ToggleKITOZER KTR-FA-SCAPC SC/APC Simplex Fiber Adapter (Ceramic Sleeve)
Brand: KITOZER Series: KTR-FA-SCAPC Category: Fiber Adapter / SC/APC Simplex
SC/APCsimplexceramic sleeve<=0.2 dBKTR-FA-SCAPC
1. Overview
The KITOZER KTR-FA-SCAPC is an SC/APC simplex fiber adapter (also called a fiber flange or coupler) used to join two SC fiber plugs in a fiber cabling system. It consists of a plastic or metal housing with a precision zirconia ceramic sleeve inside: two SC receptacles on either side, and the ceramic sleeve aligns the two ferrules so the fiber cores meet within 1 micron, letting light pass with low loss. The APC end face is polished at an 8-degree angle; when mated, the angled faces meet and back-reflected light is directed into the cladding rather than back to the source, giving high return loss (>=60 dB). This makes APC the standard for CATV, PON and long-haul links where reflection matters.
The SC connector was developed by NTT: square push-pull latch with a 2.5 mm ferrule. Simplex means one port (one fiber); duplex means two side-by-side ports (transmit and receive). KTR-FA-SCAPC is a simplex APC (green housing is the industry color for APC; blue is UPC). One side takes an SC/APC plug, the other also an SC/APC plug. Note: APC (green) and UPC (blue) must never be mated; the angles differ and mating them damages the ferrules.
KTR-FA-SCAPC has insertion loss <=0.2 dB (each flange costs no more than about 5% of optical power), return loss >=60 dB, and 1000+ mating cycles. Operating temperature is -40 to +75 C, suiting both outside cabinets and indoor ODF racks. Typical uses: output ports of CATV splitters, FTTH drop cable termination, ODF patching in data centers, and outside-cabinet fiber splicing.
2. Key Features
APC angled face
- 8-degree angle polish, green housing.
- Return loss >=60 dB.
- Back-reflection routed into cladding.
- For CATV / PON / long-haul.
Ceramic sleeve
- Zirconia sleeve, bore tolerance +/-0.5 microns.
- Ferrule alignment within 1 micron.
- Insertion loss <=0.2 dB.
- Wear-resistant, 1000+ cycles.
SC latch
- Square body, push-pull plug-in.
- Latch holds firmly.
- High density for ODF rows.
- Simplex or duplex options.
Wide-temp
- -40 to +75 C operating.
- Metal shielded housing option.
- Suits outside cabinets.
- Flame-retardant plastic option.
3. Specifications
| Item | Parameter |
|---|---|
| Model | KTR-FA-SCAPC |
| Type | SC/APC simplex adapter |
| End face | APC (8-degree angle, green) |
| Coupling | SC to SC, simplex |
| Ferrule | 2.5 mm ceramic |
| Sleeve | Zirconia ceramic |
| Insertion loss | <=0.2 dB |
| Return loss | >=60 dB |
| Repeatability | <=0.1 dB over 1000 cycles |
| Interchangeability | <=0.2 dB |
| Mating cycles | >=1000 |
| Operating temp | -40 to +75 C |
| Housing | Plastic or metal-shielded option |
| Fiber | Singlemode (9/125 micron) |
| Dimensions | approx. 60x28x12 mm |
4. Reference Prices
KTR-FA-SCAPC simplex (ceramic sleeve): Ref. USD 0.4~0.8 / pc (CNY 3~6 at 7.2)
KTR-FA-SCUPC SC/UPC simplex (blue): Ref. USD 0.3~0.6 / pc (CNY 2~4 at 7.2)
KTR-FA-SCAPCD SC/APC duplex: Ref. USD 0.8~1.4 / pc (CNY 6~10 at 7.2)
KTR-FA-LCAPC LC/APC duplex: Ref. USD 0.7~1.1 / pc (CNY 5~8 at 7.2)
KTR-FA-FCAPC FC/APC (screw round): Ref. USD 0.6~1.0 / pc (CNY 4~7 at 7.2)
Adapter panel (12 ports): Ref. USD 3.5~5.6 / panel (CNY 25~40 at 7.2)
Reference only; 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- CATV splitter output ports.
- FTTH drop cable termination.
- ODF patching in data centers.
- Outside cabinet fiber joints.
- PON OLT / ONU patching.
- Lab test equipment connections.
6. Installation & Maintenance
Installation
- Press the adapter into the square SC cutout on the ODF panel or fiber box.
- Listen for the click (latch engages).
- Before plugging, wipe the ferrule end with an alcohol swab.
- Align the plug latch up and push in until latched.
- To unplug, pinch the plug tail; never pull the cord.
