48 LC duplex19″ 1ULoaded adaptersSM/MMKTR-LC48B
1. Overview
A fiber patch panel (ODF – Optical Distribution Frame) terminates backbone cable and organizes fiber patching in the rack. The backbone cable from the riser enters the rack, is fusion-spliced to pigtails inside the ODF, and pigtails pass through adapters on the front. Equipment-side LC duplex cords plug into the adapters and run to switch optical ports. A 42U network rack typically carries 2-4 x 1U panels (each 48 fibers = 96 fibers/unit; two panels = 192 fibers for ~20 x 10G switches). The panel does three jobs: (1) protects fragile splices inside the enclosed tray; (2) enables flexible patching (any switch can use any fiber via a cord); (3) provides labeled port management (each port maps to a backbone fiber in the asset log). Common panel pitfalls: buying an empty shell (then buying adapters separately and mismatching); insufficient splice tray room (48 fibers do not fit, bend radius <30 mm, loss spikes); panel/adapter mismatch (LC panel with SC cords).
KITOZER KTR-LC48B is a 48-port LC loaded patch panel. Standard 19″ 1U (482x44x100 mm deep), cold-rolled steel phosphate-coated black; front panel carries 24 LC duplex adapters (48 fibers total, UPC blue or APC green); rear splice tray holds 48 splice sleeves (60 mm heat-shrink per fiber); flip-open tray for splice access; cable entry at the bottom rear (leave 3 m slack coiled in the tray); ships with 24 x 1.5 m LC duplex pigtails (singlemode 9/125 um, UPC blue). Models: KTR-LC48B-SM loaded UPC singlemode; KTR-LC48B-APC loaded APC (green); KTR-LC48B-OM4 loaded OM4 (aqua adapters, for 10G multimode); KTR-LC48B-EMPTY empty panel (self-fit adapters, for mixed configurations).
Selection: fiber mode (data center backbone = singlemode 9/125 um, pick SM; 10G-to-desk OM3/OM4 pick multimode – do not mix); end face (UPC blue for data; APC green for video PON); loaded vs empty (new projects choose loaded – ready to use; retrofits can buy empty and reuse adapters); capacity (48 ports = 48 fibers – size by switch optical ports: a 48-port 10G switch uses one 48-fiber panel; two switches use two); position (mount panels at rack top 1-2U, leave 1 U cord management below; do not mount at the bottom – cords run too far to the switches). After splicing, bend radius >=30 mm (smaller adds >0.5 dB macrobend loss); mechanically anchor the cable strength member (do not let splices carry tension); label every port (port number maps to cable fiber number in the log).
2. Key Features
Construction
- 19″ 1U standard
- Steel powder coat
- Flip-open splice tray
- 48-fiber capacity
Optics
- 24 LC duplex adapters
- 48 fibers loaded
- 24 LC pigtails incl.
- UPC/APC options
Compatibility
- SM 9/125 um
- OM3/OM4 options
- YD/T 778
- 19″ rack 1U
3. Specifications
| Item | LC48B-SM | LC48B-APC | LC48B-OM4 | LC48B-EMPTY |
|---|---|---|---|---|
| Fiber mode | SM 9/125 | SM 9/125 | OM4 MM | n/a |
| End face | UPC blue | APC green | UPC aqua | None |
| Adapters | 24 LC duplex | 24 LC duplex | 24 LC duplex | None |
| Pigtails | 24 LC UPC | 24 LC APC | 24 LC OM4 | None |
| Height | 1U | 1U | 1U | 1U |
| Splice tray | 48 fibers | 48 fibers | 48 fibers | 48 fibers |
4. Reference Prices
KTR-LC48B-SM UPC loaded: Reference USD 83-125 / pc (ref. CNY 600-900)
KTR-LC48B-APC green loaded: Reference USD 111-167 / pc (ref. CNY 800-1200)
KTR-LC48B-OM4 aqua loaded: Reference USD 125-194 / pc (ref. CNY 900-1400)
KTR-LC48B-EMPTY shell: Reference USD 35-56 / pc (ref. CNY 250-400)
KTR-LC-CABLE LC duplex cord (3 m): Reference USD 2-4 / pc (ref. CNY 15-30)
Reference only. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- 10G switch optical termination
- Backbone cable splicing
- Rack fiber patching
- Data center structured cabling
- Telecom closet ODF
6. Deployment & Installation
Install
- Top 1U of rack
- R-ear screws
- Cable bottom entry
- Strength member clamp
Splice
- Splice all 48
- Heat-shrink protect
- Bend radius >=30 mm
- Leave 3 m slack
Label
- Label each port
- Map to cable fiber
- Log in Excel
- Color-code cords
7. FAQ
- Q: How many patch cords for a 48-port panel?
