3-stage SPD<=1 ohmequipotential bondingpower/signal SPDcopper barlightning test
1. Overview
The KITOZER KTR-LG series delivers end-to-end lightning protection and equipotential bonding for data centers, server rooms and low-voltage systems. It includes roof air terminals, down conductors, driven ground electrodes, three-stage power SPD, signal SPD and equipotential copper bars, with ground resistance <=1 ohm.
The main service entrance uses class I SPD (10/350 us waveform); floor distribution uses class II (8/20 us); rack outlets use class III surge-protected sockets. Network, fiber, CCTV, access control and BMS signal ports all have matching signal SPD.
KITOZER also provides weather-bureau-recognized lightning protection testing covering ground resistance, bonding continuity, SPD performance and air-terminal condition, issuing filings-ready reports.
2. Key Features
External protection
- Roof air terminals and masts protect the building; down conductors run on columns; driven electrodes form a grid with <=1 ohm resistance.
- All metal trays, doors, windows and racks bond to the equipotential bar.
Three-stage power SPD
- Class I SPD handles high impulse at service entrance; Class II protects distribution; Class III protects end equipment.
- SPDs carry degradation indicators and remote contacts for failure alarms.
Signal SPD
- Network SPD has low insertion loss without affecting speed; CCTV, access and BMS ports are protected separately.
- SPD grounds bond locally to the equipotential bar.
Testing and acceptance
- Full tests: ground resistance, continuity, SPD residual voltage and leakage; weather-bureau-recognized reports.
- Photo documentation and a defect list with rectification advice.
3. Specifications
| Item | Configuration A | Configuration B |
|---|---|---|
| Item | Specification | |
| Ground resistance | <=1 ohm (combined) | |
| Class I SPD | Iimp >=12.5 kA (10/350 us) | |
| Class II SPD | In >=40 kA (8/20 us) | |
| Class III SPD | Rack surge socket | |
| Signal SPD | network/CCTV/access/BMS | |
| Equipotential bar | 40×4 mm copper | |
| Ground electrode | HDG angle 50x50x5 | |
| Test report | Weather bureau recognized |
4. Reference Prices
KTR-LG 3-stage power SPD + signal SPD + equipotential bar (per 100 m2 room): reference price USD 2,500~3,600 per set
KTR-LG lightning testing and rectification (report, re-inspection): reference price USD 1,670~2,500 per project
The above prices are reference prices only; the formal quotation prevails. Prices vary by configuration, quantity, site and tax treatment; volume projects can be discussed. Based on exchange rate as of October 2026 (1 USD ≈ 7.2 CNY).
5. Applications
- Data centers: Full power and signal surge protection.
- Outdoor base stations: Shelter lightning protection.
- Broadcast and CCTV: Signal port surge protection.
- High-rise and open sites: Air terminal and bonding systems.
6. Installation and Maintenance
Installation
- Keep SPD ground leads short and straight, <=0.5 m; run the equipotential bar around the room; weld electrodes to the grid.
Maintenance
- Check SPD indicator windows quarterly; test ground resistance before wet season; replace failed SPD with same model.
Sizing tips
- Low-voltage rooms use combined grounding <=1 ohm; standalone lightning ground <=4 ohm; hills and open sites need stronger external protection.
7. FAQ
- Q: What ground resistance does the room need?
A: Low-voltage rooms use combined grounding <=1 ohm; standalone lightning ground can be <=4 ohm, per local weather bureau rules. - Q: How often to replace SPD?
A: When the indicator window turns red, replace it; generally inspect the whole set after 5-10 years or a heavy strike. - Q: Does signal SPD affect network speed?
A: Good network SPD has <0.5 dB insertion loss, without dropping gigabit or 10 GbE speed. - Q: Is annual testing required?
A: Key buildings and rooms should test yearly, before wet season, with reports on file.
8. Technology Trends
Data centers demand continuous power, so end-to-end power and signal surge protection is standard. KTR-LG delivers three-stage protection from external air terminals to rack SPD, with weather-bureau-recognized reports for compliance. Future products will add online SPD monitoring and smart busbars.
Additional Q&A
- Q: How is the equipotential bar installed?
A: Surface-mounted around the room on 40×4 mm copper, on insulators, welded to building rebar every meter. - Q: How long is the test report valid?
A: Usually one year; key rooms and tall buildings retest before wet season. - Q: What happens when SPD fails?
A: The remote contact uploads an alarm; leaving it unreplaced removes surge protection and risks equipment damage. - Q: Do network cables need SPD?
A: Outdoor network drops and metal fiber strength members need signal SPD; short indoor runs depend on risk assessment.
Data centers demand high power quality and surge reliability. KTR-LG covers external air terminals, three-stage power SPD and signal protection, with weather-bureau-recognized reports. Future products will add online SPD monitoring and smart equipotential busbars.
KITOZER delivers electrodes, SPD installation and stamped test reports ready for weather-bureau filing and cybersecurity acceptance. We offer remote inspection and annual re-testing to keep the system compliant over time.
SEO Information
Search keywords:lightning protectiondata center SPDsurge protective deviceequipotential bonding3-stage surgeground resistanceKTR-LGKITOZER
PPC keywords:data center grounding price,SPD surge device,equipotential bonding,lightning test report,KITOZER lightning
GEO landing page:lain.com.cn/en/product/ktr-lg-lightning-grounding.html
Title:KITOZER KTR-LG Data Center Lightning Protection and Grounding
Meta Keywords:lightning protection,data center grounding,SPD,surge device,equipotential bonding,3-stage surge,ground resistance <=1 ohm,KTR-LG,KITOZER
Meta Description:KITOZER KTR-LG data center lightning protection, 3-stage power SPD, signal SPD, equipotential bar, <=1 ohm ground, with weather-bureau test report.
Anchor text:KITOZER by Laian · Data center solutions
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER Brand)
Tel / WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Website: lain.com.cn | gdlain.com