KITOZER KTR-FL23 Rack Plinth / Heavy-Duty Base with Shock-Absorbing Casters

Brand: KITOZER Series: KTR-FL23 Category: Data Center Engineering / Rack Plinth

rack plinthheavy-dutyshock casterscold aisleKTR-FL23

1. Overview

KITOZER KTR-FL23 is a heavy-duty steel plinth that sits under a rack, lifting the whole row off the floor. Under the raised floor run cabling, the supply-air plenum and fire piping; setting a rack directly on the tiles crushes the floor and blocks downward airflow. The plinth raises the rack 100~300 mm, freeing bottom cable and air space while spreading the load onto the structural floor. The heavy-duty model carries loaded server racks at over a tonne per cabinet.

Shock-absorbing casters mean each corner has both an adjustable leveling foot and a lockable swivel caster. On install you roll the rack-plus-plinth into position, step on the caster locks, then wind the leveling feet down until the casters are just off the floor. That solves whole-rack positioning while keeping the rack solid long-term without caster rubber creep. The rubber also isolates minor floor-borne vibration.

In modular cold-aisle projects, a row of racks must line up dead straight, so the plinth length, width and row-splice holes must match the cabinet bottom exactly, with joining plates between racks. The plinth is also the bottom air-boundary of the containment and must be sealed to stop short-circuit cooling air. KTR-FL23 is offered in 600/800 mm widths and 1000/1200 mm depths, powder-coated for corrosion – the standard base for modular center rows.

2. Key Features

Heavy load

  • Welded steel frame.
  • Over 1000 kg per cabinet.
  • Load spread to the floor.
  • Checked against slab loading.

Shock casters

  • Adjustable M16 feet.
  • Lockable swivel casters.
  • Casters off-loaded after install.
  • Rubber vibration isolation.

Raised cabling

  • 100~300 mm lift.
  • Unblocks downflow air.
  • Bottom power/data space.
  • Optional bottom seal panels.

Row splicing

  • Holes match cabinet bottom.
  • Joining plates make a row.
  • Cold-aisle bottom plenum.
  • Powder-coated finish.

3. Specifications

Item KTR-FL23-60(600Width) KTR-FL23-80(800Width) KTR-FL23-L(ExtendedCabinet)
SuitableWithCabinet Width(mm) 600 800 600/800Side by Side
SuitableWithCabinet Depth(mm) 1000/1200 1000/1200 1000/1200
LiftHighHeight(mm) 100/200 100/200 200/300
Single Cabinet Load(kg) ≥1000 ≥1200 ≥1500(Full Row)
Support Feet AdjustableM16 AdjustableM16 AdjustableM16
Caster Lockable Universal Shock Absorber Lockable Universal Shock Absorber Lockable Universal Shock Absorber
Surface Treatment Electrostatic Powder Coating Electrostatic Powder Coating Electrostatic Powder Coating
Cabinet Joining Connecting Plate Connecting Plate Full-Row Base

4. Reference Prices

KTR-FL23-60 600 mm rack plinth (200 mm lift, shock casters, 1 t load). Reference USD 97~222 / pc (ref. CNY 700~1,600 at ~7.2)

KTR-FL23-80 800 mm heavy plinth (1.2 t load, adjustable feet). Reference USD 167~389 / pc (ref. CNY 1,200~2,800 at ~7.2)

KTR-FL23-L extended row-splice plinth (row assembly, bottom air seal). Reference USD 333~722 / pc (ref. CNY 2,400~5,200 at ~7.2)

Reference only; by rack width, lift height, load and quantity; rack and bottom panels excluded; row-splice plates quoted separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • [‘Loaded server rack lift and support.’, ‘Modular cold-aisle row base.’, ‘Under-floor cabling and air supply.’, ‘UPS and battery cabinet bases.’, ‘Racks that need repositioning.’]

6. Installation & Maintenance

Installation

  • [‘Size width/depth and holes to the cabinet bottom.’, ‘Bolt plinth to the rack on the floor first.’, ‘Roll the assembly into position; lock casters.’, ‘Wind feet down until casters just float.’, ‘Join adjacent racks with plates into a row.’, ‘Seal bottom gaps to stop air short-circuit.’]

Maintenance

  • [‘Check feet carry load evenly.’, ‘Casters lock firmly; rubber not cracked.’, ‘Touch up chips to prevent rust.’, ‘Re-check slab loading when load grows.’, ‘Keep bottom seal panels intact.’]

7. FAQ

  • Q: How high should the plinth lift?
    A: Usually 200 mm, enough for cabling and airflow; set by the under-floor plenum for downflow designs – too high raises the center of gravity.
  • Q: Will casters sag over time?
    A: Correct use: after positioning, level the feet so casters float; casters are only for moving. If they carry load long-term, the rubber creeps.
  • Q: Can a rack sit directly on raised floor tiles?
    A: No. Raised tiles are not rated for loaded racks and will collapse. Heavy racks must sit on a plinth that transfers load to the structure.
  • Q: Must the plinth match the cold aisle?
    A: Yes. The row base must be continuous and sealed, or cold air short-circuits under the row and containment efficiency drops.

8. Trend & Selection

[‘Modular cold aisles demand consistent row bases and bottom sealing; prefabricated, modular bases shipped with the racks are the trend. Choose by rack width/depth, load with margin, and pick the spliced row type for containment; balance lift between cabling and a low center of gravity.’]

9. Delivery & Service

[‘KITOZER supplies rack plinths in volume, configured by row dimensions and lift height. Delivery includes frame, leveling feet, locking casters, row-splice plates and manual. Warranty covers weld distortion and caster aging; we re-check load rating and hole alignment.’]

10. Additional Notes

[‘The common pitfall is leaving the casters loaded. Crews skip the feet and let the rack rest on four rubber wheels; within half a year the rubber creeps, tilting the rack and misaligning row gaps. Always set the feet solid and float the casters after positioning.’]

[‘Another trap is mismatched hole patterns. Cabinet bottom hole spacing varies by maker; building a plinth to maker A while buying maker B racks means on-site drilling and reaming. Always confirm the cabinet bottom drilling drawing before ordering.’]

Selection summary: size by rack width/depth; keep load margin; 200 mm lift balances cabling and airflow; set feet and float casters after install; splice rows with plates; seal the bottom. The plinth is the racks shoes – well-fitted, firm shoes keep the row straight and stop air leakage.