A: 48 ports = 48 fibers = 24 LC duplex ports; each port carries a Tx/Rx pair. A 48-port 10G switch needs 48 LC duplex cords (~3 m each, from panel to switch optical port). Spare 1.2x (54-60 cords). Length: panel at rack top, switch mid-rack -> 3 m; panel and switch adjacent in same U -> 1.5 m. - Q: OTDR shows high loss after splicing?
A: 90% is a tight bend in the tray. If fibers are packed with a bend radius under 20 mm, macrobend loss exceeds 0.5 dB. Open the tray, re-coil fibers in loose large loops (radius >=30 mm), arrange heat-shrink sleeves neatly, do not force the lid closed. Re-test – loss should drop below 0.1 dB. Also re-splice any splice point that reads over 0.1 dB. - Q: Can I plug a multimode cord into a singlemode panel?
A: Physically it fits (same LC interface), but the link fails: singlemode core is 9 um, multimode is 50/125 um, mode-field mismatch adds 3-5 dB and 10G drops. Color-code: blue = SM UPC, green = SM APC, aqua = OM4, beige = OM3. Never mix on one panel; cord color matches adapter color. - Q: Is 48 ports in 1U too crowded?
A: Standard 1U (44 mm) holds 24 LC duplex adapters ~10 mm each = 240 mm on a 482 mm panel, leaving ~120 mm on each side. The rear tray must be organized, not stuffed. If crowded, choose a 2U version (wider tray), but 1U is mainstream when rack U space is tight.
8. Trend & Selection
Fiber panels are moving toward high density and modularity. Trends: MPO/MTP high-density panels (1U holds 144 fibers; one MPO = 12 fibers replacing 12 LC ports, for 40G/100G backbone); sliding trays (front pulls out for access without removing the panel); integrated cable managers (built-in guides keep cords tidy); pre-terminated trunk cables (factory-terminated MPO, plug-and-play on site, no field splicing, cuts schedule by 70%). Traditional 1U 48-port LC panels remain mainstream in small-to-mid rooms – cost-effective and easy to service. Select by: loaded kit (adapters + pigtails, no self-sourcing), SM UPC blue, tray fits 48 fibers, bend radius >=30 mm, label and log every port.
9. Delivery & Service
KITOZER KTR-LC48B ships by SM/APC/OM4/empty, each with panel, adapters (loaded), pigtails (loaded), splice tray, screws, manual and certificate. 1-year warranty; bulk projects can bundle LC duplex cords, MPO trunk cables and fusion splicing services.
10. Additional Notes
Confirm fiber mode (SM/OM4), end face (UPC/APC) and port count (by switch optical ports). For batch orders, splice 48 fibers on one panel first, OTDR-test each; all <=0.3 dB before rolling out.
Common mistake: buying empty shells and self-sourcing adapters. To save cost, installers mix adapters from different vendors; ceramic sleeve tolerances mismatch and loss reads over 0.5 dB on the whole panel. Loaded panels ship with adapters pre-installed and pre-tested – use them.
Second pitfall: over-packed splice tray. To close the lid, installers jam 48 fibers in with a bend radius under 15 mm, adding macrobend loss. The tray has room – coil fibers in loose loops; if the lid will not close, the coiling is wrong, do not force it.
Third blunder: no labels. Forty-eight fibers plugged without labels – three months later nobody knows which port is which, and re-patching causes chaos. Label at splice time: front panel “ODF1-01..ODF1-48”, mapping to “Cable 2#-fiber1..fiber48”; log in Excel (position – fiber – use).
Selection summary: loaded kit (adapters + pigtails), SM UPC blue, 1U 48-port, bend radius >=30 mm, port labels and log, OTDR per fiber.
SEO Information
Search keywords:KTR-LC48BKITOZER
SEM keywords:48 port fiber patch panel,LC loaded ODF,rack mount fiber patch panel,48 core LC patch panel,fiber termination box,KTR-LC48B,KITOZER
GEO landing page:lain.com.cn/product/ktr-lc48b-48port-lc-patch-panel.html
Title:KITOZER KTR-LC48B 48-Port LC Loaded Fiber Patch Panel
Meta Keywords:48 port fiber patch panel,LC loaded ODF,rack mount fiber patch panel,48 core LC patch panel,fiber termination box,KTR-LC48B,KITOZER
Meta Description:KITOZER KTR-LC48B 48-port LC loaded fiber patch panel, 24 LC duplex adapters, 19-inch 1U, for 10G backbone.
Anchor: KITOZER by Guangzhou Laian · KITOZER products
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com