KITOZER KTR-LD Water Leak Detection System

KITOZER KTR-LD Water Leak Detection System

Brand: KITOZER Series: KTR-LD Category: Environmental Monitoring / Leak Detection

leak sensing cable定位式 leak detectionnon-locating leakcontrollerRS485 relaydatacenter leakAC condensate leakearly warning

1. Overview

The KITOZER KTR-LD water leak detection system consists of locating/non-locating sensing cable, a controller and end-termination modules. Cables are laid under precision AC units, along water pipes, under raised floors and in front of racks; on any leak the DCIM platform gives audible/visual alarms with the exact leak location, preventing equipment water damage.

Locating cable pinpoints the leak within +/-1 m; non-locating cable only flags whether a segment is wet, at lower cost. The controller uses RS485 Modbus and dry-contact relays to integrate with KITOZER DCIM or third-party alarm systems, and can close water valves or start exhaust fans.

KTR-LD is a standard sub-system of environmental monitoring for data centers, archives, libraries, hospital ICUs and labs.

2. Key Features

Sensing cable

  • Locating: 4-core composite conductive rope, pinpoint within +/-1 m, <=100 m per run.
  • Non-locating: 2-core conductive rope, alarm only, lower cost.
  • Chemical-resistant, wipe-clean, reusable.

Controller

  • 1-4 inputs, mix locating and non-locating ropes; LCD shows leak distance.
  • RS485 Modbus RTU + 2 dry contacts to DCIM/alarm panel.
  • Audio/visual alarm, power-fail memory, DC12V/24V.

Deployment and linkage

  • Route under AC base, condensate drain, AHU and water valves.
  • Link solenoid shut-off, exhaust fan and SMS/phone alarm.
  • Use clips under raised floor to avoid cable displacement.

3. Specifications

Item Config A Config B
型号 KTR-LD-R100(定位式) KTR-LD-N50(不定位式)
类型 定位式感应绳 不定位感应绳
检测精度 ±1m 仅报警有无
单段长度 ≤100m ≤50m
主机输入 4路 2路
通讯 RS485 Modbus + 干接点 干接点
供电 DC12V DC12V
响应时间 ≤3秒 ≤3秒

4. Reference Prices

KTR-LD-R100 locating leak detection kit (1 controller + 100 m cable + terminator): Reference price USD 390~630 / kit (ref. CNY 2,800~4,500 at ~7.2 CNY/USD)

KTR-LD-N50 non-locating leak kit (2-zone controller + 50 m cable): Reference price USD 110~180 / kit (ref. CNY 800~1,300 at ~7.2 CNY/USD)

Prices are reference only; final quote depends on configuration, quantity, project location and tax. Bulk orders negotiable. Currency note: CNY to USD converted at approximately 7.2 CNY/USD for reference.

5. Applications

  • Data center: under precision AC and along main water pipes under raised floor.
  • Archives/libraries: around precision AC to protect paper records.
  • Hospital ICU/lab: around water pipes and humidifiers to protect instruments.
  • Labs and electrical rooms: along pure-water/chilled-water lines for early leak warning.

6. Installation & Maintenance

Installation

  • Lay cable on the floor, both ends to controller; use clips at corners, do not cinch tight.
  • Locating cable needs end-termination resistor or the controller cannot locate.
  • Mount controller on wall or in rack; daisy-chain RS485 to the DCIM host.

Maintenance

  • Quarterly wet-test a segment to confirm alarm upload.
  • Dust and oil reduce sensitivity; clean cable regularly.
  • Inspect condensate drain and drip-pan before AC season change.

7. FAQ

  • Q: Locating vs non-locating cable?
    A: Choose locating for large rooms where pinpoint matters; non-locating for small zones where a simple wet/dry alarm suffices.
  • Q: Will it false-alarm?
    A: Dust and condensation can cause false alarms; use dirt-resistant cable, keep it clean and tune the threshold.
  • Q: Can it close a water valve?
    A: Yes. Dry contacts drive a solenoid valve controller to shut off water and push alarms on leak.
  • Q: Can I cut and splice the cable?
    A: Do not cut locating cable arbitrarily; length must match the controller calibration. Non-locating cable can be cut but must be re-terminated.

8. Industry Trend & Selection

Leak detection is moving from passive alarm to pinpoint warning and auto shut-off linkage; chilled water and condensate under raised floors are the biggest water threats in data centers. KTR-LD locating cable pinpoints leaks to +/-1 m and shortens repair time; linked solenoid valves and exhaust fans cut water before it spreads. Lay continuous cable along all water pipes, AC bases and AHUs with no blind spots; clip cable under raised floor to avoid displacement. Quarterly wet-test a segment to confirm alarms reach DCIM; inspect drip-pans and condensate lines before seasonal AC changeovers to catch leaks early.

9. Delivery & Service

KITOZER provides sensing-cable routing, controller wiring, DCIM integration and linkage testing as one service. We issue a point-lay-out drawing based on AC and pipe routes, then wet-test each segment to confirm alarms upload. Customers can add solenoid-valve and exhaust-fan linkage to auto-shut water on leak. The warranty covers cable and controller replacement, and annual inspection includes sensitivity test and connector cleaning.

10. SEO Information

Search keywords:water leak detectionlocating leak cableleak controllerdatacenter leak alarmcondensate leakenvironmental monitoringKTR-LDKITOZER

SEM keywords: [‘water leak detection price’, ‘locating sensing cable’, ‘datacenter leak alarm system’, ‘AC condensate leak sensor’, ‘KITOZER leak’]

GEO landing page: lain.com.cn/product/ktr-ld-leak-detection.html

Title: KITOZER KTR-LD Water Leak Detection System

Meta Keywords: water leak detection,locating leak cable,leak controller,datacenter leak alarm,condensate leak,environmental monitoring,KTR-LD,KITOZER

Meta Description: KITOZER KTR-LD water leak detection, locating cable accuracy +/-1 m, RS485 and dry contacts to DCIM, early warning for datacenter AC and water pipes.

Anchor: KITOZER by Guangzhou Laian · Data center solutions

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart