Table of Contents
ToggleKITOZER KTR-EMC Electromagnetic Compatibility Laboratory
Brand: KITOZER Series: KTR-EMC Category: EMI/RF Shielding > Anechoic Shielded Chamber
>=100 dB shielding10kHz-18GHzanechoic chamberIEC 61000CE/RE/immunity
1. Overview
The KITOZER KTR-EMC laboratory is built as a standard test space composed of five core systems: a shielded chamber, an anechoic chamber, conducted-emission, radiated-emission and immunity test systems, supported by auxiliary instruments, power/earthing, ventilation and monitoring. The shielded chamber uses welded steel plate with shielding effectiveness >=100 dB from 10 kHz to 18 GHz and is delivered with a third-party shielding test report.
The lab covers the IEC 61000 series and equivalent national standards, supporting pre-compliance and pre-certification testing of electronic products for radiated and conducted disturbance and immunity. KITOZER supplies a turnkey service: site survey, design, construction, installation and commissioning acceptance. Building a chamber this way in one coordinated package avoids the common pitfall of buying instruments first and then discovering the room, filters and earthing were never sized to meet the required shielding and quiet-zone performance.
2. Key Features
High-shield enclosure
- Standard chamber 3x4x2.5m, welded >=2mm galvanized steel; motorized single-leaf shielded door with knife-edge contact seals.
- Honeycomb waveguides with cutoff >=10 GHz; power-line filters >=100 dB insertion loss; independent earth <=1 ohm.
Full-frequency test coverage
- 9 kHz-3 GHz EMI receiver with LISN, voltage and current probes for conducted emissions; log-periodic, biconical and horn antennas cover 30 MHz-18 GHz radiated emissions.
- ESD, EFT/burst, surge, dips, conducted and radiated immunity generators meet IEC 61000-4 series.
Anechoic chamber & utilities
- 5x7x4m chamber fully lined with pyramid absorber; 2m turntable to 500 kg and an antenna mast lifting 1-4 m.
- Isolation transformer, 10 kVA UPS, 5 kW precision HVAC and fiber-link radiation-free monitoring keep the environment stable.
Engineering rigor
- Power and signal penetrations all pass through filtered or fiber feedthroughs, so external lab noise does not leak into quiet measurements.
- The shielded door uses a handwheel knife-edge seal that closes evenly, preserving shielding across years of daily open/close cycles.
3. Specifications
| System | Core equipment |
|---|---|
| Shielded chamber | >=2mm welded shell, shielded door, viewport, 4 honeycomb vents, power/signal filters, earth |
| Anechoic chamber | 5x7x4m, 110 sqm pyramid absorber, 35 sqm floor absorber, turntable, antenna mast |
| Conducted emissions | EMI receiver, single/3-phase LISN, voltage/current probes, test table, ground plane |
| Radiated emissions | Log-periodic, biconical, horn antennas, pre-amplifier, low-loss RF cable |
| Immunity | ESD, EFT, surge, dips, conducted/radiated immunity systems |
| Utilities | Oscilloscope, spectrum analyzer, power meter, AC source, isolation transformer, UPS, HVAC, CCTV |
4. Reference Price
KTR-EMC shielded chamber (>=100 dB, incl. door/filter/earth): RMB 800,000-1,500,000 / room
KTR-EMC full EMC lab (chamber + anechoic + full instruments): RMB 3,000,000-6,000,000 / set
Reference prices only; final quotation applies. Based on exchange rate as of October 2026 (1 USD = 7.2 CNY), the chamber is roughly USD 111k-208k and the full lab roughly USD 417k-833k. Final cost varies with frequency range, chamber size, instrument brand and inclusion of turntable/antenna mast.
For labs at the pre-compliance stage, KITOZER can phase the build: deliver the shielded chamber and basic conducted/radiated bench first, then add immunity generators and the anechoic chamber as budget allows. Because the room, filters and earthing are sized once for the full target spec, later instrument additions do not require tearing out the shielded shell.
5. Applications
- Electronics manufacturers: pre-compliance and troubleshooting before shipment.
- Third-party testing houses: accreditation-grade lab construction.
- Universities and research: EMC teaching and research platforms.
- Automotive and appliances: component and product radiated/immunity testing.
6. Installation & Maintenance
Build process
- Survey and design, then welded shell erection, filter/earthing works, absorber lining, instrument siting and tuning.
- A third party measures shielding effectiveness on site and issues the report before handover.
Maintenance
- Clean absorber material and waveguides; inspect shielded-door knife-edge contact and earth bonds.
- Calibrate receiver, antennas and probes on schedule to keep data traceable.
Service notes
KITOZER delivers as a turnkey project with as-built drawings, filter schedules and the shielding test report. We recommend an annual door-seal and earthing check, because a degraded shielded door is the most common cause of a chamber failing re-qualification. Keeping the anechoic absorber dry and undamaged preserves the quiet-zone reflection characteristics that radiated test results depend on.
SEO
Keywords:EMC labelectromagnetic compatibilityshielded chamberanechoic chamberconducted emissionsradiated emissionsimmunity testKTR-EMC
SEM: EMC lab construction, shielded chamber price, anechoic chamber build, EMC test equipment, pre-compliance lab
GEO landing: gdlain.com/product/ktr-emc-lab.html
Title: KITOZER KTR-EMC Electromagnetic Compatibility Lab | Shielded & Anechoic
Meta Keywords: EMC lab, electromagnetic compatibility, shielded chamber, anechoic chamber, conducted emissions, radiated emissions, immunity, IEC 61000, KTR-EMC, KITOZER
Meta Description: KITOZER KTR-EMC lab delivers a >=100 dB shielded chamber (10kHz-18GHz), absorber-lined anechoic chamber, and conducted/radiated emissions plus immunity systems to IEC 61000.
Anchor text: KITOZER EMC labs · shielding solutions
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER)
Tel / WeChat: +86 13922289957 / +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com