ToggleKITOZER KTR-FAFC09 FC/APC Singlemode Fiber Adapter (Broadcast Grade)
Brand: KITOZER Series: KTR-FAFC09 Category: Fiber Cabling / FC/APC Singlemode Adapter
FC/APCsinglemode 9/125return loss 60dBbroadcast gradeKTR-FAFC09
1. Overview
The KITOZER KTR-FAFC09 is an FC/APC singlemode fiber adapter (flange coupler) for mating FC/APC patch cords to equipment optical ports and ODF patch panels. It uses a 2.0 mm ceramic ferrule and zirconia sleeve with 8-degree APC angle-polish end face, return loss above 60 dB, insertion loss below 0.2 dB, meeting strict return-loss requirements of broadcast, CATV and PON analog optical transmission.
KTR-FAFC09 is singlemode 9/125 micron, APC green end-face mark, nickel-plated metal shell with threaded lock nut. It fits FC optical ports and mounts on ODF panels, fiber terminal boxes and media converters. Operating temperature -40 to 85 degrees C, repeatability over 1000 cycles. Shell about 14 by 50 mm with flange fixing.
Typical uses: broadcast CATV optical node mating; PON OLT and ONU port coupling; media converter interconnection; ODF flange coupling; lab optical test links. APC end faces suit analog signals and DWDM systems; PC end faces suit digital data links, and the two must not be cross-mated.
2. Key Features
FC/APC end face
- 8-degree angle polish.
- Return loss above 60 dB.
- Insertion loss below 0.2 dB.
- Green end-face mark.
Ceramic ferrule
- 2.0 mm ferrule.
- Zirconia sleeve.
- Singlemode 9/125 micron.
- Over 1000 cycles.
Metal shell
- Nickel-plated shell.
- Threaded lock nut.
- Flange fixing.
- About 14 by 50 mm.
Environment
- -40 to 85 C operating.
- Moisture and salt-fog resistant.
- Corrosion resistant.
- Outdoor cabinet rated.
3. Specifications
| Item | Parameter |
|---|---|
| Model | KTR-FAFC09 |
| Connector | FC/APC |
| Mode | Single Mode9/125μm |
| End face polish | APC(8Degree Slope) |
| Insertion loss | ≤0.2dB |
| Return loss | ≥60dB |
| Repeatability | ≤0.1dB(1000Times) |
| Interchangeability | ≤0.2dB |
| Ferrule material | Ceramic2.0mm |
| Sleeve material | Zirconia |
| Housing material | Nickel PlatingMetal |
| Operating temp | -40~85℃ |
| Mating cycles | >1000Times |
| Dimensions | Approx.Ø14×50mm |
4. Reference Prices
KTR-FAFC09 FC/APC SM adapter (metal):Ref. USD 1~2.1 / pc (CNY 8~15 at 7.2)
KTR-FAFC09 plastic shell economy:Ref. USD 0.4~0.8 / pc (CNY 3~6 at 7.2)
KTR-FAFC09 duplex adapter (LC/APC):Ref. USD 1.4~2.5 / pc (CNY 10~18 at 7.2)
Dust caps (100 pcs):Ref. USD 2~4 / pack (CNY 15~30 at 7.2)
Reference only; exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Broadcast CATV nodes.
- PON OLT and ONU coupling.
- Media converter interconnection.
- ODF panel flange.
- Lab optical test links.
6. Installation & Maintenance
Installation
- Insert adapter into ODF flange hole.
- Tighten threaded nut.
- FC/APC green end face inward.
- Insert patch cord until click and screw thread tight.
- APC mates APC only; never APC-PC.
- Cap unused ports.
- Inspect end face with fiber microscope.
- Verify link loss with power meter.
Maintenance
- Check adapter tightness monthly.
- Clean ferrule end faces quarterly with cleaner pen.
- Replace scratched or stained end faces.
- Ensure dust caps in place.
- Record baseline link loss.
- Retest link attenuation annually.
7. FAQ
- Q:APC vs PC end face, difference? Mix?
A:APC is 8-degree angle polish, return loss above 60 dB, green end face, for analog CATV and DWDM. PC is flat polish, return loss above 45 dB, blue or beige UPC, for digital data. APC-PC cross-mating scratches the end face and degrades return loss below 30 dB. Always mate the same type. - Q:FC/APC vs SC/APC adapter?
A:Different form factor: FC is round threaded lock, SC is square latch. Both APC green, similar specs. FC suits ODF panels with secure thread, SC suits high-density racks with quick latch. Broadcast CATV uses FC/APC; data centers use SC/APC or LC/APC. - Q:Is 0.2 dB insertion loss normal?
A:Single adapter insertion loss below 0.2 dB is industry standard. A link through multiple adapters, such as pairs at both ODF ends, stacks loss. Budget 0.3 to 0.5 dB per flange in link design. Measured above 0.5 dB means dirty end face or off-center ferrule, so clean or replace. - Q:Do adapters need periodic replacement?
A:With normal use over 1000 cycles, zirconia sleeves and ceramic ferrules last 5 plus years without replacement. But repeated insertion wears the end face; if insertion loss stays above 0.5 dB after cleaning, the ferrule is worn and should be replaced. Missing dust caps or corroded metal shell also warrant replacement.
8. Trend & Selection
Fiber adapters trend toward high density with LC duplex and MPO/MTP, low loss below 0.1 dB, and widespread APC in CATV and 5G transport. Data-center 40G and 100G links heavily use MPO/MTP pre-terminated trunks; field flange coupling is gradually replaced by factory pre-termination.
9. Delivery & Service
KITOZER sizes KTR-FAFC09 by ODF port count and end-face type APC or PC, providing end-face compatibility charts. Delivery includes adapters, dust caps and certificate. Warranty covers link-loss testing guidance.
10. Additional Notes
A common pitfall is plugging an APC patch cord into a PC adapter. APC end faces are angled and green, while PC are flat and blue; forced mating scratches the angled ceramic ferrule, causing permanent loss increase. Before cabling, confirm both ends match; APC cords only into APC adapters.
Another pitfall is missing dust caps. Adapter end faces exposed to room dust accumulate particles on the ceramic ferrule, increasing loss on insertion and scratching the end face. Cap every unused port; cap cord ends when not in use.
Selection summary: FC/APC, SM 9/125, return loss above 60 dB, insertion loss below 0.2 dB, nickel-plated metal shell. Fiber adapters are the joints of the optical link; matching end faces, clean dust protection and periodic retest keep optical transmission reliable.
Additional tip: for bulk purchases, sample-test 10 pieces per batch for insertion and return loss, recording each unit. Although adapters are cheap (a few to a dozen RMB), a link through dozens of flanges accumulates measurable loss on optical power. Choose metal-shell adapters with ceramic ferrules and zirconia sleeves for longer life and consistency over plastic-shell economy models.