KITOZER KTR-FTB-12 Wall-mount Fiber Termination Box (12-core, SC/FC)

KITOZER KTR-FTB-12 Wall-mount Fiber Termination Box (12-core, SC/FC)

Brand: KITOZER Series: KTR-FTB-12 Category: Fiber Distribution / Termination Box

Wall-mount12-coreSC/FCCold steelKTR-FTB-12

1. Overview

The KITOZER KTR-FTB-12 is a wall-mount fiber termination box installed on walls in entrance rooms, floor boxes and equipment rooms. It terminates the incoming outdoor cable: the cable is stripped, fusion-spliced and pigtail-terminated into SC/FC ports, then patch cords run to switch optical ports. The armored cable cannot bend straight into a switch; a box is needed for splice protection and port conversion. KTR-FTB-12 is that box: cold-steel housing, two internal splice trays, twelve SC adapters on the front, cable glands on the bottom and pigtail exits on the side.

Key specs: 12-core capacity, 12 SC adapters (FC optional); two splice trays (6 cores each); two PG16 glands on the bottom for cable entry; four side ports for pigtails; 1.0 mm cold steel, black powder coat; 300x250x80 mm; wall-mount with four expansion bolts; IP40 indoor; M4 grounding screw; about 2.5 kg.

Typical use: a 6-floor office building puts one KTR-FTB-12 in each floor riser. The 48-core backbone splits 12 cores per floor into the box, and twelve SC patch cords run to the floor access-switch optical ports. At RMB 85~130 each, the wall box is cheaper than a rack ODF and suits distributed floor points.

2. Key Features

12-core termination + splice in one

  • 12 SC adapters on the front.
  • Two internal splice trays.
  • Cable splice and pigtail termination in one box.
  • No separate splice protector needed.

Cold-steel powder coat

  • 1.0 mm steel, impact-resistant.
  • Black coat matches racks.
  • Dust- and bug-proof (IP40).
  • Lockable door.

PG16 glands

  • Two PG16 glands on the bottom.
  • Clamp the armor against pull-out.
  • Dust/water resistant for risers.
  • Accepts multiple small cables.

Wall-mount

  • Four expansion bolts to the wall.
  • Small footprint (300×250 mm).
  • Side exits, no door obstruction.
  • Grounding screw to the riser ground bar.

3. Specifications

Item Value
Model KTR-FTB-12
Type Wall-mount fiber termination box
Capacity 12 cores (12 SC adapters)
Adapter type SC/FC option (SC standard)
Splice tray 2 layers x 6 cores
Cable inlet 2 x PG16 glands on bottom
Pigtail outlet 4 side ports
Material 1.0 mm cold steel
Finish Black powder coat
Dimensions 300x250x80 mm
Mounting Wall (4 expansion bolts)
Operating temp -20 to +70 C
Ingress IP40 indoor
Ground M4 grounding screw

4. Reference Price

KTR-FTB-12 12-core wall box (with adapters): RMB 85~130 / unit (about USD 12~18)

KTR-FTB-24 24-core: RMB 130~180 / unit (about USD 18~25)

KTR-FTB-48 48-core rack-mount: RMB 220~320 / unit (about USD 31~44)

SC adapter (spare): RMB 5~8 / pc (about USD 0.7~1.1)

Splice tray (spare): RMB 15~25 / layer (about USD 2~3.5)

SC single-mode pigtail (1.5 m): RMB 8~15 / pc (about USD 1~2)

Reference prices only; final price subject to quotation. (1 USD ≈ 7.2 CNY)

5. Applications

  • Floor riser termination in office buildings.
  • Factory cable cross-connects and workshop nodes.
  • Yard surveillance fiber-media-converter termination.
  • Residential broadband ONU front-end.
  • Vertical backbone splitting in schools and hospitals.
  • First indoor node after outdoor cable entry.
  • Cell-site RRU remote-fiber termination.

6. Installation & Maintenance

Installation

  • Mark four expansion-bolt holes on the wall, drill and insert sleeves.
  • Hang KTR-FTB-12 and tighten bolts.
  • Feed the cable through the bottom PG16 gland, leave 1 m slack.
  • Strip 3 m of cable; clamp the armor in the gland lug.
  • Splice fibers to pigtails with heat-shrink protectors, place in trays.
  • Coil fibers in the tray, bend radius >=30 mm.
  • Plug SC pigtails into the front adapters.
  • Bond the box ground to the riser ground bar.
  • Close and lock the door; label the cable ID.

Maintenance

  • Check the door seals monthly.
  • Clean SC end faces quarterly with a one-click cleaner.
  • Re-test link loss 3 months after splicing.
  • Do not coil excessive pigtail length inside (excess bend adds loss).
  • Retighten loose PG16 glands.
  • Do not run power cables inside the box; keep them separate.
  • Replace fallen labels.
  • When swapping adapters, unplug pigtails first; do not force the adapter.

7. FAQ

  • Q:What is the difference between a terminal box and an ODF?
    A:An ODF is rack-mounted in a 19-inch cabinet, high capacity (48~144 cores), for central cross-connect rooms. A terminal box is wall-mounted, low capacity (12~24 cores), for distributed floor points. One box per floor; the core room holds the ODF; both link via the backbone.
  • Q:How should spliced fibers be coiled inside?
    A:The splice tray is spiral; fibers wind around it, bend radius no less than 30 mm. Do not make sharp right angles or press hard. Close the tray lid and snap it into the box. One tray holds 6 cores; use two trays for more.
  • Q:How many patch cords fit in the box?
    A:The front has 12 SC ports; one cord per port, max 12. Cords exit through the side ports, not through the door (which can pinch fibers).
  • Q:Can an outdoor cable enter this box directly?
    A:Yes, but install an insulating section before the box: the outdoor cable armor grounds out and then disconnects from the indoor fiber, to prevent ground-potential back-flash. The PG16 clamps the armor, but the armor ground must go to the outdoor electrode, not share the indoor ground.

8. Industry Trends & Selection

Fiber distribution is moving from fixed to modular and high-density. Wall boxes are upgrading from 12-core to 24/48-core with MPO ports. Splice trays stack in layers to reach 96 cores per box. Intelligent distribution (electronic labels, auto port discovery) is entering terminal boxes. IP65 waterproof boxes are used on outdoor poles. Select box capacity by cable core count (with 30% headroom), adapters by SC/FC/LC, and form factor by wall vs rack.

9. Delivery & Service

KITOZER sizes KTR-FTB boxes by floor cable count and interface type, and provides splice-tray layouts and grounding plans. Delivery includes box, SC adapters, splice trays, PG16 glands and manual. Splice guidance and link-test support are covered under warranty.

10. Notes

A common pitfall is not grounding the cable armor. If the outdoor armor is ungrounded, a lightning strike leaves high voltage on the armor, which conducts through the metal strength member to indoor gear. After the PG16 clamps the armor, bond a wire to the outdoor electrode.

Another pitfall is over-coiling. Crews bundle 12 pigtails into a tight ball with bend radius under 30 mm, spiking insertion loss. Coil loosely and smoothly with adequate bend radius; do not chase compactness.

Selection summary: wall-mount; 12-core; SC; cold steel; IP40. The terminal box is the cable’s home; keys are armored grounding, enough splice trays, and gentle bends.

Tip: on delivery, check that splice trays rotate freely; cheap boxes have fixed trays that will not close once fibers are placed. KTR-FTB-12 trays are removable, so layers can be added on site.