KITOZER KTR-ODF48SC13 48-Port SC Fiber ODF (19″ Rack Mount)

KITOZER KTR-ODF48SC13 48-Port SC Fiber ODF (19″ Rack Mount)

Brand: KITOZER Series: KTR-ODF48SC13 Category: Fiber Distribution / ODF

48-port SC19″ racksplice traybackbone terminationKTR-ODF

1. Overview

The KITOZER KTR-ODF48SC13 is a 48-port SC optical distribution frame (ODF) in a 19″ rack-mount enclosure, installed in server or network racks to terminate, splice and patch backbone fiber cables. The front holds 48 SC adapter ports (SM/MM options); the rear provides cable entry and splice trays. The backbone cable enters from below, is prepared, fusion-spliced to pigtails, with splices housed in trays; pigtails mate through adapters to external patch cords, fixing, protecting and routing the fiber link.

The KTR-ODF48SC13 is 2U high, cold-rolled steel powder-coated, with four 12-fiber splice trays. The adapter panel flips up for splicing. Cable entry has a rubber grommet and strain clamp to protect the cable. Pigtail bend radius is ≥30 mm to avoid performance loss. 48 SC simplex ports carry 48 fibers (24 duplex links). SC/LC/FC and UPC/APC are available.

In room cabling, the ODF is the junction of backbone and horizontal cabling. Typical uses: campus cable entry termination, fiber patching between core switches and patch panels, backbone expansion and routing. Each ODF manages 48 fibers; large rooms deploy multiple ODFs side by side based on fiber count.

2. Key Features

48-port SC density

  • 48 SC ports.
  • 2U height.
  • SM/MM options.
  • UPC/PC endface.

Built-in splice trays

  • 4 × 12-fiber trays.
  • Flippable panel.
  • Bend radius ≥30 mm.
  • Splice protection.

19″ rack mount

  • Standard 19″.
  • 2U.
  • Cold-rolled steel.
  • Front/rear entry.

Cable protection

  • Rubber grommet.
  • Cable clamp.
  • Pigtail management ring.
  • Label slots.

3. Specifications

Item Parameter
Model KTR-ODF48SC13
Ports 48 SC
Fiber mode SM 9/125 or MM 50/125
Endface UPC (blue) / APC (green)
Height 2U
Mounting 19″ rack
Splice trays 4 × 12-fiber
Bend radius ≥30 mm
Adapter loss ≤0.3 dB
Housing cold-rolled steel
Cable entry bottom / rear
Color black

4. Reference Prices

KTR-ODF48SC13 48-port SC SM ODF (with adapters): Reference USD 49~97 / unit (ref. CNY 350~700 at ~7.2)

KTR-ODF48LC13 48-port LC duplex ODF: Reference USD 63~125 / unit (ref. CNY 450~900 at ~7.2)

KTR-ODF24SC 24-port SC ODF (smaller): Reference USD 28~56 / unit (ref. CNY 200~400 at ~7.2)

Reference only; exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Campus cable entry termination.
  • Core switch fiber patching.
  • Backbone cable splice/routing.
  • Data center fiber distribution.
  • Carrier room ODF frames.

6. Installation & Maintenance

Installation

  • Fix ODF to rack square holes.
  • Backbone cable enters from bottom.
  • Aramid/steel strength member clamped.
  • Fusion-splice pigtails to cable.
  • House splices in trays.
  • Insert SC adapters in panel.
  • Patch cord to switch.

Maintenance

  • Clean adapter endfaces quarterly.
  • Check pigtail bend radius.
  • Reconcile port labels.
  • Stock spare adapters.
  • Test splice loss yearly.
  • Archive patch routing records.

7. FAQ

  • Q:High ODF insertion loss — how to find it?
    A:Clean adapter endfaces and patch cords first, then OTDR each segment. A bad splice needs re-splicing; a bad adapter needs replacement. Single splice ≤0.1 dB, adapter ≤0.3 dB.
  • Q:SC 48 vs LC 48 — choose?
    A:SC ferrule 2.5 mm, 48 SC = 48 fibers; LC ferrule 1.25 mm, 48 LC duplex = 48 fibers (24 pairs). LC is denser for data centers; SC is lower cost for traditional rooms.
  • Q:Why clamp the cable strength member?
    A:The aramid/steel strength member carries tension; if not clamped, the cable pulls out and pigtails snap. Fix it to the ODF entry clamp so the housing bears the tension, not the pigtails.
  • Q:Why leave pigtail slack in trays?
    A:Splices may need rework later; reserve 1~2 m pigtail coiled in the tray. Without slack, re-splicing requires re-opening the cable.

8. Trend & Selection

ODFs are trending high-density (MPO/MTP pre-terminated), smart (port identification) and factory pre-terminated. In 40G/100G data centers, MPO-LC pre-connected cables are growing. Select by fiber count, port type (SC/LC/MPO), SM/MM and rack U space.

9. Delivery & Service

KITOZER sizes KTR-ODF48SC13 by backbone fiber count, providing splice layout and port coding. Delivery includes ODF body, SC adapters, splice trays, cable clamps, certificate and manual. Warranty covers splice loss testing guidance and port label printing.

10. Additional Notes

A common pitfall is too-tight pigtail bending. Radius under 30 mm adds macrobend loss and can break the fiber over time. Route pigtails naturally in trays at ≥30 mm; never hard-fold.

Another pitfall is leaving adapters uncapped. Dirt in unused ports raises loss and scratches patch cord endfaces. Cap unused ports and clean endfaces before mating.

Additionally, in high-density rooms, use a cable management arm behind the ODF so patch cords do not bind when pulled. Label both ends of every patch cord with circuit ID; tracing unlabeled cords in a 48-port panel is time-consuming. When splicing, keep the fiber buffer intact up to the splice protector — stripping too far weakens the joint.

Selection summary: 48-port SC; 2U rack; 4 splice trays; SM/MM; backbone termination. The ODF is the main entrance of room fiber — good splices, managed pigtails, clear labels keep the backbone routable.