KITOZER
KITOZER

KITOZER KTR-OSC-20 Centrifugal Compressed Air Oil Separator (20 m3/min)

KITOZER KTR-OSC-20 Centrifugal Compressed Air Oil Separator (20 m3/min)

Brand: KITOZER Series: KTR-OSC-20 Category: Oil Separator / Centrifugal

centrifugal20 m3/min1.6 MPa98% oil removalKTR-OSC-20

1. Overview

The KITOZER KTR-OSC-20 is a centrifugal compressed-air oil separator installed between the outlet of an oil-injected screw compressor and the air receiver tank. Its job is to bulk-remove liquid oil droplets entrained in the compressed air (lubricating oil mist at 1 to 50 microns). Without oil removal, the downstream dryers, desiccants, pneumatic valves and cylinders suffer desiccant poisoning, seal swelling and product contamination. KTR-OSC-20 uses cyclonic centrifugal force: oil-laden air enters tangentially and spins rapidly inside the vessel; because oil droplets are denser than air, they are flung against the vessel wall, run down to the sump, while clean air exits through the center outlet.

The centrifugal oil separator is a bulk (pre-) separator: it targets liquid droplets larger than about 5 microns at about 98% efficiency. It cannot remove oil vapor or sub-micron aerosols; those require downstream coalescing filters (0.01 micron) and activated-carbon filters. The typical train is: compressor outlet -> KTR-OSC-20 bulk separation -> receiver tank -> refrigerated dryer -> 1-micron pre-filter -> 0.01-micron coalescing filter -> activated carbon (oil vapor) -> point of use. As the first bulk-removal stage, KTR-OSC-20 extends the life of the downstream precision elements by 3 to 5 times, cutting running cost.

KTR-OSC-20 handles 20 m3/min (matching a 110 to 132 kW oil-injected screw compressor), at 1.6 MPa working pressure and 66 C, with DN50 flanged ports. The vessel is carbon-steel powder-coated with an internal 304 stainless swirl vane, and a float-type automatic drain at the bottom. Besides oil removal, the cyclone also drops condensed water (water droplets are flung out the same way), giving two benefits in one unit.

2. Key Features

Cyclonic principle

  • Tangential inlet + swirl vanes create high-speed rotation.
  • Droplets flung to wall by centrifugal force.
  • 98% efficiency on droplets >5 microns.
  • Low pressure drop (<=0.02 MPa) saves compressed-air energy.

High flow

  • Rated 20 m3/min.
  • Suits 110 to 132 kW screw compressors.
  • DN50 flanged ports.
  • 1.6 MPa working pressure.

Auto drain

  • Float-type automatic drain at sump.
  • Sight glass shows oil level.
  • Drain line to waste oil bucket.
  • No frequent manual draining.

Durable build

  • Carbon-steel powder-coated shell.
  • 304 stainless internal vanes.
  • Quick-open cover for service.
  • Vertical, small footprint.

3. Specifications

Item Parameter
Model KTR-OSC-20
Type Centrifugal cyclone oil separator
Rated flow 20 m3/min (at ambient)
Working pressure 0.3 to 1.6 MPa
Design pressure 1.6 MPa
Working temp up to 66 C
Efficiency >=98% on liquid droplets >5 microns
Pressure drop <=0.02 MPa
Ports DN50 flange
Shell material Carbon steel powder coat; 304 SS internal vanes
Drain Float auto drain + sight glass
Dimensions approx. dia280 x H950 mm
Mounting Vertical floor or wall bracket
Matched compressor 110 to 132 kW oil-injected screw

4. Reference Prices

KTR-OSC-20 (20 m3/min, DN50): Ref. USD 250~361 / unit (CNY 1800~2600 at 7.2)

KTR-OSC-10 small (10 m3/min, DN40): Ref. USD 153~222 / unit (CNY 1100~1600 at 7.2)

KTR-OSC-40 large (40 m3/min, DN80): Ref. USD 486~667 / unit (CNY 3500~4800 at 7.2)

Float auto drain (spare): Ref. USD 11~21 / pc (CNY 80~150 at 7.2)

Sight glass (spare): Ref. USD 4~8 / pc (CNY 30~60 at 7.2)

DN50 flange gasket: Ref. USD 1.5~3 / pc (CNY 10~20 at 7.2)

Reference only; 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • After oil-injected screw compressor outlet.
  • Pneumatic tools in injection workshops.
  • Spray painting lines (oil/water-free air).
  • SMT pneumatic tools in electronics plants.
  • Pneumatic valves in pharma plants (oil-free).
  • Packaging lines in food plants.

6. Installation & Maintenance

Installation

  • Mount vertically between compressor outlet and receiver, close to the compressor.
  • Connect the tangential inlet to compressor outlet; the top outlet to the receiver.
  • Follow the arrow on the vessel; do not reverse.
  • Run a clear tube from the bottom drain to a waste oil bucket.
  • Use DN50 flange gaskets; tighten bolts diagonally.
  • Anchor the vessel with M10 expansion bolts.
  • Install a bypass line for service without shutdown.
  • Commission: check the sight glass for oil flow and verify pressure drop <=0.02 MPa.

Maintenance

  • Weekly: check sight glass level; empty waste oil bucket.
  • Quarterly: open the quick cover and inspect swirl vanes for scaling.
  • Clean vanes with diesel and blow out with compressed air.
  • Annually: service the auto drain; clean the float if it sticks.
  • Touch up paint where chipped (rust protection).
  • Calibrate gauges every six months.
  • Do not kink the drain tube (a kink stops draining and oil overflows to outlet).

7. FAQ

  • Q:Centrifugal vs coalescing oil separator?
    A:A centrifugal unit (KTR-OSC-20) uses centrifugal force to fling out large droplets (>5 microns) at 98%, with low pressure drop and no replacement elements; it is a bulk pre-filter at the compressor outlet. A coalescing unit uses glass-fiber elements to catch sub-micron droplets (<1 micron) at 99.9%, but needs periodic element changes. The typical train is centrifugal first (protects the element) then coalescing (gets outlet oil to <1 ppm).
  • Q:Outlet air still has oil?
    A:The centrifugal unit only removes bulk liquid droplets, not oil vapor or aerosols. If the use point requires oil-free air (pharma, food, spraying), add a downstream 0.01-micron coalescing filter and an activated-carbon filter. The carbon element lasts about 2000 hours. Test with a white paper: spray at the outlet; oil spots mean the train is not sufficient.
  • Q:Drain keeps blowing air?
    A:The float drain is stuck open, letting compressed air escape through the drain line. Remove the drain, clean the float and seat (debris often jams it). If it still leaks after cleaning, replace the drain unit. A leaking drain wastes huge compressor energy and inflates the power bill; fix it immediately.
  • Q:Is oversizing a waste?
    A:Oversizing costs more and takes space, and can actually hurt efficiency. Size the separator slightly above the compressor rated flow (10% margin). A 110 kW compressor at 20 m3/min pairs with KTR-OSC-20. If you use KTR-OSC-40 (40 m3/min) on a 20 m3/min compressor, the air moves too slowly in the vessel, centrifugal force drops, and efficiency falls. Size to the nameplate flow, not bigger.

8. Trend & Selection

Compressed-air after-treatment moves from water-only removal to combined water/oil/dust treatment. Cyclone vessels go from plain carbon steel to stainless (food and pharma grade). Drains move from float to electronic timed drains with blockage alarms. Oil-free compressors (magnetic bearing, water-lubricated) gradually replace oil-injected units, reducing demand for oil separators, but the installed base of oil-injected machines is still large. Energy optimization targets lower pressure drop (from 0.02 MPa toward 0.01 MPa) and variable-speed compressors with heat recovery.

9. Delivery & Service

KITOZER sizes KTR-OSC-20 by compressor power and rated flow, supplying flange drawings and piping recommendations. Delivery includes vessel, float drain, sight glass, flange gaskets, certificate and manual. Warranty covers vane cleaning guidance and drain replacement support.

10. Additional Notes

A common pitfall is reversing the ports. The cyclone inlet is tangential on the side, and the clean outlet is on the top center. Installers sometimes connect top-in and bottom-out out of convenience; the air does not spin, droplets are not flung out, and the vessel becomes an empty pipe. Read the arrow on the vessel before connecting.

Another pitfall is no bypass. During service the compressor must stop, halting production. Add a bypass line with two ball valves so maintenance can happen without shutdown.

Selection summary: centrifugal; 20 m3/min; DN50; 1.6 MPa; 98% bulk removal. The cyclone is the first bulk-removal stage; the keys are correct orientation, quarterly vane cleaning, and downstream precision filters for true oil-free air.

Additional tip: KTR-OSC-20 must be installed after the after-cooler, not on the high-temperature side. Inlet temperature above 66 C ages the gaskets quickly and shortens service life. The compressor’s built-in oil separator runs hot; place KTR-OSC-20 downstream of the cooler.

Contact Us

KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com