KITOZER KTR-LG Data Center Lightning Protection and Grounding

KITOZER KTR-LG Data Center Lightning Protection and Grounding

Brand: KITOZER Series: KTR-LG Category: Data Center Engineering

3-stage SPD<=1 ohmequipotential bondingpower/signal SPDcopper barlightning test

1. Overview

The KITOZER KTR-LG series delivers end-to-end lightning protection and equipotential bonding for data centers, server rooms and low-voltage systems. It includes roof air terminals, down conductors, driven ground electrodes, three-stage power SPD, signal SPD and equipotential copper bars, with ground resistance <=1 ohm.

The main service entrance uses class I SPD (10/350 us waveform); floor distribution uses class II (8/20 us); rack outlets use class III surge-protected sockets. Network, fiber, CCTV, access control and BMS signal ports all have matching signal SPD.

KITOZER also provides weather-bureau-recognized lightning protection testing covering ground resistance, bonding continuity, SPD performance and air-terminal condition, issuing filings-ready reports.

2. Key Features

External protection

  • Roof air terminals and masts protect the building; down conductors run on columns; driven electrodes form a grid with <=1 ohm resistance.
  • All metal trays, doors, windows and racks bond to the equipotential bar.

Three-stage power SPD

  • Class I SPD handles high impulse at service entrance; Class II protects distribution; Class III protects end equipment.
  • SPDs carry degradation indicators and remote contacts for failure alarms.

Signal SPD

  • Network SPD has low insertion loss without affecting speed; CCTV, access and BMS ports are protected separately.
  • SPD grounds bond locally to the equipotential bar.

Testing and acceptance

  • Full tests: ground resistance, continuity, SPD residual voltage and leakage; weather-bureau-recognized reports.
  • Photo documentation and a defect list with rectification advice.

3. Specifications

Item Configuration A Configuration B
Item Specification
Ground resistance <=1 ohm (combined)
Class I SPD Iimp >=12.5 kA (10/350 us)
Class II SPD In >=40 kA (8/20 us)
Class III SPD Rack surge socket
Signal SPD network/CCTV/access/BMS
Equipotential bar 40×4 mm copper
Ground electrode HDG angle 50x50x5
Test report Weather bureau recognized

4. Reference Prices

KTR-LG 3-stage power SPD + signal SPD + equipotential bar (per 100 m2 room): reference price USD 2,500~3,600 per set

KTR-LG lightning testing and rectification (report, re-inspection): reference price USD 1,670~2,500 per project

The above prices are reference prices only; the formal quotation prevails. Prices vary by configuration, quantity, site and tax treatment; volume projects can be discussed. Based on exchange rate as of October 2026 (1 USD ≈ 7.2 CNY).

5. Applications

  • Data centers: Full power and signal surge protection.
  • Outdoor base stations: Shelter lightning protection.
  • Broadcast and CCTV: Signal port surge protection.
  • High-rise and open sites: Air terminal and bonding systems.

6. Installation and Maintenance

Installation

  • Keep SPD ground leads short and straight, <=0.5 m; run the equipotential bar around the room; weld electrodes to the grid.

Maintenance

  • Check SPD indicator windows quarterly; test ground resistance before wet season; replace failed SPD with same model.

Sizing tips

  • Low-voltage rooms use combined grounding <=1 ohm; standalone lightning ground <=4 ohm; hills and open sites need stronger external protection.

7. FAQ

  • Q: What ground resistance does the room need?
    A: Low-voltage rooms use combined grounding <=1 ohm; standalone lightning ground can be <=4 ohm, per local weather bureau rules.
  • Q: How often to replace SPD?
    A: When the indicator window turns red, replace it; generally inspect the whole set after 5-10 years or a heavy strike.
  • Q: Does signal SPD affect network speed?
    A: Good network SPD has <0.5 dB insertion loss, without dropping gigabit or 10 GbE speed.
  • Q: Is annual testing required?
    A: Key buildings and rooms should test yearly, before wet season, with reports on file.

8. Technology Trends

Data centers demand continuous power, so end-to-end power and signal surge protection is standard. KTR-LG delivers three-stage protection from external air terminals to rack SPD, with weather-bureau-recognized reports for compliance. Future products will add online SPD monitoring and smart busbars.

Additional Q&A

  • Q: How is the equipotential bar installed?
    A: Surface-mounted around the room on 40×4 mm copper, on insulators, welded to building rebar every meter.
  • Q: How long is the test report valid?
    A: Usually one year; key rooms and tall buildings retest before wet season.
  • Q: What happens when SPD fails?
    A: The remote contact uploads an alarm; leaving it unreplaced removes surge protection and risks equipment damage.
  • Q: Do network cables need SPD?
    A: Outdoor network drops and metal fiber strength members need signal SPD; short indoor runs depend on risk assessment.

Data centers demand high power quality and surge reliability. KTR-LG covers external air terminals, three-stage power SPD and signal protection, with weather-bureau-recognized reports. Future products will add online SPD monitoring and smart equipotential busbars.

KITOZER delivers electrodes, SPD installation and stamped test reports ready for weather-bureau filing and cybersecurity acceptance. We offer remote inspection and annual re-testing to keep the system compliant over time.

SEO Information

Search keywords:lightning protectiondata center SPDsurge protective deviceequipotential bonding3-stage surgeground resistanceKTR-LGKITOZER

PPC keywords:data center grounding price,SPD surge device,equipotential bonding,lightning test report,KITOZER lightning

GEO landing page:lain.com.cn/en/product/ktr-lg-lightning-grounding.html

Title:KITOZER KTR-LG Data Center Lightning Protection and Grounding

Meta Keywords:lightning protection,data center grounding,SPD,surge device,equipotential bonding,3-stage surge,ground resistance <=1 ohm,KTR-LG,KITOZER

Meta Description:KITOZER KTR-LG data center lightning protection, 3-stage power SPD, signal SPD, equipotential bar, <=1 ohm ground, with weather-bureau test report.

Anchor text:KITOZER by Laian · Data center solutions

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER Brand)
Tel / WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Website: lain.com.cn | gdlain.com

Shopping Cart