ToggleKITOZER KTR-ERV Energy Recovery Ventilator / Fresh Air Unit
Brand: KITOZER Series: KTR-ERV Category: Data Center Engineering / Ventilation
fresh air unitenergy recovery ventilatorheat recoverydouble flowmulti-stage filterEC fanModbus to BMS
1. Overview
The KITOZER KTR-ERV is a fresh air unit with total heat recovery (energy recovery ventilator, ERV) — the core ventilation device for data centers. Data rooms are sealed spaces; racks only dissipate heat rather than consume oxygen, yet a reliable fresh air system is still required to maintain positive pressure, supply ventilation for staff, dilute odors, and enable free cooling with outdoor air in transitional seasons. KTR-ERV draws filtered outdoor air into the room while exhausting stale indoor air; the two streams cross through a total heat recovery core that exchanges both temperature and humidity, recovering cooling (or heating) from the exhaust before outdoor air reaches the AC load.
KTR-ERV is sized by airflow from 500 m³/h up to 2000 m³/h, with large models beyond 3000 m³/h. Each unit comprises a cabinet, a total heat core, supply and exhaust fans, filters, dampers and a controller. The supply fan pushes outdoor air in; the exhaust fan pulls indoor air out; the two fans run independently. The two air streams do not mix inside the core — they only exchange energy. The core uses counter-flow or cross-flow construction with a hydrophilic membrane or paper substrate, recovering both sensible and latent heat, hence “total” heat recovery, as opposed to “sensible” recovery that only exchanges temperature.
Key design parameters are airflow, positive pressure and filtration. Fresh air is sized by occupants (30~50 m³/h per person) or 0.5~1 air change per hour. Supplied air maintains 5~10 Pa positive pressure relative to corridors/outdoors to block dust through door gaps. Filtration is typically G4 + F7 two-stage; regions with high PM2.5 add F9 or activated carbon. KTR-ERV ships with EC centrifugal fans that vary speed by indoor CO₂, differential pressure or BMS commands, and uploads runtime, filter-differential and fan frequency to the environment monitoring system via Modbus-RTU/TCP.
2. Key Features
Total heat recovery
- Hydrophilic core recovers both sensible and latent heat.
- Summer: recovers cooling from exhaust; winter: recovers heat.
- Efficiency 60%~75%, cutting fresh-air AC load.
Independent double flow
- Supply and exhaust fans run independently, airflow adjustable.
- Streams do not mix; only energy is exchanged.
- Maintains room positive pressure, blocks dust.
Multi-stage filtration
- G4 pre-filter + F7 medium filter as standard.
- F9 HEPA section or activated carbon odour section optional.
- Filter differential monitoring with clog alarm.
Smart control
- EC fan variable speed.
- Built-in CO₂ / temp-humidity sensor (optional).
- Modbus-RTU/TCP to BMS.
- Free-cooling mode with 100% outdoor air in transitional seasons.
3. Specifications
| Item | KTR-ERV-500 | KTR-ERV-1000 | KTR-ERV-2000 |
|---|---|---|---|
| Rated airflow | 500 m³/h | 1000 m³/h | 2000 m³/h |
| External ESP | 150 Pa | 200 Pa | 250 Pa |
| Total heat efficiency | 60%~68% | 63%~72% | 65%~75% |
| Fan type | EC centrifugal | EC centrifugal | EC centrifugal |
| Noise | ≤45 dB(A) | ≤50 dB(A) | ≤55 dB(A) |
| Filtration | G4+F7 | G4+F7 | G4+F7 |
| Power | 220V/50Hz | 220V/50Hz | 380V/50Hz |
| Power input | ≤0.4 kW | ≤0.8 kW | ≤1.5 kW |
| Duct size | Φ200 mm | Φ250 mm | Φ315 mm |
| Comm. | Modbus-RTU | Modbus-RTU/TCP | Modbus-RTU/TCP |
| Room area | ≤80 m² | 80~160 m² | 160~300 m² |
4. Reference Prices
KTR-ERV-500/1000 total heat recovery unit (G4+F7, EC fan, controller): Reference USD 1,100~3,500 / unit (ref. CNY 8,000~25,000 at ~7.2)
KTR-ERV-2000/3000 large airflow unit (F9 section, CO₂ sensor, Modbus-TCP): Reference USD 3,500~8,300 / unit (ref. CNY 25,000~60,000 at ~7.2)
Reference only; final quote depends on airflow, filtration grade, core material, duct size and control. Bulk negotiable. Ducts, dampers, insulation and install labor billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Fresh air supply for data rooms and telecom exchanges.
