ToggleKITOZER KTR-LCAPC14 Fiber Adapter / LC Duplex APC OM3
Brand: KITOZER Series: KTR-LCAPC14 Category: Data Center Engineering / Fiber Adapter
fiber adapterLC duplexAPCOM3multimodeKTR-LCAPC14
1. Overview
KITOZER KTR-LCAPC14 is an LC duplex APC OM3 fiber adapter (also called coupler or flange), a passive part for mating two fiber jumpers. It mounts on fiber patch panels, termination boxes or wall outlets: an LC plug inserts from each side for a low-loss optical connection. LC duplex integrates receive (Rx) and transmit (Tx) LC ports side by side, matching dual-cord optical-module jumpers; LC is small and dense, suiting high-density patch panels.
KTR-LCAPC14 uses APC (Angled Physical Contact) polished end faces and a zirconia ceramic sleeve. APC is an 8-degree angle polish (green housing) that directs reflected light into the cladding rather than back to the source, giving high return loss (>=60 dB), good for analog video, PON and demanding links. The precision-bore sleeve aligns cores closely, keeping insertion loss low (<=0.3 dB). OM3 suits 50/125 um multimode fiber, supporting 10G and compatible with OM3/OM4 cords. The flame-retardant housing includes dust caps; panel snaps fit standard LC cutouts.
In data center low-voltage cabling, adapters are everywhere: dozens per patch panel, hundreds per room. Though cheap, their loss and return-loss metrics directly affect link quality. KTR-LCAPC14 is supplied in volume as an APC-end-face baseline passive part with consistency and field replaceability.
2. Key Features
LC duplex density
- Rx/Tx dual cores side by side.
- Snap-in panel mounting.
- Dust caps seal unused ports.
APC angled end face
- 8-degree angle polish, green.
- Return loss >=60 dB.
- Reflectance into cladding protects source.
Ceramic sleeve
- Zirconia sleeve, precision bore.
- Insertion loss <=0.3 dB.
- Mates with LC/APC cords.
OM3 compatible
- Fits 50/125 um multimode.
- Compatible with OM3/OM4 cords.
- Supports 10G.
3. Specifications
| Item | KTR-LCAPC14-D | KTR-LCAPC14-S(Simplex) | KTR-LCAPC14-24(Distribution Frame) |
|---|---|---|---|
| Interface Type | LCDuplex | LCSimplex | 24 PortsLCDuplex Panel |
| End Face Polishing | APC(Green) | APC(Green) | APC(Green) |
| Fiber Type | OM3Multi Mode | OM3Multi Mode | OM3Multi Mode |
| Insertion Loss(dB) | NotHighAt0.3 | NotHighAt0.3 | NotHighAt0.3 |
| Return Loss(dB) | NotLowAt60 | NotLowAt60 | NotLowAt60 |
| SetCylinderMaterial | Zirconia Ceramic | Zirconia Ceramic | Zirconia Ceramic |
| Insertion Life(Times) | NotLowAt500 | NotLowAt500 | NotLowAt500 |
| Flame Retardant Rating | UL94 V-0 | UL94 V-0 | UL94 V-0 |
4. Reference Prices
KTR-LCAPC14-D LCDuplexAPC OM3Adapter(Ceramic Ferrule、Green、Dust Cap): Reference USD 1~2 / unit (ref. CNY 6~15 at ~7.2)
KTR-LCAPC14-24 24 PortsLCDuplexAPC OM3Distribution Frame(IncludingAdapter、Rack1U): Reference USD 53~94 / unit (ref. CNY 380~680 at ~7.2)
Reference only; by quantity with volume discounts. Sold individually or as a populated patch panel. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Fiber patch panel ports in data centers.
- 10G module jumper mating.
- Fiber termination boxes in telecom rooms.
- Links with high return-loss demands (video/PON).
- 10G Ethernet and storage fiber links.
6. Installation & Maintenance
Installation
- Confirm standard LC duplex cutout.
- Snap adapter into panel in the right orientation.
- Remove dust cap; insert LC cord until click.
- Keep dust caps on unused ports.
- APC cords are green; do not mix with blue UPC.
- Test link loss with source and power meter.
Maintenance
- Check dust caps are in place.
- Plug/unplug by the connector, never pull the cord.
- Clean dirty end faces with a fiber cleaner pen.
- Replace adapters whose loss rises.
- Dust patch panels periodically.
7. FAQ
- Q: Can APC and UPC mate?
A: Not recommended. APC is 8-degree angled, UPC spherical; mating them scratches end faces and raises loss. Keep end-face types consistent on a link. - Q: Why is APC green?
A: Green is the industry color for APC; blue is UPC, beige is PC. Housing color tells the end-face type. - Q: Is APC necessary on OM3?
A: Usually 10G multimode uses UPC; choose APC where return loss matters (video, PON, long reach). Confirm module support on multimode APC. - Q: What loss is normal?
A: Insertion loss <=0.3 dB is normal; over 0.5 dB means a dirty end face or worn sleeve — clean or replace.
8. Trend & Selection
Data centers move to 40G/100G and multimode upgrades OM3 to OM4/OM5, but LC duplex adapters remain the dense baseline mating parts, emphasizing low loss, consistency, flame retardance and cleanability. APC use rises where return loss matters. Keep end-face type consistent (UPC/APC), choose LC duplex for density and OM3 for the link; buy in volume for consistency; a populated panel is convenient.
9. Delivery & Service
KITOZER supplies LC duplex APC OM3 adapters in volume, pre-assembled on 24/48-port 1U/2U rack panels. We provide insertion-loss test reports. Delivery includes adapters, dust caps and panel snaps; populated panels include rack and cable management. Warranty covers adapters with abnormal loss.
10. Additional Notes
The most common cabling mistake is mixing APC and UPC. A green APC cord into a blue UPC adapter wedges angle against sphere: it links but with high loss, and after a few mates the face scratches and errors rise. Separate by color and keep the whole link consistent.
Another pitfall: saving money on cheap sleeves. A zirconia sleeve replaced by plastic or low-precision metal pushes insertion loss from 0.3 dB to over 0.6 dB; across dozens of ports the accumulated loss is large. Adapters are cheap, but the sleeve must be ceramic.
Selection summary: LC duplex for dual-core modules; green APC for high return loss, blue UPC for normal multimode; keep end faces consistent; ceramic sleeve for low loss; keep dust caps on; clean port by port. The adapter is the optical outlet — clean and aligned, and the signal runs steady.