Table of Contents
ToggleKITOZER KTR-OS36 Vertical Cyclone Oil Separator for Precision Cooling
Brand: KITOZER Series: KTR-OS36 Category: Data Center Engineering / Refrigeration
VerticalCyclone98% efficiencyKTR-OS36
1. Overview
The KITOZER KTR-OS36 is a vertical precision oil separator that uses high-efficiency cyclone separation. Discharge gas enters the shell tangentially and spins along the inner wall; oil droplets are flung to the wall by centrifugal force, slide down into the bottom oil sump, while clean refrigerant vapor exits through the top center outlet. Unlike baffle or filter-type separators, the cyclone design needs no replacement element, offers low pressure drop, and suits around-the-clock precision cooling runs. The vessel mounts vertically in the discharge line between compressor and condenser, taking minimal floor space.
The KTR-OS36 core advantage lies in its optimized cyclone chamber geometry. A guide cone and swirl vanes at the top establish a stable spiral flow; the bottom expanded section slows the gas so fine droplets coalesce and settle. Under nominal conditions, discharge oil carryover drops from 3-5% at inlet to below 0.1% at outlet, achieving over 98% separation. The bottom sump accumulates recovered oil and returns it to the crankcase through a capillary tube by pressure differential, keeping the lubrication loop closed.
Typical install: on a 50 kW datacenter precision AC, place one KTR-OS36 in the vertical discharge run—inlet from compressor (Φ18 or Φ22 per pipe size), outlet upward to condenser—bolt it on a frame, run a 6 mm capillary from the bottom port to the crankcase, and use the side sight glass to monitor oil return. It fits R22, R410A, R134a and some R407C systems across 3-15 HP. Size the shell by displacement, ports by pipe diameter, and seals by refrigerant.
2. Key Features
Cyclone separation
- Tangential inlet swirl.
- Centrifugal throw.
- Guide cone vane.
- 98%+ efficiency.
Filter-free
- No consumable element.
- No replacement cost.
- Low pressure drop.
- Continuous operation.
Vertical compact
- Straight vertical run.
- Small footprint.
- Flange or thread.
- Bottom return port.
Wide refrigerant
- R22/410A/134a.
- R407C partial.
- 3-15 HP.
- Seals per refrigerant.
3. Specifications
| Item | KTR-OS36 (Cyclone) | KTR-OS20 (Baffle) | KTR-OS10 (Economy) |
|---|---|---|---|
| Principle | Centrifugal cyclone | Baffle+gravity | Gravity settle |
| Mounting | Vertical | Vertical | Vertical |
| Capacity | 3-15 HP | 2-10 HP | 1-5 HP |
| Ports | Φ18/Φ22 | Φ16/Φ20 | Φ12/Φ16 |
| Efficiency | 98%+ | ~90% | ~80% |
| Sump | Yes (sight glass) | Yes (small) | No |
| Element | None (maintenance-free) | None | None |
| Refrigerant | R22/410A/134a/407C | R22/410A/134a | R22/134a |
4. Reference Prices
KTR-OS36 vertical cyclone separator (3-15 HP): Reference USD 56 to 167 / unit (ref. CNY 400 to 1200 at ~7.2)
KTR-OS20 standard baffle (2-10 HP): Reference USD 35 to 83 / unit (ref. CNY 250 to 600 at ~7.2)
KTR-OS10 economy (1-5 HP): Reference USD 17 to 49 / unit (ref. CNY 120 to 350 at ~7.2)
Return capillary + check valve kit: Reference USD 4 to 11 / set (ref. CNY 30 to 80 at ~7.2)
Reference only; varies by port size, refrigerant, connection type and qty. Capillary, check valve and bracket billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Datacenter precision AC oil return.
- Constant-temp/humidity lab AC.
- Chiller discharge lines.
- Rooftop AC units.
- Continuous-operation compressor protection.
6. Installation & Maintenance
Installation
- Mount vertically, follow marks.
- Anchor frame against vibration.
- Run bottom capillary to crankcase.
- Add check valve on return line.
- Nitrogen-purge while brazing.
- Evacuate, pressure-test, charge.
Maintenance
- Check sight glass for oil return.
- Low oil level means blocked return.
- Keep capillary clear.
- Inspect drain plug for leaks.
- Log discharge temp and oil trend.
- No element to replace.
7. FAQ
- Q: Cyclone or filter type?
A: Cyclone (KTR-OS36) has no consumables, low pressure drop and suits continuous runs. Filter type offers finer separation but needs scheduled element changes. Choose cyclone for datacenter precision cooling. - Q: What does 98% mean?
A: Over 98% of oil in discharge gas is returned to the crankcase; outlet gas carryover is very low, reducing oil on condenser and expansion valve to improve heat exchange. - Q: What if return port clogs?
A: The sump fills and gets re-entrained while the crankcase starves. If the sight glass shows full oil and the crankcase level is low, clear the capillary immediately. - Q: Can I lay it horizontal?
A: The KTR-OS36 is designed vertical; horizontal mounting destroys the swirl field and drops efficiency. Use a horizontal model if space does not allow vertical runs.
8. Trend & Selection
Precision cooling moves toward efficiency and long life; compressor lubrication is decisive for reliability. Cyclone separators are replacing baffle and filter types because they have no consumables, low pressure drop and high efficiency. Select by HP for shell size, by pipe diameter for ports, by refrigerant for seals; put a branch separator on each parallel compressor; add a check valve on the return capillary; inspect the sight glass regularly. The KTR-OS36 protects compressor lubrication with proven cyclone technology.
9. Delivery & Service
KITOZER supplies oil-return kits: based on compressor model, refrigerant and pipe size we recommend the KTR-OS36 plus capillary, check valve and brackets, bundled with precision-AC refrigeration accessories. Delivery includes body, fittings, bracket and manual; bulk projects get brazing and install guidance. Shell leaks or failed port seals under warranty are replaced free.
10. Additional Notes
The common mistake is reversing inlet and outlet. The shell marks flow direction; swapping them destroys the swirl field and collapses separation efficiency. Align the arrow with gas flow.
Another pitfall is using too thin or too long a capillary. Thin capillaries clog easily; long ones add return resistance. Use 6 mm ID, keep length under 3 m, and minimize bends.
Selection summary: vertical mount, cyclone separation, 98%+ efficiency, 3-15 HP, filter-free, bottom return with check valve. The KTR-OS36 separates oil efficiently and returns it smoothly for long compressor life.
SEO Information
Search keywords:oil separatorvertical oil separatorcyclone separatorprecision ac oil returncompressor lubricationKTR-OS36KITOZER
SEM keywords:[vertical oil separator price,cyclone separator supplier,precision ac oil return,refrigeration separator,KTR-OS36,KITOZER]
GEO landing page:lain.com.cn/product/ktr-os36-vertical-cyclone-oil-separator.html
Title:KITOZER KTR-OS36 Vertical Cyclone Oil Separator for Precision Cooling
Meta Keywords:oil separator,vertical oil separator,cyclone separator,precision ac oil return,compressor lubrication,KTR-OS36,KITOZER
Meta Description:KITOZER KTR-OS36 vertical cyclone oil separator with 98%+ efficiency, filter-free, for 3-15 HP precision cooling units.
Anchor: KITOZER · Data Center Engineering
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com