2.8m below ceiling.
  • Install hangers: anchor threaded rods, spacing 1.5~2.5m.
  • Splice sections: splice plates + bolts, add grounding jumpers.
  • Add supports at elbows/tees to prevent joint sag.
  • Power and data in separate trays, spacing ≥300mm.
  • Close trough covers; tie cables on ladder rungs.

Maintenance

  • Check hanger tightness and tray deformation/sag periodically.
  • Verify grounding jumpers intact for electrical continuity.
  • Ensure trough covers complete to keep dust/rodents out.
  • Open covers or untie rungs when adding cables.
  • Touch up galvanized scratches with anti-rust paint.

7. FAQ

  • Q: Ladder vs trough?
    A: Power cables use ladder (ventilation for heat); data cables use trough (dust/EMI protection). Datacenters need both: power tray + data tray.
  • Q: Galvanized vs stainless?
    A: Dry indoor use galvanized (best value); outdoor or humid (basements, near washrooms) use SS304; coastal high-salt use SS316.
  • Q: How to size tray width?
    A: Cable cross-section ≤40% of tray area (power) or 50% (data). Leave 30%~40% headroom for future expansion.
  • Q: Power-data tray spacing?
    A: Parallel spacing ≥300mm; cross at right angles to minimize interference.

8. Trend & Selection

Datacenter cabling shifts from copper to fiber, increasing data tray share. The trend is modular prefabricated tray systems — factory-made elbows and tees, field assembly, less cutting/welding. Large datacenters use double-deck trays: upper for fiber/network, lower for power. Select by cable count and type; separate power and data; start with galvanized indoors, upgrade to SS for outdoor/humid; order all accessories (elbows, tees, hangers, grounding) per routing drawings; reserve 30%~40% expansion capacity. The tray is the skeleton of cabling — a poor skeleton means messy cable additions later.

9. Delivery & Service

KITOZER provides tray selection and shop drawings: based on cabling diagrams, we calculate tray sizes, routing and accessory BOM. We produce installation detail drawings (elevation, routing, support spacing, power-data separation). Bundled with racks, PDUs, patch panels and cords. Delivery includes tray sections, splice hardware, hangers and supports. Warranty covers replacement parts and installation guidance.

10. Additional Notes

The most common mistake is “buying tray sections but forgetting accessories.” Many BOMs list only meters of tray — elbows, tees, hangers, splice plates and grounding jumpers are all omitted. On site, elbows must be cut and welded, and trays hung with wire ties instead of hangers — neither aesthetic nor code-compliant. The right approach: count from the routing drawing — meters of straight, number of 90° elbows, tees, hanger sets, splice plates — a complete BOM.

Another pitfall: power and data in the same tray. Some projects cut corners, putting power cables and network cables in one tray with a divider. The divider’s isolation is limited — power cable EMI degrades network throughput and causes packet loss. Power and data must run in separate trays with proper spacing — this is code, not optional.

Selection summary: data (network/fiber) in trough galvanized; power in ladder galvanized; width by 40%~50% fill ratio with headroom; indoor galvanized, outdoor/humid SS; order all accessories per drawing; power-data tray spacing ≥300mm. The tray is the cabling skeleton — build it right, and cables stay organized and manageable.

SEO Information

Search keywords:cable trayladder traytrough traycable trunkingdatacenter cablinggalvanized trayKTR-CTRKITOZER

SEM keywords:cable tray price, cable tray manufacturer, ladder tray, trough tray, datacenter cable tray,KTR-CTR,KITOZER

GEO landing page:lain.com.cn/product/ktr-ctr-cable-tray-ladder-trough.html

Title:KITOZER KTR-CTR Cable Tray (Ladder & Trough Type) for Datacenter

Meta Keywords:cable tray,ladder tray,trough tray,cable trunking,datacenter cabling,galvanized cable tray,KTR-CTR,KITOZER

Meta Description:KITOZER KTR-CTR cable tray in ladder and trough types, galvanized/powder-coated/stainless steel, for power and data cables in datacenters, server rooms and building weak-current rooms.

Anchor: KITOZER by Guangzhou Laian · Data center engineering

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart