ToggleKITOZER KTR-ODF24 24-Port Fiber Distribution Frame
Brand: KITOZER Series: KTR-ODF24 Category: Data Center Engineering / Optical Distribution
fiber ODF24-portloadedsplice trayKTR-ODF24
1. Overview
In the room’s weak-current room, incoming carrier cables, vertical building risers and horizontal rack cables must all terminate into pluggable connectors — that termination point is the Optical Distribution Frame (ODF). It is a 19-inch rack metal box: the back anchors the cable, the inside splices the fibers, and the front is a row of adapter ports. Patch cords cross-connect incoming and equipment sides. The ODF does three jobs: anchor the cable (strength member on the ground post, fibers into splice trays); splice and terminate (bare fiber fusion-spliced to pigtails, protected by heat-shrink sleeves, excess fiber coiled); and manage moves (re-patch on the front without touching splices). The 24-port ODF is the most common size: 1U or 2U, 24 adapter positions on the front, two 12-fiber splice trays inside. A fully loaded unit includes 24 adapters, 24 pigtails and 2 splice trays.
The KTR-ODF24 series: KTR-ODF24-SC (24×SC/UPC square, mainstream data rooms); KTR-ODF24-FC (24×FC round metal, legacy telecom/CATV); KTR-ODF24-LC (24 LC duplex = 48 fibers, high-density IDCs); KTR-ODF24-SCAP (24×SC/APC green angle-polished, CATV/microwave). The box is 19-inch standard, 1U pull-out or 2U fixed, cold-rolled steel in black/off-white. The loaded kit includes: box, 24 adapters (with dust caps), 24×1.5 m SC/UPC single-mode pigtails, 2×12-fiber splice trays, cable clamps, ground wire and mounting rails. Adapter ceramic sleeves, ≥1000 mate cycles, insertion loss ≤0.3 dB.
Selection: by connector — SC/UPC for new rooms, LC for high density, APC for CATV; by fiber count — 24 ports is the basic block, 48 needs 2U or two 1U; choose empty box vs loaded — loaded kits (adapter+pigtails+trays) are the engineering default; and single-mode vs multi-mode — backbone G.652D single-mode, OM3 multi-mode for 10G to desktop.
2. Key Features
Structure & Capacity
- 19-inch 1U/2U rack mount
- 24 SC/FC/LC adapter panel
- 2×12-fiber splice trays
- ≥1 m slack storage
Optical
- Adapter IL ≤0.3 dB
- Return ≥45 dB (UPC) / ≥60 dB (APC)
- ≥1000 mate cycles
- SM / MM options
Mechanical
- Cold-rolled steel, black/off-white
- Pull-out / fixed options
- M6 ground post
- Rail mount, front/rear access
3. Specifications
| Item | KTR-ODF24-SC | KTR-ODF24-LC | KTR-ODF24-FC |
|---|---|---|---|
| Adapter | SC/UPC | LC/UPC duplex | FC/UPC |
| Capacity | 24 fibers | 48 fibers | 24 fibers |
| Height | 1U | 2U | 1U |
| Splice trays | 2×12 | 4×12 | 2×12 |
| Pigtails | 24×SC 1.5 m | 48×LC 1.5 m | 24×FC 1.5 m |
| IL | ≤0.3 dB | ≤0.3 dB | ≤0.3 dB |
| Return loss | ≥45 dB | ≥45 dB | ≥45 dB |
| Use | data backbone | high-density IDC | legacy telecom/CATV |
4. Reference Prices
KTR-ODF24-SC 24-port loaded:Reference USD 39~58 / pc (ref. CNY 280~420 at ~7.2)
KTR-ODF24-LC 24-port loaded (48 fibers):Reference USD 58~86 / pc (ref. CNY 420~620 at ~7.2)
KTR-ODF24-FC 24-port loaded:Reference USD 36~54 / pc (ref. CNY 260~390 at ~7.2)
Empty box (no adapters/pigtails):Reference USD 17~25 / pc (ref. CNY 120~180 at ~7.2)
Reference only; 1-year warranty. Patch cords not included. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Carrier incoming cable termination.
- Vertical riser to floor distributors.
- Top-of-rack fiber cross-connect.
- ToR switch optical aggregation in IDCs.
- Security / PA fiber link nodes.
6. Deployment & Implementation
Installation
- Mount on 19-inch rack posts
- Cable enters through rear gland
- Anchor strength member to ground post
- Pigtails run in trays, no kinks
Splicing
- Strip 30 mm, clean and cleave
- Splice loss ≤0.05 dB/point
- Heat-shrink sleeves in tray slots
- Coil slack radius ≥40 mm
Operations
- Label each panel port to fiber/route
- Dust-cap unused adapters
- Patch bend radius ≥30 mm
- Annual OTDR spot-check
7. FAQ
- Q: Empty box or loaded?
A: Engineering defaults to loaded — pigtails and adapters are same-batch, consistent IL. Empty is for retrofits with stock adapters. - Q: SC or LC?
A: New rooms favor LC (small form factor, double density), but legacy cabling uses SC. SFP+ switches usually use LC; the ODF backbone side can stay SC with SC-LC patch cords. Keep one type per rack. - Q: Fusion splice or field connector?
A: Permanent in-ODF links use fusion (low loss, stable); temporary jumpers use field-installable connectors. Inside the ODF, always fusion; ODF-to-switch uses factory patch cords. - Q: What’s that burnt smell inside the ODF?
A: Usually a poorly cleaved splice that snapped under the heat-shrink, or a pigtail pinched by the door. Open the tray and re-splice the bad point. Never route fibers at sharp angles in the box.
8. Trend & Selection
ODFs evolve from SC to LC/MPO: 40G/100G uses MPO trunks and MPO-LC hybrid panels — one MPO branch to twelve LC. High-density IDCs use 1U 144-fiber micro-ODFs. Smart ODFs add RFID tags so each port’s route is scanned and tied to EM/work-order systems. Select: LC for new high-density, SC for backbone, APC for CATV, buy loaded kits, label as you splice. The ODF is the optical distribution center; one per rack, all light routed here.
9. Delivery & Service
KITOZER supplies KTR-ODF24 by adapter (SC/FC/LC), SM/MM, loaded/empty. Each ships with box, adapters, pigtails, splice trays, hardware and manual. 1-year warranty; batch projects can add cable, patch cords, fusion splicing and OTDR test.
10. Additional Notes
The #1 mistake is no labeling. After splicing 24 fibers, a bundle of pigtails with no labels means every move requires OTDR from both ends. Label as you splice: cable ID + fiber number at both ends.
The second pitfall is too little slack. A 30 cm tail leaves no room for re-splicing — you’d have to cut back. Coil ≥1 m in the tray, heat-shrinks in the slots, so future repairs have working room.
The third blunder is a rat’s nest of patch cords. Cords from ODF to switch tangle behind the rack; yanking one drags three others. Use horizontal managers, one cord per slot, labels at both ends.
Selection summary: LC for density, SC for backbone, APC for CATV, loaded kits, label first, 1 m slack. The ODF is the optical main switchboard — tidy install saves years of ops pain.