Table of Contents
ToggleKITOZER KTR-LCSC LC-SC Duplex Fiber Patch Cord
Brand: KITOZER Series: KTR-LCSC Category: Data Center Engineering / Fiber Cabling
LC-SC duplexOM3/OM4LSZHlow ILKTR-LCSC
1. Overview
Fiber patch cords are the most-used connector in a data center — every optical module ends with one, and a medium-sized room needs tens of thousands. LC connectors are half the size of SC and dominate server/switch SFP ports; SC connectors latch firmly and dominate ODF patch panels. The bridge between them is the LC-SC duplex cord: LC into the module, SC into the panel.
The KITOZER KTR-LCSC series offers OM3 (10 Gb/s to 300 m), OM4 (10/40 Gb/s to 550 m) and OS2 singlemode (10 km+). Duplex send/receive design, 2.0 mm tight-buffered fiber, LSZH jacket rated B1 flame. Ceramic ferrules are PC/UPC polished, with 8° APC optional for CATV/analog. Insertion loss ≤0.3 dB, return loss ≥50 dB (UPC). Standard lengths 1~30 m, custom 50/100 m available.
Selection: mode (orange=OM1, aqua=OM3/OM4, yellow=OS2 — never mix by color); connector (LC-SC duplex, one send one receive, not simplex); jacket (LSZH for room risers); and length (leave 1~2 m slack, avoid overlong coiling). Minimum bend radius is 10× cable diameter.
2. Key Features
Optical
- Ceramic ferrule, UPC/APC polish
- Insertion loss ≤0.3 dB
- Return loss ≥50 dB (UPC)
- End-face geometry fully inspected
Cable & jacket
- OM3/OM4 aqua, OS2 yellow
- 2.0 mm tight-buffered duplex
- LSZH, B1 flame rated
- Tensile and crush resistant
Compatibility
- LC small form into modules
- SC square into panels
- Duplex send/receive
- Fits SFP/SFP+/QSFP
3. Specifications
| Item | KTR-LCSC-S1 | KTR-LCSC-S2 | KTR-LCSC-S3 |
|---|---|---|---|
| 光纤类型 | OM3多模 | OM4多模 | OS2单模 |
| 护套颜色 | 水蓝色 | 水蓝色 | 黄色 |
| 传输距离(10G) | 300 m | 550 m | 10 km+ |
| 插入损耗 | ≤0.3 dB | ≤0.3 dB | ≤0.3 dB |
| 回波损耗 | ≥50 dB | ≥50 dB | ≥50 dB(UPC) |
| 护套外径 | 2.0 mm | 2.0 mm | 2.0 mm |
| 最小弯曲半径 | 30 mm | 30 mm | 30 mm |
| 常用长度 | 1/3/5/10 m | 1/3/5/10 m | 1/3/5/10/20/30 m |
4. Reference Prices
KTR-LCSC-OM3-3M LC-SC OM3 duplex (3 m)::Reference Reference USD 2.5~4.4 / pc (ref. CNY 18~32 at ~7.2)
KTR-LCSC-OM4-3M LC-SC OM4 duplex (3 m)::Reference Reference USD 3.9~6.7 / pc (ref. CNY 28~48 at ~7.2)
KTR-LCSC-OS2-5M LC-SC OS2 simplex (5 m)::Reference Reference USD 3~5.3 / pc (ref. CNY 22~38 at ~7.2)
Custom length (per meter add-on)::Reference Reference USD 0.4~0.8 / m (ref. CNY 3~6 at ~7.2)
Reference only; priced by mode and length. 100-pc carton pricing on request. 1-year warranty. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Server SFP+ to ODF patch panel.
- Switch-to-server fiber links.
- In-rack jumpers to top-of-rack.
- Inter-building singlemode backbones.
- IP camera fiber backhaul.
6. Deployment & Implementation
Installation
- Grip the boot, never pull the cable
- Latch LC/SC after insertion
- Bend radius ≥30 mm, no foot traffic
- Label at boot, not over the latch
Operations
- Quarterly visual fault locator test
- Clean end face with pen cleaner
- Inspect ferrule after 100 insertions
- Spare cords by length bracket
7. FAQ
- Q: OM3 vs OM4?
A: OM3 suffices for 10G up to 300 m. OM4 covers 25/40/100G or 300~550 m. OM4 is backward-compatible; specify OM4 for new plants. - Q: Can singlemode and multimode mate?
A: No — mode field diameters differ (9/125 vs 50/125), causing huge loss. Must match modes. Yellow = singlemode, aqua = multimode. - Q: APC or UPC?
A: Use UPC (blue) for all digital data-center links. APC (green) is for CATV/analog and has an 8° angle; mating APC with UPC causes high loss. - Q: Can a broken cord be spliced?
A: Field fusion adds 0.1~0.3 dB per splice. Patch cords are factory-terminated; replace whole cords rather than splicing.
8. Trend & Selection
Patch cords are moving from duplex to MPO/MTP high-density pre-terminated trunks. 40/100/400 G uses MPO12/MPO24 trunks, pushing LC-SC duplex to the equipment edge. OM5 wideband supports SWDM wavelength multiplexing. Pre-terminated cables and modular panels dominate new builds; LC-SC duplex remains the workhorse for existing equipment replacement.
9. Delivery & Service
KITOZER supplies KTR-LCSC by mode (OM3/OM4/OS2), length (1~30 m stock, 50/100 m custom) and polish (UPC/APC). Each cord is insertion-loss tested with report. Matched labels both ends. 1-year warranty; batch projects can add MPO trunks, cleaning kits and label printers.
10. Additional Notes
The #1 mistake is using multimode for singlemode. Yellow and aqua look similar; wrong cords leave the LINK dark or drop to 1 Gb/s. Verify by color and label at picking.
The second pitfall is tight coiling. Spare length coiled into a 10 cm loop breaks the bend radius and spikes loss. Route spare straight or in a large loop (≥30 cm).
The third blunder is dirty end faces. Fingerprints and dust are the top cause of 10 Gb/s errors. One pen-clean before insertion prevents 80% of link issues.
Selection summary: mode by distance, connector by equipment, leave slack without tight coils, clean end faces. Small parts, but tens of thousands of them determine network reliability.
SEO Information
Search keywords:KTR-LCSCKITOZERLC-SC Duplex Fiber Patch Cord
SEM keywords:LC-SC patch cord,duplex fiber,LC to SC,OM3 multimode,jumper,KTR-LCSC,KITOZER
GEO landing page:lain.com.cn/product/ktr-lcsc-lc_sc_cord.html
Title:KITOZER KTR-LCSC LC-SC Duplex Fiber Patch Cord
Meta Keywords:LC-SC patch cord,duplex fiber,LC to SC,OM3 multimode,jumper,KTR-LCSC,KITOZER
Meta Description:KITOZER KTR-LCSC LC-SC duplex fiber patch cord, OM3/OM4 multimode or OS2 singlemode, LSZH, IL ≤0.3 dB, 1~30 m.
Anchor: KITOZER by Guangzhou Laian · LC-SC Duplex Fiber Patch Cord
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com