- Ventilation for control centers and command halls.
- Free cooling with outdoor air in transitional seasons.
- Positive-pressure dust control in basement sealed spaces.
- Fresh air pre-treatment for clean rooms and labs.
6. Installation & Maintenance
Installation
- Choose location (exterior wall or above ceiling); leave service space.
- Hang unit; connect fresh and exhaust ducts with insulation.
- Fit weather louver and insect screen on intake; silencer on outlet.
- Wire power and control; connect to BMS.
- Commission airflow and positive pressure; set CO₂ thresholds and schedules.
Maintenance
- Check G4 pre-filter monthly; replace when dirty.
- Replace F7 medium filter quarterly.
- Clean or replace total heat core annually.
- Inspect fan bearings and damper action.
- Cold climates: add freeze-protection damper on fresh air intake.
7. FAQ
- Q: No staff in the room — do we still need fresh air?
A: Yes. The room needs 5~10 Pa positive pressure to block dust, and free cooling in transitional seasons saves energy. - Q: Total vs sensible heat recovery?
A: Total recovers both temperature and humidity; sensible only temperature. Humid south picks total; dry north can use sensible. - Q: How is airflow sized?
A: 30~50 m³/h per person or 0.5~1 ACH, meeting positive pressure; free cooling can go to 100% outdoor air. - Q: Will fresh air be too cold in winter?
A: The core pre-heats fresh air with exhaust heat; extreme cold regions add electric pre-heat or a pre-heating coil.
8. Trend & Selection
As PUE requirements tighten, fresh air moves from optional to standard. Transitional-season free cooling cuts compressor runtime, and total heat recovery lowers annual fresh-air AC load. Size airflow by room area and occupants; choose total vs sensible by local climate; pick filtration by outdoor air quality. EC fans and Modbus are now baseline for unified environment monitoring.
9. Delivery & Service
KITOZER provides sizing, airflow calculation, duct layout and control strategy design. From room area, headcount, local climate and PUE target we produce the fresh-air scheme and BOM. We can coordinate with precision cooling, environment monitoring and fire smoke control. Delivery includes the unit, filters, controller and communication cable. Warranty covers core and filters; we can guide installation and commissioning on site.
10. Additional Notes
Fresh air is the most overlooked and most failure-prone part of a data room. A common mistake is installing only an exhaust fan without supply, creating negative pressure that sucks dust through door gaps and cable penetrations; or leaving the intake without weather louver and filter, letting rain, insects and catkins straight into the room. A fresh air system is not “opening a window” — it is an engineered system of filtration, heat recovery, pressure regulation and BMS integration.
The heat core is consumable: paper cores last 2~3 years, membrane cores a bit longer. If filters are not replaced on time, airflow drops and heat recovery efficiency falls with it — many “installed but useless” ERVs are simply clogged filters. Tie filter-differential alarms into the environment system and replace on threshold, not after airflow is already lost.
Selection: small rooms pick KTR-ERV-500, medium 1000, large 2000/3000; humid south pick total heat core, dry north may pick sensible; filtration G4+F7 or F9 by outdoor PM2.5; EC variable fan with Modbus to BMS. Fresh air must be positive, filtered, heat-recovered and monitorable — all four, or none.