ToggleKITOZER KTR-LC48D Fiber Patch Panel / 48-port LC Duplex OM4
Brand: KITOZER Series: KTR-LC48D Category: Data Center Engineering / Fiber Cabling
48-port LC duplexOM4 multimode1U high densityModular adaptersSplice trayCable manager
1. Overview
The fiber patch panel is the termination hub for the fiber backbone in telecom rooms and racks. Incoming cable is terminated here, mated to switches through adapters and patch cords, and every link is managed, labeled and patched in one place. A good panel is dense, manageable, adapter-replaceable, and includes a splice tray for pigtails. The 48-port LC duplex OM4 panel is the workhorse for high-density 10G/40G multimode cabling.
The KITOZER KTR-LC48D is a 48-port LC duplex OM4 fiber patch panel. The 1U unit carries 48 LC duplex ports (96 fibers) on modular adapter plates that can be swapped for LC/SC/MPO. A built-in splice tray lets the cable enter from the rear, where pigtails are fusion-spliced and coiled with slack. OM4 multimode uses aqua adapters and supports 10G and 40G short-reach links. The cold-rolled steel chassis is powder-coated with cable-routing rings and strain relief so cords bend naturally at the sides, avoiding right-angle macro-bend loss.
Selection confirms density (48 LC duplex = 96 fibers), fiber mode (OM4 multimode), adapter form (LC duplex modular), and whether a splice tray and manager are needed. Large rooms group by cabinet, with 1 to 2 panels per network cabinet linked to the main telecom-room panel by backbone cable. OM4 and OM3 can mate, but keep one mode on high-speed links; the incoming cable fiber count should meet or exceed panel ports, with spare fibers.
2. Key Features
48-port LC duplex density
- 48 LC duplex ports on 1U (96 fibers).
- Modular adapter plates swappable.
- OM4 aqua, 10G/40G.
- Dense, saves U-space.
Splice and routing
- Built-in splice tray for pigtails.
- Rear cable entry and anchoring.
- Side routing rings, natural bend.
- Strain relief prevents macro-bend loss.
Structure
- Cold-rolled steel, powder coated.
- 19-inch rack mount.
- Label bar for port numbering.
- Neat patch-cord management.
3. Specifications
| Item | Specification |
|---|---|
| Ports | 48 x LC duplex (96 fibers) |
| Fiber mode | OM4 multimode |
| Height | 1U |
| Adapters | Modular, swappable |
| Splice tray | Built-in |
| Cable management | Side routing rings |
| Material | Cold-rolled steel, coated |
| Mounting | 19-inch rack |
| Rate | 10G/40G short reach |
| Routing | Natural bend, strain relief |
4. Reference Prices
KTR-LC48D 48-port LC duplex OM4 panel (adapters + tray): USD 67~108 (ref. CNY 480~780)
LC duplex OM4 adapter module (spare): USD 11~21 (ref. CNY 80~150)
Splice pigtail + heat-shrink kit: USD 8~17 (ref. CNY 60~120)
Reference only; final quote applies. 1-year warranty. Bulk pricing available. Certificate and manual included. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Fiber backbone termination in telecom rooms.
- Cabinet-to-switch patching.
- 10G/40G multimode links.
- High-density fiber cabling in data centers.
- Fiber expansion and patch management.
6. Installation & Maintenance
Installation
- Fix the panel in a 1U rack position.
- Enter the cable from the rear, anchor the strength member.
- Splice pigtails to the cable in the tray.
- Coil slack with radius >=30 mm.
- Fit the adapter plates on the front.
- Route cords through side rings.
- Label ports and far-end locations.
Maintenance
- Tidy patch cords quarterly; remove slack.
- Clean end faces with an alcohol pen.
- Check pigtail bend radius in the tray.
- Cap spare ports.
- Sample-test link loss yearly.
7. FAQ
- Q: Can OM4 and OM3 be mixed?
A: A: They mate physically, but keep one mode on high-speed links; mixing limits reach and adds loss. Standardize on OM4 for new builds. - Q: How many fibers is 48 duplex?
A: A: 48 LC duplex ports, two fibers each, = 96 fibers. Size the cable by actual fibers plus spares. - Q: Do I need a manager?
A: A: The panel has side rings; for dense cords add a 1U manager above to keep routing neat and bend radius safe. - Q: Field splice or pre-terminated?
A: A: Field splice where lengths are uncertain and flexible; pre-terminate where lengths are fixed and schedule is tight for plug-and-play quality.
8. Trend & Selection
Data-center fiber trends toward density, with 48-port LC duplex 1U panels and MPO pre-termination complementing each other, and OM4/OM5 multimode alongside OS2 single-mode. Panels move from fixed to modular adapters swappable between LC/SC/MPO on site, cutting retrofit cost. Size ports by cabinet density, standardize mode, reserve spare fibers, and bundle the splice tray, manager and labeling.
9. Delivery & Service
KITOZER ships KTR-LC48D with 1U panel, LC duplex OM4 adapter modules, built-in splice tray, rack ears, certificate and manual. Pigtails and heat-shrink kits are supplied as required.
10. Notes
A common mistake is right-angle bending of patch cords at the panel. Tight bends against the rack accumulate macro-bend loss over time; side rings exist to protect bend radius.