KITOZER cabinet base with casters adjustable

KITOZER KTR-FL2 Rack Plinth / Adjustable Caster Rack Floor Stand

Brand: KITOZER Series: KTR-FL2 Category: Data Center Engineering / Rack Plinth

rack plinthadjustable feetcasterscold aisleload stand

1. Overview

Server racks are not placed directly on the floor. Standard practice is to install a rack plinth (stand) on the anti-static floor or structure, then bolt the rack to it. The plinth raises the rack so bottom cables enter from under the raised floor or through the plinth, forming a under-cabinet cable path; it levels the rack via adjustable feet for a straight row; and it distributes weight to avoid local floor deformation. The KITOZER KTR-FL2 is purpose-built for modular cold-aisle racks. Rows of racks sit side by side in a cold aisle, requiring flat, even, gap-free bottoms. KTR-FL2 uses welded steel tubing with adjustable feet (±20mm) and locking swivel casters for precise positioning. Common heights are 100/150/200mm for different under-cabinet cable clearance.

In modular cold-aisle projects, the rack plinth is the “foundation layer”: racks sit on it, plinths bolt together, and cold-aisle floor tiles cap the top. The plinth also seals the bottom — preventing cold-aisle air from leaking through gaps into the hot aisle. KTR-FL2 pairs with KITOZER cold-aisle ceilings, end doors and racks as a complete containment system.

2. Key Features

Construction

  • Frame: welded steel, powder-coated.
  • Posts: square steel, adjustable feet at base.
  • Adjustment: ±20mm, anti-slip pads.
  • Casters: 4 locking swivel, ≥150kg each.

Specs

  • Rack fit: 600×1000 / 600×1100mm.
  • Height: 100/150/200mm.
  • Load: ≥800kg per unit.
  • Color: black / off-white.

Installation

  • Removable casters; feet fixed after positioning.
  • Connecting plates keep rows aligned.
  • Bottom cable opening for under-floor ducts.
  • Matches cold-aisle floor tiles.

3. Specifications

Item KTR-FL2-100 KTR-FL2-150 KTR-FL2-200
Height 100mm 150mm 200mm
Rack depth 1000mm 1000/1100mm 1100mm
Feet adj. ±20mm ±20mm ±20mm
Casters 4 locking 4 locking 4 locking
Load 800kg 1000kg 1200kg
Material Steel coated Steel coated Steel coated
Color Black Off-white Off-white

4. Reference Prices

KTR-FL2-100 (H100mm, feet+casters): Reference USD 39~63 (ref. CNY 280~450 at ~7.2)

KTR-FL2-150 (H150mm, depth 1100 fit): Reference USD 53~83 (ref. CNY 380~600 at ~7.2)

KTR-FL2-200 (H200mm, depth 1100 fit): Reference USD 67~104 (ref. CNY 480~750 at ~7.2)

Reference only; final quote applies. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • Modular cold-aisle row plinths.
  • Raising server and network racks.
  • Precision AC and UPS bottom stands.
  • Raised-floor under-cabinet cable paths.
  • Row leveling and alignment.

6. Installation & Maintenance

Installation

  • Select plinth size by rack W×D×H.
  • Roll plinth into position on casters.
  • Adjust feet until level and row-aligned.
  • Lock casters; remove or lift off casters.
  • Set rack on plinth; bolt down.
  • Join plinths with plates; fit floor tiles.

Notes

  • Load check: full rack weight ≤ plinth rating.
  • All feet must bear; no floating.
  • On raised floors, plinth rests on structure.
  • Align rows with string line.
  • Keep cables off casters.

7. FAQ

  • Q: Can racks sit directly on the floor?
    A: Not recommended. No under-cabinet cable path; cables must route overhead. Rack weight also deforms anti-static tiles. Plinth + under-cabinet routing is standard.
  • Q: Must casters stay?
    A: No. Casters are for positioning only; after rolling into place, level with feet and remove or lift casters. Long-term load rests on feet.
  • Q: How to choose plinth height?
    A: By under-cabinet cable clearance: 100mm for light ELV cabling; 150mm common; 200mm for power busway or thick cables. Coordinate with raised-floor height.
  • Q: Cold-aisle vs ordinary plinth?
    A: Cold-aisle plinths need row-spliced sealing, floor-tile fit and bottom air-leak prevention; ordinary ones only raise and level. KTR-FL2 is designed for cold-aisle sealing.

8. Trend & Selection

Modular cold-aisle and micro-module rooms dominate new data centers; rack plinths evolve from simple stands into integrated containment foundations requiring row alignment, bottom sealing and clear cable routing. Choose plinth depth by rack depth (1000/1100); height by under-cabinet routing and floor height; keep load margin (full load ≤80% rated); align rows with string line; seal between plinths; pair with cold-aisle tiles.

9. Delivery & Service

KITOZER provides plinth selection: based on rack dimensions, height, load and cold-aisle layout, we configure KTR-FL2 (100/150/200mm). Bundled with server racks, cold-aisle ceilings/end doors and floor tiles. Delivery includes frame, adjustable feet, casters and connecting plates. Warranty covers installation guidance and deformation correction.

10. Additional Notes

A common pitfall is setting the rack on before leveling the plinth. Discovering a tilt after the rack is on means lifting it again. Level and align the empty plinth row first — with a spirit level and string line — before hoisting racks.

Another pitfall is wrong load calculation. A full server rack (servers + switches) reaches 600–800kg; a plinth rated 500kg will deform over time. Size by full load with 1.5× margin.

Selection summary: plinth depth by rack depth; height by under-cabinet routing; keep load margin; level before racking; align rows; seal between plinths. The rack plinth is the foundation of the cold aisle — a level foundation makes the row and containment fit tightly.

SEO Information

Search keywords:KTR-FL2KITOZER

SEM keywords:rack plinth,rack stand,adjustable rack base,caster rack floor,rack support plinth,KTR-FL2,KITOZER

GEO landing page:lain.com.cn/product/346-rack-floor-ktr-fl2.html

Title:KITOZER KTR-FL2 Rack Plinth / Adjustable Caster Rack Floor Stand

Meta Keywords:rack plinth,rack stand,adjustable rack base,caster rack floor,rack support plinth,KTR-FL2,KITOZER

Meta Description:KITOZER KTR-FL2 rack plinth with adjustable feet and casters, raises server racks and precision AC units, fits modular cold-aisle row installation, adjustable height, sturdy load capacity.

Anchor: KITOZER by Guangzhou Laian · KITOZER products

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart