304 stainlessfluorocarbon coatedClass A rock woolmulti-point lockGB 12955

1. Overview

The KITOZER KTR-FD series builds fire-rated, airtight doors from 304 stainless steel with a grey fluorocarbon finish, meeting the GB 12955 fire-door standard. The range covers a composite door with small airtight wicket, a small airtight door and a stainless swing door. Each leaf is filled with Class A fire rock wool or perlite fire board and sealed with intumescent strips plus EPDM gaskets, combining fire and smoke resistance with airtight dust exclusion.

The frame is welded as one piece and installed mid-of-wall; leaf faces and backs are pressed as a unit with overlap >=10mm and gap <=3mm. Surfaces go through degrease, pickle, phosphate and passivation before fluorocarbon coating, reaching >=60um film thickness and >=1000h salt-fog resistance for damp, corrosive and clean environments. The result is a door that reads as a clean stainless architectural element while meeting the fire-rated and sealing requirements that a standard flush door cannot.

2. Key Features

Dual fire and airtight performance

  • Leaf core is Class A non-combustible rock wool (>=120 kg/m3); composite leaves are 75mm thick and swing doors 50mm.
  • Intumescent strips around the frame and auto-lifting or fixed EPDM bottom seals block smoke and dust.

Multi-point locking

  • The composite main leaf carries a 6-point fire/airtight compression lock, handwheel mechanical lock and three-level combination dial; the wicket has an escape-rated fire lock.
  • 304 stainless hinges rated 150kg and fire door closers shut the leaf automatically.

Weather-resistant finish

  • 304 substrate with grey fluorocarbon coating >=60um, weathering >=10 years.
  • Silicone fire sealant (>=1000C) fills the frame-to-wall joint.

Built to tolerances

  • Frame and leaf are welded and pressed rather than assembled from thin folded sheet, which keeps the seal line straight over years of daily use.
  • Hardware is all 304 stainless, so the door resists corrosion in wash-down cleanrooms and humid plant rooms where ordinary carbon steel hardware would rust.

3. Specifications

Type Rough opening (mm) Leaf thick Core Locking
Composite + wicket 3780×3000 75mm Class A rock wool >=120kg/m3 6-pt compression + handwheel + dial
Small airtight door 840×2000 75mm Class A rock wool Fire airtight lock + escape
Stainless swing door 1000×2100 50mm Perlite board >=300kg/m3 Corridor fire lock + escape
Frame 304 stainless mid-wall, 1.8-2.0mm, grey fluorocarbon

4. Reference Price

KTR-FD stainless swing fire door (304 fluorocarbon, incl. hardware): RMB 1,800-2,800 / sqm

KTR-FD composite door with wicket (multi-point lock + dial): RMB 4,500-7,000 / sqm

Reference prices only; final quotation applies. Based on exchange rate as of October 2026 (1 USD = 7.2 CNY), the swing door is roughly USD 250-390 per sqm and the composite roughly USD 625-970 per sqm. Final cost varies with opening size, hand direction, lock specification and quantity; volume projects receive a discount.

KITOZER can supply matched door sets across a whole facility, keeping the frame finish, hinge layout and escape hardware consistent from the main equipment-entrance composite door down to the small wickets. Because the door is both fire-rated and airtight, a single product satisfies two building-code requirements that would otherwise call for separate fire and cleanroom doors.

5. Applications

  • Data centers and server rooms: fire/smoke separation and airtight dust control.
  • Cleanrooms and shielded rooms: clean corridors and EMI-protected area entrances.
  • Basements and damp spaces: corrosion-resistant fire doors.
  • Industrial and public buildings: fire separation in warehouses, workshops and plant rooms.

6. Installation & Maintenance

Installation

  • Set the frame, fix with M12 expansion bolts, plumb it, and fill the frame-to-wall gap with silicone fire sealant.
  • Hang the leaf, adjust hinge clearance so it opens freely and seals shut, meeting overlap and gap tolerances.

Maintenance

  • Check closers, locks and seals periodically; lubricate moving parts.
  • Touch up any coating damage to keep the fluorocarbon film intact and preserve salt-fog performance.

Service notes

Each batch ships with a quality sheet confirming GB 12955 and GB 50210 compliance, film thickness and salt-fog traceability. We recommend an annual inspection of the closer force, lock engagement and seal compression, because a weak closer or a flattened gasket quietly degrades both fire and airtight ratings. Keeping the frame-to-wall silicone intact prevents smoke and dust bypass around the most common leak path.