KITOZER
KITOZER

KITOZER KTR-OS-2403 Refrigeration Oil Separator (Centrifugal, 24mm)

KITOZER KTR-OS-2403 Refrigeration Oil Separator (Centrifugal, 24mm)

Brand: KITOZER Series: KTR-OS-2403 Category: Refrigeration Parts / Oil Separator

CentrifugalCold storage oil return24mm portHigh efficiencyKTR-OS-2403

1. Overview

The KITOZER KTR-OS-2403 is a centrifugal refrigeration oil separator installed between the compressor discharge line and the condenser. It separates lubricating oil carried by high-pressure refrigerant gas and returns it to the compressor crankcase. During compressor operation, oil in the crankcase is atomized by the rotating connecting rods and swept out with the hot discharge gas. Without an oil separator, this oil travels with the refrigerant into the condenser, evaporator and expansion valve, starving the compressor of lubrication (scoring) while depositing an insulating oil film on heat-exchanger walls and fouling the expansion valve. KTR-OS-2403 uses centrifugal swirl plus a filter element to capture over 98% of entrained oil droplets and returns them to the compressor.

Specs: inlet/outlet 24 mm solder ports; working pressure 4.5 MPa; compatible refrigerants R22/R404A/R410A/R134a; separation efficiency >=98%; shell diameter 89 mm; total height about 220 mm; oil-return port 1/4 inch; sight glass for oil-return observation; steel shell with coated finish. Compared with simple mesh separators, the centrifugal type handles larger gas volumes with lower pressure drop and resists fouling, suiting medium-to-large cold rooms and chillers. Mount upright on the discharge line; the return line connects below the crankcase oil level.

Typical uses: cold storage compressor racks (modular / low-temperature rooms); screw or piston water chillers; air-source heat pumps; industrial process refrigeration; commercial HVAC outdoor units; containerized refrigeration. One KTR-OS-2403 per 5 to 15 HP compressor; parallel compressors each need their own separator (do not share).

2. Key Features

Centrifugal + filter two-stage

  • Tangential inlet spins gas; oil droplets fling to the wall.
  • Secondary filter traps sub-micron droplets.
  • Total efficiency >=98%.
  • Pressure drop <0.02 MPa.

Sight-glass oil return

  • Sight glass on the return line.
  • Observe continuous oil flow during operation.
  • Verify return-line blockage.
  • Detect oil starvation early.

Wide refrigerant compatibility

  • R22/R404A/R410A/R134a.
  • 4.5 MPa working pressure.
  • Medium/low-temperature duty.
  • High-pressure steel shell.

Solder ports, reliable

  • Inlet/outlet 24 mm copper/steel solder.
  • Return line 1/4 inch flare.
  • Upright mount.
  • Coated anti-corrosion shell.

3. Specifications

Item Parameter
Model KTR-OS-2403
Type Centrifugal oil separator
Inlet port 24 mm (solder)
Outlet port 24 mm (solder)
Return port 1/4 inch (flare)
Working pressure 4.5 MPa
Refrigerants R22/R404A/R410A/R134a
Efficiency >=98%
Shell diameter 89 mm
Total height about 220 mm
Sight glass Yes
Shell Coated steel
Mounting Upright

4. Reference Prices

KTR-OS-2403 centrifugal (24 mm): Ref. USD 25~39 / pc (CNY 180~280 at 7.2)

KTR-OS-1802 small port (18 mm): Ref. USD 17~25 / pc (CNY 120~180 at 7.2)

KTR-OS-2804 large port (28 mm): Ref. USD 36~53 / pc (CNY 260~380 at 7.2)

Return-line solenoid valve: Ref. USD 8~14 / pc (CNY 60~100 at 7.2)

Replacement sight glass: Ref. USD 3~5 / pc (CNY 20~35 at 7.2)

Companion refrigeration oil: Ref. USD 11~21 / L (CNY 80~150 at 7.2)

Reference only; 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Modular cold room compressor racks.
  • Low-temperature rooms (-18 C / -25 C).
  • Screw water chillers.
  • Air-source heat pumps (hot water / heating).
  • Industrial process refrigeration.
  • Commercial HVAC outdoor units.

6. Installation & Maintenance

Installation

  • Mount upright on the compressor discharge line.
  • Inlet from compressor; outlet to condenser.
  • Follow the arrow (gas flows top to bottom).
  • Return line connects below crankcase oil level.
  • Install sight glass and return solenoid on the return line.
  • Solder with nitrogen purge to prevent oxide scale.
  • Pressure test: 4.5 MPa N2, 24 h drop <0.02 MPa.
  • Evacuate, charge refrigerant and oil.
  • Commission: verify continuous oil flow at sight glass.

Maintenance

  • Monthly inspect sight glass; flow should be continuous.
  • If flow stops, check solenoid and blockage.
  • Quarterly check shell for frost (not normal; indicates poor return or overcharge).
  • Annually change refrigeration oil (with compressor service).
  • Rebuild internal filter every 3 to 5 years.
  • Do not install shut-off valves at inlet/outlet (breaks oil return).
  • Repair damaged insulation promptly to prevent condensation.

7. FAQ

  • Q:What if the separator is installed backwards?
    A:Efficiency collapses and oil floods the condenser; the compressor quickly starves. The arrow on the shell must match gas direction (top inlet, bottom outlet). If reversed, desolder and reinstall—do not run it reversed.
  • Q:No oil visible in the sight glass—normal?
    A:At low load, intermittent return is normal. But if after 30 min of running there is no flow and crankcase level keeps dropping, the return path is blocked: check the solenoid, ice/oil blockage, and return orifice. Poor return scores the compressor.
  • Q:Can one compressor use two separators?
    A:Usually unnecessary. One KTR-OS-2403 covers 5 to 15 HP. Parallel compressors each need their own separator; do not share, or oil migrates between them.
  • Q:Does the separator need insulation?
    A:For low-temperature duty (discharge line below ambient dew point), insulate with 15 to 20 mm elastomeric foam to prevent surface condensation. For medium/high-temperature discharge (60 to 90 C) it is not required, but if surface temperature is below dew point, insulate anyway.

8. Trend & Selection

Oil separators evolve from simple mesh to centrifugal plus high-efficiency filter, lifting efficiency from 90% to over 98%. Integration of oil-level control and return solenoids is growing. Environmental refrigerants (R32, R1234yf) demand higher pressure ratings and POE-oil compatibility. Units are shrinking for residential heat pumps. Select by compressor HP and port size—undersized separators cause poor oil return; oversized units add unnecessary pressure drop.

9. Delivery & Service

KITOZER sizes KTR-OS separators by compressor HP and port diameter, providing solder dimensions and return-line routing guidance. Delivery includes the separator, sight glass, manual and certificate. Warranty covers soldering guidance and return-system commissioning.

10. Additional Notes

A common pitfall is soldering without nitrogen purge. Oxide scale forms inside hot tubing and is flushed into the expansion valve, causing blockage. Purge with low-pressure N2 (0.02 MPa) during soldering, then vent.

Another pitfall is an undersized or over-long return line. Minimum 1/4 inch ID, length under 3 m, sloping downward to the crankcase—no upward bends that trap oil.

Selection summary: centrifugal; efficiency >=98%; 24 mm port; sight glass; upright mount. The oil separator is the lung of the refrigeration unit; the keys are correct direction, unobstructed return, and timely oil changes.

Extra tip: after initial start-up of a new system, check the crankcase oil level after 24 h. The separator internals hold some oil initially; top up to 1/2 to 2/3 of the sight glass.

Contact Us

KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Scroll to Top