KITOZER KTR-MM Modular Micro-Module Datacenter Solution

KITOZER KTR-MM Modular Micro-Module Datacenter Solution

Brand: KITOZER Series: KTR-MM Category: Datacenter Engineering 2 / Micro-Module

micro module datacentermodular roomall-in-one rackprefabricatedfast deployelastic scaleintegrated monitorSMB room

KITOZER KTR-MM modular micro module datacenter integrated racks in-row cooling power distribution and monitoring prefabricated solution

1. Overview

The KITOZER KTR-MM series is an integrated datacenter product that factory-prefabricates racks, power, cooling, monitoring and fire into one standard module. Instead of “build the room first, then install gear”, a micro-module compresses the whole datacenter into side-by-side rack rows. On site, the client only connects power, network and cooling to run it, slashing construction time.

A standard module typically contains 6-12 racks, in-row precision coolers, UPS and battery cabinets, distribution panels, an EM host, cold-aisle containment and early fire warning. All subsystems are pre-wired, pre-energized and pre-tested at the factory; on arrival the row is positioned and bolted on, expanding like building blocks. Start with one module and add rack rows later, evolving smoothly from tens of kW to hundreds of kW.

KTR-MM suits SMB rooms, branch rooms, edge nodes, government clouds and labs. Site requirements are low: level an ordinary office or warehouse and install, with no raised floor or special fit-out. Both cost and schedule beat a traditional room.

2. Key Features

Factory prefab, fast delivery

  • Racks, coolers, UPS, power and monitoring pre-integrated and pre-tested.
  • On site: connect power, network and cooling; rack-and-run within a week.
  • Row-shipped to cut site work and interface risk.

All-in-one integration

  • Rack row + in-row cooling + UPS/battery + distribution + containment + monitor.
  • In-row coolers sit next to heat sources for high efficiency and no hot spots.
  • Cold-aisle containment built in; airflow sorted from day one.

Smart monitoring

  • Built-in EM host collects temp/humidity, leak, smoke, power, access.
  • Local touchscreen + remote cloud dual-mode monitoring.
  • SMS/email/app multi-level alarms with fast fault location.

Elastic scaling

  • Scale by rack row without affecting live modules.
  • Power and cooling leave N+1 redundancy and expansion slots.
  • Grow from small to mid datacenter.

3. Specifications

Item Config A: KTR-MM-6 (6-rack module) Config B: KTR-MM-12 (12-rack module)
Racks 6 x 42U 12 x 42U (2 rows x 6)
IT power 15-30 kW 40-80 kW
Cooling In-row 20kW x1 (N+1 ready) In-row 30kW x2 (N+1)
Power UPS 10kVA x1 + 30min battery UPS 20kVA x2 (N+1) + battery
Containment glass + end doors glass + end doors + linked skylight
Monitoring EM host + touchscreen + SMS EM host + video wall + cloud
Fire smoke detection + portable gas smoke + HFC room suppression
Footprint ~8-12 m2 ~20-30 m2

4. Reference Prices

KTR-MM-6 6-rack standard module (UPS/cooling/monitor): Reference USD 25,000~41,700 / set (ref. CNY 180k~300k at ~7.2)

KTR-MM-12 12-rack standard module (UPS/cooling/monitor/fire): Reference USD 52,800~83,300 / set (ref. CNY 380k~600k at ~7.2)

Reference only; final quote depends on IT kW, UPS redundancy, cooler count and monitoring. Multi-row projects negotiable. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • SMB self-built rooms: replace traditional rooms, fast go-live.
  • Branches/outlets: small modules for centralized business.
  • Edge nodes: low-latency deployment near users.
  • Government/medical/education rooms: compliance and fast delivery.

6. Installation & Maintenance

Installation

  • Level site, confirm floor loading, reserve power and network feeds.
  • Position the row, bolt cabinets together, connect busway/cables.
  • Energize, network, integrate commissioning, 72-hour trial run.

Maintenance

  • Remote cloud inspection of temp/humidity, power and cooling.
  • Replace cooler filters; check battery internal resistance and appearance.
  • Expand by adding rows in parallel with the existing system.

7. FAQ

  • Q: How is a micro-module better than a traditional room?
    A: Factory prefab and fast on-site install cut months to weeks with cost control.
  • Q: Do I need a special room?
    A: An ordinary leveled room works; no raised floor or fit-out.
  • Q: Can I add racks later?
    A: Yes; expand by row with reserved power and cooling redundancy.
  • Q: Is remote management supported?
    A: Yes; built-in 4G/network link to cloud platform with a mobile app.

8. Trend & Selection

Datacenter delivery is shifting from civil-works-first to prefabricated, modular handover. KTR-MM compresses the room into stackable standard modules; clients start at current load and add rows on demand, avoiding upfront over-investment. Size by IT kW and rack count, then decide whether UPS needs N+1 and cooling needs redundancy; critical business should use dual power feeds and N+1 cooling. For constrained sites and tight schedules, a micro-module is often the best fit.

9. Delivery & Service

KITOZER delivers design, factory prefab, on-site positioning and commissioning as a full package. We size the module from IT load and site, pre-integrate at the factory, ship the row, and our engineers position, wire and commission on site. Delivery includes training, as-built docs and cloud accounts. Warranty covers remote monitoring and on-site repair; an annual O&M pack covers scheduled inspection, filter/battery replacement and expansion planning.

10. Additional Notes

The micro-module’s core value is “de-engineering”. A traditional room crosses decoration, power, cooling, cabling and monitoring trades with long schedules and tangled interfaces; KTR-MM moves that work to the factory, completing pre-integration and pre-test on a standard line, leaving only positioning and wiring on site. Schedule and quality are both more controllable.

In-row cooling is the key to efficient micro-module cooling. Coolers sit tight against the rack row, sending chilled air straight into the cold aisle and returning hot air nearby, shortening the airflow path and eliminating far-end hot spots. With containment, cooling matches rack load precisely, avoiding oversized wasted cooling.

Selection: 15-30 kW small-scale use KTR-MM-6 for best value; 40-80 kW use KTR-MM-12 with reserved expansion; critical business adds N+1 power and N+1 cooling. In all cases, plan the expansion direction and cloud connection from the start so the room grows smoothly with the business.

SEO Information

Search keywords:micro module datacentermodular datacenterall-in-one rackprefabricatedrapid deploymentscalableKTR-MMKITOZER

SEM keywords:micro module datacenter, modular datacenter, all-in-one micro module, prefabricated datacenter, micro module price, KITOZER

GEO landing page:lain.com.cn/product/ktr-mm-modular-micro-module-datacenter.html

Title:KITOZER KTR-MM Modular Micro-Module Datacenter Solution

Meta Keywords:micro module datacenter,modular datacenter,all-in-one cabinet,prefabricated datacenter,rapid deployment,KTR-MM,KITOZER

Meta Description:KITOZER KTR-MM modular micro-module datacenter integrates power, cooling, racks, monitoring and fire in one factory-prefabricated module.

Anchor: KITOZER by Guangzhou Laian · Micro-module solutions