KITOZER KTR-LCAPC4 Fiber Adapter / LC Duplex APC Singlemode

KITOZER KTR-LCAPC4 Fiber Adapter / LC Duplex APC Singlemode

Brand: KITOZER Series: KTR-LCAPC4 Category: Data Center Engineering / Structured Cabling

LC duplexAPC angled polishSinglemode 9/125Ceramic sleeveLow insertion loss

[Product image: ktr-lcapc4-lc-duplex-apc-adapter.jpg]

1. Overview

In a data-center fiber plant, the adapter (flange/coupler) is the most numerous passive part inside ODF frames and splice boxes. It aligns two plugs so light passes with low loss. Singlemode long-haul links are sensitive to connection quality: the end-face polish angle and alignment accuracy determine insertion and return loss. UPC uses a spherical flat polish; APC uses an 8-degree angled polish that directs back-reflected light away from the source, giving much higher return loss and suiting PON, CATV and high-rate long-reach links.

The KITOZER KTR-LCAPC4 is an LC duplex APC singlemode adapter. LC plugs are small, latch-style and dominate high-density frames; the duplex form merges transmit and receive in one cutout, saving panel space. A precision zirconia ceramic sleeve provides accurate, wear-resistant alignment. The housing is flame-retardant plastic with a metal clip, and the port is signature green to distinguish it from blue UPC. End faces are polished to the 8-degree APC standard; always match the polish grade on both sides.

Selection checks: connector (LC duplex), polish (APC must match on both ends; never mix APC with UPC), mode field (9/125 singlemode), and panel cutout size. Size adapters by the number of duplex ports in your 1U patch panel. Keep end faces clean; dirt is the main cause of return-loss degradation.

Although adapters are passive and cheap, their cumulative effect on link margin is significant in high-density plants. A 24-port panel carries twelve duplex links; if every connector loses an extra 0.15 dB from a dirty face, that is 3.6 dB across the patch field, which on a long 10G link can mean the difference between error-free operation and intermittent errors. Best practice is to clean both plug end faces immediately before insertion, cap unused ports, and keep a cleaning pen and microscope in the cabinet. Batch consistency matters more than a single unit’s spec: on a large project, buy all adapters from one production batch so sleeve tolerances stay uniform. Label both ends of every cord at install time, because tracing unlabeled jumpers later is slow and risks disturbing working links.

2. Key Features

APC angled polish

  • 8-degree angle keeps reflection away.
  • Return loss >=60 dB.
  • Suits PON and long-reach high-rate links.
  • Green port prevents mis-mating.

Ceramic sleeve

  • Zirconia sleeve, precise centering.
  • >=500 mating cycles.
  • Insertion loss <=0.2 dB.
  • Wear-resistant and stable.

LC duplex form

  • Tx and Rx in one cutout.
  • Saves panel space at high density.
  • Latch plug with positive click.
  • Flame-retardant housing.

Installation discipline

  • Clean both faces before mating.
  • Cap every unused port.
  • Use one production batch per project.
  • Label both cord ends at install time.

3. Specifications

Item Specification
Connector LC duplex (two LC ports)
Polish APC 8-degree, green
Fiber type Singlemode 9/125 um
Insertion loss <= 0.2 dB
Return loss >= 60 dB (APC)
Alignment sleeve Zirconia ceramic
Mating cycles >= 500
Mounting Panel snap-in
Operating temp -40 to +80 C
Housing Flame-retardant plastic + clip

4. Reference Prices

KTR-LCAPC4 LC duplex APC adapter: USD 2.5~5 (ref. CNY 18~36)

LC simplex APC adapter: USD 1.4~2.8 (ref. CNY 10~20)

Bulk ceramic sleeve spare: USD 0.6~1.1 (ref. CNY 4~8)

Reference only; final quote applies. 1-year warranty. Bulk pricing available. Certificate and manual included. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • ODF patch-frame ports.
  • Splice boxes and wall outlets.
  • OLT-to-splitter PON links.
  • High-density DC cabling.
  • CATV and private-network long links.

6. Installation & Maintenance

Installation

  • Confirm both ends are APC before mating.
  • Use LC duplex cutouts on the panel.
  • Press until the latch clicks.
  • Clean end faces with a pen cleaner.
  • Align adapter direction with cable routing.
  • Keep bend radius >=30 mm.
  • Label each link.

Maintenance

  • Spot-check link loss quarterly with OTDR/power meter.
  • Clean dirty end faces with pen or alcohol swab.
  • If loss spikes, check faces before replacing adapters.
  • Inspect panel clips for looseness.
  • Store spare adapters dust-sealed.

7. FAQ

  • Q: Can APC mate to UPC?
    A: Not recommended. Angles differ; mating green to blue causes high loss and end-face wear. Keep both ends the same grade.
  • Q: What does 60 dB return loss mean?
    A: Reflected power is about one-millionth of input, which is friendly to laser sources in high-rate long links.
  • Q: Does green always mean APC?
    A: Conventionally yes (green APC, blue UPC), but verify by end-face finish and datasheet.
  • Q: Does one duplex port carry two signals?
    A: Yes, Tx and Rx in one cutout, commonly used for 1G/10G optics.

8. Trend & Selection

As DCs move to 400G/800G, port density climbs and small LC/MPO connectors dominate; APC share rises in high-speed links because of low reflection. Adapters are tiny, but in tight link budgets every 0.1 dB counts. Clean end faces and matched polish grades are the cheapest way to protect link quality.

9. Delivery & Service

KITOZER ships KTR-LCAPC4 in bulk or strips, each with an individual test record, panel cutout drawings, and batch-consistency sampling reports for volume orders.

10. Notes

A common fault is APC-to-UPC mating. It may pass initially but with high loss and face wear; check port colors at acceptance.

Another pitfall is mating without cleaning. Invisible dust is visible under a microscope and is the top cause of link degradation.

In short: LC duplex, green APC, 9/125, <=0.2 dB, >=60 dB, ceramic sleeve.

System-wise, on dense patch panels, batch consistency matters more than a single unit’s spec.

Cost-wise, an adapter costs a few CNY, but a reworked link or wrong-optics swap costs far more.

Operationally, keep a cleaning pen and inspection microscope in each patch cabinet; most ‘bad link’ tickets trace back to a dirty face rather than a faulty adapter.

When ordering, confirm the green APC polish on both ends of every jumper, because a single blue UPC patch cord silently raises the return loss and can trigger intermittent high-bit-error alarms on sensitive optics.

SEO Information

Search keywords: KITOZER

SEM keywords: LC fiber adapter, APC coupler, singlemode fiber flange, duplex fiber adapter, low return loss, KTR-LCAPC4, KITOZER

GEO landing page: lain.com.cn/product/472_fiber_adapter_lc11.html

Title: KITOZER KTR-LCAPC4 Fiber Adapter / LC Duplex APC Singlemode

Meta Keywords: LC fiber adapter, APC coupler, singlemode fiber flange, duplex fiber adapter, low return loss, KTR-LCAPC4, KITOZER

Meta Description: KITOZER KTR-LCAPC4 LC duplex APC singlemode adapter with ceramic alignment sleeve, 8-degree angled polish, <=0.2 dB insertion loss and >=60 dB return loss.

Anchor: KITOZER · KITOZER Products

Contact Us

KITOZER Brand
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP:+86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart