ToggleKITOZER KTR-PSM9 Three-Phase Class-C 40KA Surge Protective Device
Brand: KITOZER Series: KTR-PSM9 Category: Power Distribution / Surge Protection
Three-phase SPDClass C 40KADIN railRemote contactFailure indicatorSurge protection
1. Overview
Lightning and grid switching surges are hidden killers of data center gear. During a strike, surges invade through power and signal lines; thousands of volts of spikes punch through power modules and mainboards, batch-destroying UPS and servers. A surge protective device (SPD) is a parallel “discharge path” across the power line — high impedance at normal times, but it conducts instantly during a surge, clamping peak voltage to what equipment can take and dumping current to ground. Data center protection is staged: main switchgear uses Class B (100KA+), floor/hall cabinets use Class C (40KA), and device front ends use Class D (10KA), each stage coordinating to clamp step by step.
KITOZER KTR-PSM9 is a three-phase Class-C 40KA power SPD. Plug-in modular structure, 35 mm DIN rail, installed on the incoming side of the hall cabinet (row PDU). One module per pole (three phases + N + PE), max discharge current 40KA (8/20 μs), nominal 20KA, voltage protection level ≤1.8 kV. Each module has a failure indicator window (green OK / red failed) and a remote-signaling auxiliary contact (dry contact to the DCIM platform for auto-alarm on SPD failure). A backup protection breaker (32~63A) must be series-wired upstream to prevent SPD short-circuit fire. Operating voltage 385 VAC (three-phase).
Selection points: protection class (B/C/D coordination; hall distribution generally Class C), max discharge current (40 KA is typical Class C; lightning-prone areas choose 60KA), pole count (three-phase five-wire uses 4P+N), remote-signaling need (must have contacts if tied to DCIM), backup protection (upstream breaker rating), and mounting (DIN rail vs screw). Note SPDs have a service life — every surge discharge ages the module; when the window turns red it must be replaced, otherwise it is as if none is installed.
2. Key Features
Three-phase Class C 40KA
- Max discharge 40KA.
- Nominal 20KA.
- Clamp ≤1.8 kV.
- 385 VAC operation.
Modular plug-in
- 35 mm DIN rail.
- Modules replaceable individually.
- Hot-swap (with caution).
- Easy maintenance.
Remote failure signal
- Green/red window.
- Dry contact remote.
- Ties to DCIM.
- Auto-alarm on failure.
Backup protection
- Upstream series breaker.
- Prevents SPD short.
- Fire safety.
- 32~63 A rating.
3. Specifications
| Item | KTR-PSM9 |
|---|---|
| Model | KTR-PSM9 |
| Protection class | Class C (secondary) |
| Max discharge (8/20μs) | 40KA/pole |
| Nominal discharge | 20KA/pole |
| Voltage protection level | ≤1.8 kV |
| Max continuous voltage | 385 VAC |
| Poles | 4P+N (3P5W) |
| Mounting | 35 mm DIN rail |
| Failure indicator | Green/red window |
| Remote contact | Dry (5A/250VAC) |
| Backup protection | Upstream breaker 32~63 A |
| Response time | ≤25 ns |
4. Reference Prices
KTR-PSM9 three-phase Class C 40KA SPD (4P+N, DIN rail, remote signal): Reference USD 49~90 / set (ref. CNY 350~650 at ~7.2)
KTR-PSM9B 60KA reinforced version (with backup breaker): Reference USD 76~132 / set (ref. CNY 550~950 at ~7.2)
Reference only; tiered by poles and current. Grounding busbar work not included. Volume discount above 5 sets. Class D final SPD available in same series. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Row cabinet / power cabinet secondary protection.
- UPS incoming surge protection.
- AC and power equipment distribution front end.
- Outdoor feeder box protection.
- Lightning-prone area power systems.
6. Installation & Maintenance
Installation
- With power off, clip SPD onto 35 mm rail.
- Upstream to phases (L1/L2/L3) and N; downstream to PE bus.
- Series-wire upstream backup breaker (32~63 A).
- Wire remote contact to DCIM module.
- Before energizing, verify tight wiring and green window.
Maintenance
- Monthly visual window check (replace when red).
- Inspect modules after thunderstorms.
- Measure ground resistance yearly (≤4 Ω).
- Tighten terminals periodically (thermal cycling loosens).
- Test remote-signal function annually.
7. FAQ
- Q: Can I keep using a red-window SPD?
A: No. The module has degraded/shortened; replace immediately — otherwise fire risk. - Q: How to coordinate Class C and D?
A: Main cabinet Class B → row cabinet Class C (KTR-PSM9) → PDU front Class D; keep 10 m between stages or add decoupling inductor. - Q: What does the remote contact connect to?
A: A DCIM dry-contact input module; SPD failure triggers a platform alarm. - Q: What if no backup breaker?
A: An SPD short without upstream protection can ignite — always series a breaker or fuse.
8. Trend & Selection
Protection evolves from “single SPD” to “staged coordination + condition monitoring.” Trends: SPDs with remote signaling and discharge counters (predict lifespan), smart SPDs (Modbus read module status), plug-in modules (hot-swap without outage), and linkage with online ground-resistance monitoring. Selection: hall distribution uses Class C 40KA; lightning-prone areas choose 60KA; three-phase five-wire 4P+N; remote signaling to DCIM is mandatory; upstream backup breaker cannot be skipped; replace on red window; measure ground yearly. SPDs are consumables — install is not the end; an aged un-replaced unit is a paid-for hazard.
9. Delivery & Service
KITOZER provides SPD selection: by distribution stage, lightning risk, and DCIM monitoring needs, we configure SPD class, poles, and remote-signal scheme. Bundled with power cabinets, grounding busbars, and DCIM modules. Delivery includes SPD body, modules, remote-contact wiring, and manual. Warranty covers wiring guidance and remote-signal commissioning.
10. Additional Notes
The most common fault: “SPD installed but remote signal not wired.” Operators don’t know the SPD has aged until a surge destroys equipment and they finally see the red window. The remote contact must go to DCIM for auto-alarm — otherwise the SPD is a blind insurance policy, discovered only after the damage.
Another pitfall: “overlong SPD ground lead.” Surge discharge needs the shortest path; a lead over 0.5 m adds inductance that raises clamp voltage and degrades protection. Mount SPD near the PE bus with a short, thick copper wire.
Selection summary: Class C 40KA 3P5W; remote signal to DCIM; upstream backup breaker; short ground to PE; replace on red; yearly ground test. SPDs are high-leverage protection — a few-hundred-yuan device saves hundreds-of-thousands in equipment, but only if it’s healthy, wired right, and can alarm.
SEO Information
Search keywords:three-phase SPDclass C 40KA surge protectorDIN rail SPDremote contact SPDcabinet surge protectionKTR-PSM9KITOZER
SEM keywords:three-phase SPD price,class C 40KA surge protector,DIN rail SPD,cabinet surge protection,KTR-PSM9,KITOZER
GEO landing page:lain.com.cn/product/ktr-psm9-three-phase-class-c-40ka-surge-protective-device.html
Title:KITOZER KTR-PSM9 Three-Phase Class-C 40KA Surge Protective Device
Meta Keywords:three-phase SPD,class C 40KA,DIN rail,remote contact,surge protective device,KTR-PSM9,KITOZER
Meta Description:KITOZER KTR-PSM9 three-phase class-C 40KA SPD, 35mm DIN rail, remote contact and failure indicator, for secondary surge protection in data center power cabinets.
Anchor: KITOZER by Guangzhou Laian · Data center power surge protection
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com