KITOZER KTR-ODF24 24-Port Fiber Optic Distribution Frame (Rack Mount SC)

KITOZER KTR-ODF24 24-Port Fiber Optic Distribution Frame (Rack Mount SC)

Brand: KITOZER Series: KTR-ODF24 Category: Data Center Engineering / Structured Cabling

24-portrack mountSC adaptersplice trayKTR-ODF24

1. Overview

The KITOZER KTR-ODF24 is a 19-inch rack-mount 24-port fiber distribution frame (ODF) for termination, splicing and patching of room backbone fiber cables. The ODF24 is 1U (24-port SC simplex) or 2U (24-port SC duplex / LC), containing 2~4 pull-out splice trays, each splicing 12 fibers. The cable enters from the rear, is anchored at the cable clamp, loose tubes branch into trays, pigtails fusion-splice to fibers, and pigtail SC connectors snap into front-panel adapters.

The front panel carries 24 SC adapters (APC or UPC), arranged in 3 columns × 8 rows, numbered 01~24, with a clear label strip for fiber number and far-end location. Trays are drawer-style: pull out for splicing, push back after. Each tray holds fusion-splice sleeves and excess fiber loops. Top and bottom have cable clamps and a ground post for the cable armor.

The ODF24 housing is 1.2 mm CRS, powder-coated black (RAL9004) to match the rack interior. Adapters can be SC/FC/ST/LC; pigtails SM/MM, APC/UPC. The ODF24 supports both direct splice and cross-connect patching. In structured cabling, the ODF is the first termination node after outside cable enters the room, managing backbone fiber physically; port density, splice capacity and ease of operation directly shape cabling quality.

2. Key Features

24-port rack

  • 19-inch standard.
  • 1U / 2U.
  • 24 SC adapters.
  • Ports 01~24.

Pull-out splice trays

  • 2~4 drawer trays.
  • 12 fibers each.
  • Splice sleeve slots.
  • Excess fiber storage.

Cable grounding

  • Rear cable entry.
  • Armor clamp.
  • Ground post.
  • Loose tube branching.

Multi-adapter option

  • SC/FC/ST/LC adapters.
  • APC / UPC.
  • SM / MM pigtails.
  • Clear label strip.

3. Specifications

Item Parameter
Model KTR-ODF24
Size 19-inch rack 24-port
Rack height 1U (SC simplex) / 2U (duplex)
Adapters 24 SC (FC/ST/LC opt.)
Splice trays 2~4 trays, 12 fibers each
Adapter polish APC / UPC (opt.)
Cable entry 2 holes top/bottom rear
Mounting M6 floating nuts
Housing 1.2 mm CRS powder coat
Color black RAL9004
Grounding ground post to room bar
Packaging carton

4. Reference Prices

KTR-ODF24 24-port SC simplex ODF (adapters + trays): Reference USD 35~69 / unit (ref. CNY 250~500 at ~7.2)

KTR-ODF24 24-port LC duplex ODF (adapters + trays): Reference USD 49~97 / unit (ref. CNY 350~700 at ~7.2)

KTR-ODF24 splice tray (spare): Reference USD 7~14 / layer (ref. CNY 50~100 at ~7.2)

Reference only; exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Room backbone termination.
  • Main distribution area ODF.
  • Floor / rack fiber patching.
  • FTTx room ODF.
  • WDM systems.

6. Installation & Maintenance

Installation

  • Fix ODF to rack 19″ rails.
  • Feed cable through rear entry.
  • Strip armor and anchor.
  • Branch loose tubes to trays.
  • Fuse pigtails to fibers.
  • Snap SC connectors into adapters.

Maintenance

  • Clean adapter end faces.
  • Keep label strip legible.
  • Neatly store excess fiber.
  • Tighten cable clamp.
  • Cap spare ports.
  • Periodic loss test.

7. FAQ

  • Q:ODF vs fiber terminal box?
    A:ODF is rack-mount, high port density (24/48/96), for room backbone; terminal box is wall/desktop, low port count (4/8/12), for FTTH or small-scale termination. Use ODF for room backbone.
  • Q:Fusion splice vs mechanical splice?
    A:In ODF, fusion splice: low loss (≤0.05 dB), reliable, stable long-term; mechanical splice (fast connector) has higher loss (≤0.5 dB) and moisture sensitivity, only for emergency repair. Use fusion in rooms.
  • Q:How many fibers in a 24-port ODF?
    A:24 SC simplex adapters = 24 fibers (one port per fiber). With LC duplex, 24 ports = 48 fibers. Each tray holds 12 fibers; 24-port needs 2 trays.
  • Q:Should cable armor be grounded?
    A:Yes. The metal armor bonds to the ODF ground post and to the room equipotential bar, preventing lightning-induced voltage along the metal into the room. Ground resistance ≤4 Ω.

8. Trend & Selection

Fiber frames are moving toward high density (1U/48/96/144 ports), modular pull-out cassettes and factory pre-termination. MPO high-density ODF is growing in 40G/100G data-center backbones. Select ODF by fiber count and port type (SC/LC/MPO), reserving 30% spare ports.

9. Delivery & Service

KITOZER sizes KTR-ODF24 by fiber count and adapter type, providing port layout and tray arrangement. Delivery includes ODF frame, pre-installed adapters, splice trays, pigtails, cable clamps and certificates. Warranty covers splice loss testing and port management guidance.

10. Additional Notes

A common pitfall is coiling excess fiber too tightly inside the tray. Bend radius under 30 mm raises loss and can break fibers. Coil excess into loops ≥60 mm diameter in the storage area.

Another pitfall is patching dirty adapters. Invisible dust inside the adapter creates micro-scratches that accumulate and raise loss. Use a cleaning pen before every patching.

Selection summary: 24-port rack ODF; pull-out trays; SC/LC option; APC/UPC; armor grounded. The ODF is the core node of room fiber cabling — clear port planning, clean splicing, legible labels keep fiber links efficiently managed.