Table of Contents
ToggleKITOZER KTR-FAL21 LC Single-mode Fiber Adapter (Flanged Coupler)
Brand: KITOZER Series: KTR-FAL21 Category: Fiber Cabling / Fiber Adapter
LC single modeceramic sleeve≤0.2 dB ILmetal flangeKTR-FAL21
1. Overview
The KITOZER KTR-FAL21 is an LC-type single-mode fiber adapter (coupler) used to join two LC fiber connectors. It uses a precision ceramic sleeve (zirconia) inside, with a metal flange (zinc alloy, chrome-plated) outside for mounting on ODF trays, fiber patch panels and termination boxes. It fits single-mode G.652D/G.657 links in telecom, data centers and campus cabling.
KTR-FAL21 insertion loss ≤0.2 dB, return loss ≥50 dB (UPC polish), interchangeability ≤0.2 dB. Operating temp -40~75℃, mating cycles ≥500. The front is LC duplex (two LC ports per adapter); it can also be split for simplex use. The flange clips or screws onto 19-inch rack adapter strips for easy installation.
Typical uses: pigtail-to-patchcord coupling inside ODF racks; splice pigtailsLead Out from termination boxes via adapters to patchcords; cross-connections between ODF and switches in data center fiber links.
2. Key Features
Ceramic sleeve
- Zirconia ceramic ferrule.
- Bore φ1.25 mm precision.
- ≥500 mating cycles.
- IL ≤0.2 dB.
Metal flange
- Zinc alloy chrome-plated.
- Clip/screw dual fixing.
- Universal 19-inch adapter strip.
- Anti-oxidation wear.
Single-mode UPC
- G.652D/G.657 compatible.
- Return loss ≥50 dB.
- 9/125 μm single mode.
- APC option (green).
Duplex one-piece
- LC duplex one-piece.
- Simplex splittable.
- High-density patching.
- Dust cap included.
3. Specifications
| Item | Parameter |
|---|---|
| Model | KTR-FAL21 |
| Adapter type | LC-LC duplex (single mode) |
| Sleeve material | Zirconia ceramic |
| Flange material | Zinc alloy chrome-plated |
| Insertion loss | ≤0.2 dB |
| Return loss | ≥50 dB (UPC) |
| Interchangeability | ≤0.2 dB |
| Mating cycles | ≥500 |
| Fiber type | Single mode 9/125 μm (G.652D/G.657) |
| Operating temp | -40~75℃ |
| Mounting | Clip/screw on adapter strip |
| Color | Beige (UPC) / Green (APC) |
4. Reference Prices
KTR-FAL21 LC single-mode duplex adapter (UPC):Ref. USD 1.1~2.1 / pc (CNY 8~15 @7.2)
KTR-FAL21 LC single-mode duplex adapter (APC):Ref. USD 1.4~2.5 / pc (CNY 10~18 @7.2)
KTR-FAL21 simplex version:Ref. USD 0.7~1.4 / pc (CNY 5~10 @7.2)
19-inch blank adapter strip (24-port):Ref. USD 4~8 / strip (CNY 30~60 @7.2)
Reference only; exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- ODF rack fiber coupling.
- Termination box spliceLead Out.
- Data center switch patching.
- Campus fiber backbone cabling.
- FTTH split point.
6. Installation & Maintenance
Installation
- Remove adapter from packaging (keep dust caps).
- Align with adapter strip hole and push clip.
- Or fix flange with M3 screw.
- Confirm duplex orientation (Tx/Rx marker).
- Insert LC patchcord (click sound).
- Label the link.
- Replace dust caps when unused.
Maintenance
- Clean end-face with dedicated fiber cleaner pen.
- Do not wipe ceramic sleeve with alcohol swab.
- Insert/extract straight, gentle.
- Check flange tightness periodically.
- Keep dust caps in place.
- Test link with optical power meter.
7. FAQ
- Q:UPC vs APC?
A:UPC (Ultra Physical Contact) has a slightly convex end-face, return loss ≥50 dB, beige, for general data and telephony. APC (Angled Physical Contact) has an 8° angled end-face, return loss ≥60 dB, green, for CATV, PON and broadcast where reflection is sensitive. UPC and APC must not be mated (end-face damage); colors must be clearly distinguished. - Q:High insertion loss — how to troubleshoot?
A:First clean the connector end-face (cleaning pen). Check for scratches or stains. If still high, the ceramic sleeve may be worn (over 500 cycles) or the adapter/connector mismatch. Use OTDR on the full link to locate which connector is lossy. - Q:Duplex vs simplex — which to choose?
A:Fiber links are usually bidirectional (duplex); one LC duplex adapter corresponds to one duplex patchcord (one Tx, one Rx). For unidirectional transmission or space constraints, choose simplex. High-density data centers prefer one-piece duplex to reduce adapter count and space. - Q:Can adapters be reused?
A:Yes, but recommend not exceeding 500 mating cycles. Repeated plugging wears the ceramic sleeve bore, increasing IL. For frequently patched links (e.g. testing), use higher-quality adapters or replace periodically. Flange-fixed is more robust than clip-type.
8. Trend & Selection
Fiber adapters are trending high-density (MPO/MTP), low IL and multi-core integration. With 400G/800G optical modules, MPO backbone + LC branch architecture becomes mainstream in data centers; LC single-mode adapters remain widely used at the branch end.
9. Delivery & Service
KITOZER sizes KTR-FAL21 by ODF port count and link type, providing adapter configuration list and labeling advice. Delivery includes adapter (with dust caps), flange screws, certificate. Warranty covers IL test report and replacement support.
10. Additional Notes
A common pitfall is mixing UPC and APC. Beige (UPC) and green (APC) look similar; if an APC patchcord is plugged into a UPC adapter, it scratches the UPC end-face, causing permanent high loss. Confirm color and end-face type before installation; separate UPC and APC zones on the ODF panel.
Another pitfall is missing dust caps. Exposed ceramic sleeves attract dust; when patching, dust is pressed into the end-face, causing scratches and high loss. Unused ports must have dust caps — a basic fiber rule often ignored on site.
Selection summary: LC single-mode duplex; ceramic sleeve; IL ≤0.2 dB; metal flange; UPC/APC color-coded. The fiber adapter is the link’s socket — small but determines whole-link loss and reliability. Right model, proper flange, dust control, keeps optical links stable.
Contact Us
KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com