- Mate green (APC) with green, blue (UPC) with blue; never mix.
- Test continuity with a visual fault locator.
- Measure insertion loss with a light meter; should be <=0.2 dB.
Maintenance
- Quarterly: clean ferrule ends with an alcohol swab (dust increases loss).
- Cap unused ports with dust plugs.
- After 1000 cycles, check sleeve tightness; replace if loose.
- Replace adapters with scored end faces (view under microscope).
- Never touch the ferrule end with fingers (oil contamination).
- Cracked housings must be replaced (dust/water seal fails).
7. FAQ
- Q:Can APC and UPC be mated?
A:No. APC is an 8-degree angle (green); UPC is a slight sphere (blue). Mating them puts an angled face against a flat face, causing poor contact, high loss (often >1 dB), and repeated mating ruins the angle. Keep colors consistent: CATV/PON use green APC; LAN in data centers often uses blue UPC. - Q:Insertion loss is too high?
A:Most often the end face is dirty. Clean the ferrule with a one-click cleaner; this fixes 90% of cases. Next: the sleeve is worn after 1000+ cycles, bore enlarged, ferrules misalign; replace the adapter. Third: cable bend radius too small (<30 mm) leaks light; reorganize routing. Fourth: broken fiber core (bad splice); re-splice. - Q:How much light does one flange cost?
A:KTR-FA-SCAPC is rated <=0.2 dB, about 4.5% power loss per flange. A link with 10 flanges loses 2 dB total (about 37% power), which matters on long-haul. Keep flanges to 5 per link; replace extra patch connections with splices. - Q:Ceramic sleeve vs bronze sleeve?
A:Ceramic (zirconia) is precise (+/-0.5 microns), durable (1000+ cycles) and costs 3 to 6 RMB; good for backbone in the data center. Bronze (nickel-plated) is less precise (+/-2 microns, 500 cycles) and cheaper (1 to 2 RMB), for temporary test setups. KTR-FA-SCAPC ships with ceramic; do not downgrade to bronze to save money.
8. Trend & Selection
Fiber adapters move from SC/LC to MPO (12/24-fiber high-density) for 40G/100G/400G links. End-face finish shifts from UPC to APC, especially in PON and CATV. Sleeves split between high-precision ceramic (backbone) and low-cost plastic (short reach). Adapters go from single ports to modular panels (12/24 ports) integrated in ODFs. In high-density data centers, pre-terminated MPO trunks replace field splicing, reducing adapter count but raising unit price.
9. Delivery & Service
KITOZER sizes KTR-FA-SCAPC by ODF port count and fiber type (singlemode/multimode, APC/UPC), supplying an end-face color chart. Delivery includes adapters, dust caps and certificate. Warranty covers loss-test guidance and end-face cleaning training.
10. Additional Notes
A common pitfall is plugging in without cleaning. Technicians pull a plug out of a bag and insert it directly; hand oil and ambient dust stick to the end face, causing high loss that is hard to clean later. Always clean with a click cleaner or alcohol swab before insertion; this is basic fiber discipline.
Another pitfall is unplugging by pulling the cord. Staff tug the cord instead of the plug; over time the ferrule debonds from the cable and the whole jumper is scrapped. Pinch the plug tail. Post a sign near cabling: “pinch the plug, never pull the cord.”
Selection summary: SC/APC; simplex; ceramic sleeve; <=0.2 dB; >=60 dB return loss. Adapters are tiny passive parts but dominate link loss; the keys are clean end faces, matching green/blue colors, and never pulling the cord.
Additional tip: although adapters are small, they account for most of the link loss. A 10 km fiber link has 0.1 dB per splice but 0.2 dB per patch; 10 patches cost 2 dB, equal to 2 extra km of fiber. Design for splicing and minimize flanges.
SEO Information
Search keywords:SC/APCsimplexceramic sleevegreen
SEM keywords:SC/APC fiber adapter,simplex fiber coupler,ceramic sleeve flange,CATV fiber connector,KTR-FA-SCAPC,KITOZER
GEO landing page:lain.com.cn/product/sc-apc-simplex-fiber-adapter-fascapc.html
Title:KITOZER KTR-FA-SCAPC SC/APC Simplex Fiber Adapter (Ceramic Sleeve)
Meta Keywords:SC/APC fiber adapter,simplex fiber coupler,ceramic sleeve flange,CATV fiber connector,KTR-FA-SCAPC,KITOZER
Meta Description:KITOZER KTR-FA-SCAPC SC/APC simplex fiber adapter, ceramic zirconia sleeve, insertion loss <=0.2 dB, return loss >=60 dB, for fiber patch joints.
Anchor: KITOZER official · fiber cabling accessories