KITOZER KTR-FA-LC4 LC Duplex Fiber Optic Adapter (Ceramic Sleeve, Low IL)

KITOZER KTR-FA-LC4 LC Duplex Fiber Optic Adapter (Ceramic Sleeve, Low IL)

Brand: KITOZER Series: KTR-FA-LC4 Category: Fiber Cabling / Adapter

LC duplexCeramic sleeveIL <=0.2 dBODF/FTTHKTR-FA-LC4

1. Overview

The KITOZER KTR-FA-LC4 is an LC duplex fiber optic adapter (also called coupler or flange) used in fiber distribution frames (ODF), terminal boxes and cabinets to mate two LC patch cords. One patch cord runs from a switch/optical module and plugs into one side; another runs from a wall outlet and plugs into the other. A precision ceramic sleeve inside aligns the two ferrules so light couples from one fiber to the next with low insertion loss and high return loss. Compared with item 863 (48-port LC ODF), the ODF is the enclosure; KTR-FA-LC4 is the mating component installed on its panel—a bare ODF needs 24 or 48 adapters to be usable.

Specs: LC duplex interface (two LC ports in one adapter, TX and RX); ceramic zirconia (ZrO2) sleeve with bore accuracy +/-0.0005 mm; insertion loss <=0.2 dB (typical 0.1 dB); return loss >=50 dB (UPC polish); >=500 mating cycles; single-mode and multi-mode compatible; metal spring clip for panel mounting; plastic LC latch housing. LC is half the size of SC (small square vs large square), allowing higher port density. Unlike ST’s threaded coupling, LC uses a push-pull latch for faster, safer insertion.

Typical uses: data center switch optical-module patching; enterprise fiber-to-the-desk cabling; FTTH splitter boxes; media converter / optical modem patching; surveillance fiber links; industrial fiber rings. A 48-port ODF requires 48 LC duplex adapters (each duplex adapter = two fibers = one TX/RX channel).

2. Key Features

Ceramic sleeve alignment

  • Zirconia (ZrO2) ceramic sleeve.
  • Bore accuracy +/-0.0005 mm.
  • Ferrule offset <0.5 um.
  • Wear-resistant, stable.

Low insertion loss

  • IL <=0.2 dB (typical 0.1 dB).
  • RL >=50 dB (UPC).
  • Supports 10G/25G/100G modules.

LC duplex, high density

  • One adapter = 2 fibers (TX+RX).
  • Half the size of SC.
  • Ideal for high-density ODF.
  • Push-pull latch, fast.

Metal clip mount

  • Spring clip snaps into panel.
  • Easy installation.
  • Resists loosening.
  • Reusable.

3. Specifications

Item Parameter
Model KTR-FA-LC4
Type LC duplex adapter
Interface LC-LC duplex
Sleeve Zirconia ceramic (ZrO2)
Bore accuracy +/-0.0005 mm
Insertion loss <=0.2 dB (typ 0.1 dB)
Return loss >=50 dB (UPC)
Mating cycles >=500
Fiber type SM / MM
Mounting Metal spring clip
Housing Plastic (LC latch)
Rate support 10G/25G/100G

4. Reference Prices

KTR-FA-LC4 LC duplex (ceramic): Ref. USD 0.4~0.8 / pc (CNY 3~6 at 7.2)

KTR-FA-SC2 SC simplex: Ref. USD 0.3~0.7 / pc (CNY 2~5 at 7.2)

KTR-FA-ST ST (metal sleeve): Ref. USD 0.7~1.4 / pc (CNY 5~10 at 7.2)

KTR-FA-LC4-APC LC duplex APC (green): Ref. USD 0.7~1.3 / pc (CNY 5~9 at 7.2)

KTR-FA-SC-LC SC-LC hybrid: Ref. USD 0.6~1.1 / pc (CNY 4~8 at 7.2)

Bare ODF panel (for adapters): Ref. USD 2~4 / panel (CNY 15~30 at 7.2)

Reference only; 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Data center switch optical-module patching.
  • Enterprise fiber-to-the-desk.
  • FTTH splitter box mating.
  • Media converter / optical modem.
  • Surveillance fiber links.
  • Industrial fiber rings.

6. Installation & Maintenance

Installation

  • Push adapter into panel hole from the rear; spring clip snaps in.
  • Audible click confirms seating.
  • Orient latch upward.
  • Clean ferrule end-face with alcohol swab before insertion.
  • Align LC plug and push until latch clicks.
  • To remove, depress the LC latch tail, then pull.
  • Do not twist the plug (wears the ceramic sleeve).
  • Verify continuity with a visual fault locator.
  • Measure IL with OTDR or power meter.

Maintenance

  • Monthly clean sleeve end-face with alcohol swab (dust raises IL).
  • Keep dust caps on unused ports.
  • Always depress latch before pulling (never yank).
  • Quarterly continuity check with VFL.
  • If a port reads >0.5 dB IL, replace the adapter.
  • Do not leave adapter ports uncapped.
  • Do not drop ceramic sleeves (deformation raises IL).

7. FAQ

  • Q:LC vs SC?
    A:LC uses a 1.25 mm ferrule; SC uses 2.5 mm. LC is half the size, so high-density panels (e.g., 1U 48-port ODF) use LC. SC has a thicker, more durable ferrule and is common in older gear and FTTH splitters. Modern data centers use LC; match the patch cord to the adapter.
  • Q:UPC vs APC?
    A:UPC is flat-polished (blue plug), RL >=50 dB, for general comms. APC is 8-degree angled (green plug), RL >=60 dB, for CATV/PON where reflection matters. Never mate UPC with APC—it scratches the end-face and raises IL. APC adapters have angled bores and are not interchangeable with UPC.
  • Q:Is 0.2 dB IL large?
    A:A link with 10 adapters at 0.2 dB each accumulates 2 dB. Typical optical-module link budget is about 10 dB (including fiber loss), so 2 dB is reasonable. But if one adapter jumps to 1 dB, the end-face is dirty or the sleeve is worn—clean it; if still high, replace.
  • Q:Can adapters be reused?
    A:Yes, the spring clip is designed for removal. But repeated removal weakens the clip (after 5 to 6 cycles it may loosen). In practice, adapters stay installed; patch cords are plugged and unplugged at the adapter ends.

8. Trend & Selection

Adapters move from SC/ST to high-density LC (1U panels from 24 SC to 48 LC). Fiber classes upgrade to OM3/OM4/OM5 for 40G/100G. APC grows for PON and CATV. Metal sleeves give way to ceramic for stability. Bulk adapters give way to pre-loaded modular panels to reduce field assembly.

9. Delivery & Service

KITOZER sizes KTR-FA adapters by ODF port count, supplying sleeve specs and IL test reports. Delivery includes adapters, dust caps, manual. Warranty covers end-face cleaning guidance and IL testing support.

10. Additional Notes

A common pitfall is inserting without cleaning. Dust on the ferrule gets pressed into the sleeve, raising IL for that port and abrading the ceramic, affecting every future plug. Wipe one direction with an alcohol swab, wait for evaporation, then insert.

Another pitfall is mixing LC and SC. If switch modules are LC and you bought SC cords, they will not fit. Check device ports first (switch modules are usually LC; FTTH splitters usually SC; old multiplexers may be ST). Both ends of the cord must match devices and adapters.

Selection summary: LC duplex; ceramic sleeve; IL <=0.2 dB; UPC/APC separated; metal clip. The adapter is the socket of the optical link; the keys are clean end-faces, matched interfaces, and dust caps.

Extra tip: on high-density 48-port LC panels, orient adapters with latches up; reversed orientation forces patch cords into excessive bend radius.