KITOZER rack 12 port LC fiber box

KITOZER KTR-FB12R Fiber Box / Rack 12-Port LC

Brand: KITOZER Series: KTR-FB12R Category: Low-Voltage Systems / Fiber Cabling

fiber box1U rack12-port LC duplexsplice trayODF

1. Overview

Fiber cable enters the room from the building low-voltage riser or outside, but cannot plug straight into a switch. The bare fibers must be spliced to pigtails in a box, then patched through adapters to switch optic ports. That box is the fiber distribution box (ODF/termination box). One end is the cable entry where fibers are spliced to pigtails on a splice tray; the other is a panel of adapters — pigtails on the inside, patch cords on the outside to the switch. Rack-mount boxes sit in standard 19″ racks and are the convergence point of the room’s fiber backbone. A stack of them often fills a rack to manage a whole row’s fiber in and out.

The KITOZER KTR-FB12R is a 1U rackmount 12-port LC duplex box. 1U height, loaded with 12 LC duplex adapters (24 fibers), internal splice tray (~24 fibers) and routing guides. Cable enters from the rear; after splicing, pigtails coil on the tray and jump to the panel adapters. Powder-coated steel, flip/drawer front for splicing. LC small form factor is dense, suiting 40G/100G optics. Single-mode (UPC blue/APC green) or multi-mode adapters available.

In room low-voltage cabling, KTR-FB12R mounts at the top of network racks or in a dedicated fiber cabinet. Backbone cable is spliced in, then LC-LC patch cords run to switch ports. It turns bare cable into an orderly socket panel for patching and maintenance. 12-port (24-fiber) suits mid/small rooms; large rooms stack 24- or 48-port units. Labeling is key — each port maps to a user and a switch port so patching never gets chaotic.

2. Key Features

Ports & capacity

  • Ports: 12×LC duplex (24 fibers).
  • Height: 1U rack.
  • Splice tray: ~24 fibers.
  • Single/multi-mode.

Construction

  • Powder-coated steel, gray-white.
  • Flip/drawer for splicing.
  • Splice tray + routing guides.
  • Rear cable entry with gland.

Optical compatibility

  • LC duplex adapters.
  • Pigtails & patch cords compatible.
  • Bend-radius protection.
  • UPC/APC option.

3. Specifications

Item KTR-FB12R
Ports 12×LC duplex (24 fibers)
Height 1U 19″ rack
Splice capacity ~24 fibers
Adapters LC duplex (SM/MM)
Build Powder-steel, flip/drawer
Cable entry Rear gland
End face UPC blue / APC green

4. Reference Prices

KTR-FB12R 1U rack 12-port LC box (adapters + splice tray): Reference USD 25~58 (ref. CNY 180~420 at ~7.2), by loaded adapters & end face

Reference only; final quote applies. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • Room cable termination & patching.
  • Network rack optic convergence.
  • Switch 40G/100G optics access.
  • Building vertical backbone cross-connect.
  • Data-center ODF panels.

6. Installation & Maintenance

Installation

  • Mount box in a 1U rack slot.
  • Enter cable from rear; clamp armor.
  • Strip; splice to pigtails.
  • Tray splices with slack.
  • Land pigtails on inside adapters.
  • Patch outside to switch ports.
  • Label every port.
  • Keep bend radius ≥ spec.

Maintenance

  • Cap unused ports.
  • No hard bends; leave slack loops.
  • Keep labels clear & updated.
  • Clean contaminated adapters.
  • Periodic OTDR spot checks.

7. FAQ

  • Q: How many fibers in 12 LC ports?
    A: An LC duplex port is 2 fibers (TX/RX); 12 ports = 24 fibers. Single-mode capacity counts fibers.
  • Q: What does “loaded” mean?
    A: The box ships empty or loaded. Loaded means 12 LC adapters and 24-fiber pigtails already installed — splice straight away.
  • Q: UPC or APC?
    A: Data links usually UPC (blue); CATV/PON high-return-loss uses APC (green). Keep the whole link uniform.
  • Q: Splice vs field connector?
    A: Inside a box, splicing (low loss, reliable); field fast connectors suit emergencies with slightly higher loss.

8. Trend & Selection

Data centers move to 400G; small LC dominates for density, while pre-terminated MPO rises in high-density backbones. Rack ODF moves from fixed to drawer/modular for easier splicing. Size ports by backbone fiber count; LC high density; 1U rack; tray slack; uniform UPC/APC; loaded adapters for convenience; label; bend-radius protection.

9. Delivery & Service

KITOZER selects fiber boxes by backbone fiber count, switch optic count and SM/MM needs to size KTR-FB12R. Bundled with LC patch cords, pigtails and splitters. Delivery includes box, adapters, splice tray and manual. Warranty covers splicing and patching guidance.

10. Additional Notes

A common pitfall is sharp-bending pigtails. Too-small bend radius breaks fibers or adds loss; coil pigtails loosely in big loops on the tray, never right-angle.

Another pitfall is no labels. Hundreds of unlabeled patch cords mean a future wrong pull cuts service. Label every inside and outside port — pair labels mapping cable ID to switch port.

Selection summary: 1U 12-port LC duplex (24 fibers); tray slack; LC density; uniform UPC/APC; loaded adapters; rear entry gland; label; bend-radius protection. The fiber box is the cable’s home — bare cable in, orderly panel out, so patching stays sane. Size by backbone fibers and switch optic count, stack 12/24-port units, and leave 20% port spare.

After mounting, closing the front/rear doors must not pinch patch cords.