KITOZER
KITOZER

KITOZER LC duplex APC OM3 adapter

KITOZER KTR-LCAPC14 Fiber Adapter / LC Duplex APC OM3

Brand: KITOZER Series: KTR-LCAPC14 Category: Data Center Engineering / Fiber Adapter

fiber adapterLC duplexAPCOM3multimodeKTR-LCAPC14

1. Overview

KITOZER KTR-LCAPC14 is an LC duplex APC OM3 fiber adapter (also called coupler or flange), a passive part for mating two fiber jumpers. It mounts on fiber patch panels, termination boxes or wall outlets: an LC plug inserts from each side for a low-loss optical connection. LC duplex integrates receive (Rx) and transmit (Tx) LC ports side by side, matching dual-cord optical-module jumpers; LC is small and dense, suiting high-density patch panels.

KTR-LCAPC14 uses APC (Angled Physical Contact) polished end faces and a zirconia ceramic sleeve. APC is an 8-degree angle polish (green housing) that directs reflected light into the cladding rather than back to the source, giving high return loss (>=60 dB), good for analog video, PON and demanding links. The precision-bore sleeve aligns cores closely, keeping insertion loss low (<=0.3 dB). OM3 suits 50/125 um multimode fiber, supporting 10G and compatible with OM3/OM4 cords. The flame-retardant housing includes dust caps; panel snaps fit standard LC cutouts.

In data center low-voltage cabling, adapters are everywhere: dozens per patch panel, hundreds per room. Though cheap, their loss and return-loss metrics directly affect link quality. KTR-LCAPC14 is supplied in volume as an APC-end-face baseline passive part with consistency and field replaceability.

2. Key Features

LC duplex density

  • Rx/Tx dual cores side by side.
  • Snap-in panel mounting.
  • Dust caps seal unused ports.

APC angled end face

  • 8-degree angle polish, green.
  • Return loss >=60 dB.
  • Reflectance into cladding protects source.

Ceramic sleeve

  • Zirconia sleeve, precision bore.
  • Insertion loss <=0.3 dB.
  • Mates with LC/APC cords.

OM3 compatible

  • Fits 50/125 um multimode.
  • Compatible with OM3/OM4 cords.
  • Supports 10G.

3. Specifications

Item KTR-LCAPC14-D KTR-LCAPC14-S(Simplex) KTR-LCAPC14-24(Distribution Frame)
Interface Type LCDuplex LCSimplex 24 PortsLCDuplex Panel
End Face Polishing APC(Green) APC(Green) APC(Green)
Fiber Type OM3Multi Mode OM3Multi Mode OM3Multi Mode
Insertion Loss(dB) NotHighAt0.3 NotHighAt0.3 NotHighAt0.3
Return Loss(dB) NotLowAt60 NotLowAt60 NotLowAt60
SetCylinderMaterial Zirconia Ceramic Zirconia Ceramic Zirconia Ceramic
Insertion Life(Times) NotLowAt500 NotLowAt500 NotLowAt500
Flame Retardant Rating UL94 V-0 UL94 V-0 UL94 V-0

4. Reference Prices

KTR-LCAPC14-D LCDuplexAPC OM3Adapter(Ceramic Ferrule、Green、Dust Cap): Reference USD 1~2 / unit (ref. CNY 6~15 at ~7.2)

KTR-LCAPC14-24 24 PortsLCDuplexAPC OM3Distribution Frame(IncludingAdapter、Rack1U): Reference USD 53~94 / unit (ref. CNY 380~680 at ~7.2)

Reference only; by quantity with volume discounts. Sold individually or as a populated patch panel. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Fiber patch panel ports in data centers.
  • 10G module jumper mating.
  • Fiber termination boxes in telecom rooms.
  • Links with high return-loss demands (video/PON).
  • 10G Ethernet and storage fiber links.

6. Installation & Maintenance

Installation

  • Confirm standard LC duplex cutout.
  • Snap adapter into panel in the right orientation.
  • Remove dust cap; insert LC cord until click.
  • Keep dust caps on unused ports.
  • APC cords are green; do not mix with blue UPC.
  • Test link loss with source and power meter.

Maintenance

  • Check dust caps are in place.
  • Plug/unplug by the connector, never pull the cord.
  • Clean dirty end faces with a fiber cleaner pen.
  • Replace adapters whose loss rises.
  • Dust patch panels periodically.

7. FAQ

  • Q: Can APC and UPC mate?
    A: Not recommended. APC is 8-degree angled, UPC spherical; mating them scratches end faces and raises loss. Keep end-face types consistent on a link.
  • Q: Why is APC green?
    A: Green is the industry color for APC; blue is UPC, beige is PC. Housing color tells the end-face type.
  • Q: Is APC necessary on OM3?
    A: Usually 10G multimode uses UPC; choose APC where return loss matters (video, PON, long reach). Confirm module support on multimode APC.
  • Q: What loss is normal?
    A: Insertion loss <=0.3 dB is normal; over 0.5 dB means a dirty end face or worn sleeve — clean or replace.

8. Trend & Selection

Data centers move to 40G/100G and multimode upgrades OM3 to OM4/OM5, but LC duplex adapters remain the dense baseline mating parts, emphasizing low loss, consistency, flame retardance and cleanability. APC use rises where return loss matters. Keep end-face type consistent (UPC/APC), choose LC duplex for density and OM3 for the link; buy in volume for consistency; a populated panel is convenient.

9. Delivery & Service

KITOZER supplies LC duplex APC OM3 adapters in volume, pre-assembled on 24/48-port 1U/2U rack panels. We provide insertion-loss test reports. Delivery includes adapters, dust caps and panel snaps; populated panels include rack and cable management. Warranty covers adapters with abnormal loss.

10. Additional Notes

The most common cabling mistake is mixing APC and UPC. A green APC cord into a blue UPC adapter wedges angle against sphere: it links but with high loss, and after a few mates the face scratches and errors rise. Separate by color and keep the whole link consistent.

Another pitfall: saving money on cheap sleeves. A zirconia sleeve replaced by plastic or low-precision metal pushes insertion loss from 0.3 dB to over 0.6 dB; across dozens of ports the accumulated loss is large. Adapters are cheap, but the sleeve must be ceramic.

Selection summary: LC duplex for dual-core modules; green APC for high return loss, blue UPC for normal multimode; keep end faces consistent; ceramic sleeve for low loss; keep dust caps on; clean port by port. The adapter is the optical outlet — clean and aligned, and the signal runs steady.