Table of Contents
ToggleKITOZER KTR-SC4APC SC Quad APC OM3 Fiber Optic Adapter
Brand: KITOZER Series: KTR-SC4APC Category: Data Center Engineering / Fiber Connectors
SC quadAPC polishOM3 multimodeceramic sleeveKTR-SC4APC
1. Overview
The KITOZER KTR-SC4APC is an SC quad APC OM3 multimode fiber adapter, also called a fiber coupler or flange. It mounts on a patch panel, terminal box or enclosure panel, and accepts two SC jumpers from each side to make a dematable joint between two fiber links. “Quad” means one adapter housing integrates four SC channels (two duplex SC), completing four fibers through a single panel cut-out and doubling density while reducing cut-out count. “APC” means an 8-degree angled physical contact polish, which greatly reduces back reflection versus flat UPC and is preferred in PON, video and high-speed optical links. “OM3” denotes 10G multimode fiber (50/125 μm, aqua) supporting 10Gbps and above.
The core is a precision zirconia ceramic sleeve whose inner bore matches the 125 μm ferrule for accurate axial alignment and minimal insertion loss. The outer housing is engineering plastic (PC/ABS) or metal with a latch that snaps into the SC cut-out on the panel. APC connectors are color-coded green to distinguish them from blue UPC; never mix them. SC uses a push-pull latch, convenient on high-density patch panels.
In room low-voltage systems, the fiber adapter is the most numerous passive interconnect, mounted in ODF frames, rack-mount terminal boxes and wall boxes to join backbone cable to equipment jumpers. The KTR-SC4APC quad adapter packs four SC channels into limited panel space and is a common choice for high-density OM3 10G cabling, used with SC APC OM3 jumpers and OM3 cable to form a low-loss, low-reflection multimode link.
2. Key Features
Quad high density
- Four SC channels in one body.
- Fewer panel cut-outs.
- Higher density.
- Double the duplex count.
APC angled polish
- 8-degree angled polish.
- Low back reflection.
- Green housing marker.
- No UPC mixing.
OM3 10G multimode
- 50/125 μm aqua.
- Supports 10Gbps.
- 10G multimode links.
- Paired with OM3 jumpers.
Precision ceramic sleeve
- Zirconia ceramic.
- 125 μm bore.
- Low insertion loss.
- High mate cycles.
3. Specifications
| Item | Parameter |
|---|---|
| Model | KTR-SC4APC |
| Connector type | SC quad (4 channels) |
| Polish | APC (8-degree angle) |
| Fiber type | OM3 50/125 μm multimode |
| Sleeve | zirconia ceramic |
| Insertion loss | ≤0.3 dB |
| Return loss | ≥60 dB (APC) |
| Mate cycles | ≥500 |
| Operating temp | -20~70℃ |
| Housing color | green (APC marker) |
4. Reference Prices
KTR-SC4APC SC quad APC OM3 adapter (each): Reference USD 2.5~5 / pc (ref. CNY 18~35 at ~7.2)
KTR-SC4APC box of 50: Reference USD 105~195 / box (ref. CNY 750~1400 at ~7.2)
Reference only; better per-unit price by box. Patch panels and jumpers excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- High-density ODF patching.
- Rack-mount fiber terminal boxes.
- 10G multimode cross-connect.
- Data center rack fiber patching.
- Low-voltage room splicing trays.
6. Installation & Maintenance
Installation
- Snip into SC panel cut-out.
- Confirm latch seated.
- Insert SC APC jumpers both sides.
- Keep end faces clean.
- Listen for latch click.
- Test link insertion loss.
Maintenance
- Clean end faces with a pen.
- Cap unused ports.
- Avoid repeated wear.
- Separate APC from UPC.
- Sample-test optical power.
- Replace contaminated adapters.
7. FAQ
- Q: Can APC and UPC mate?
A: Not recommended. APC is angled 8 degrees, UPC flat; mating them scratches the angle and raises loss. Pair APC with APC and UPC with UPC. Green = APC, blue = UPC — never mix. - Q: Quad vs duplex?
A: Duplex has two fibers (one Tx/Rx); a quad housing has four channels (two Tx/Rx), doubling fibers in the same cut-out for high density. Use duplex for small counts, quad for dense patching. - Q: Are OM3 and OM4 adapters interchangeable?
A: Physically they fit, but use OM4-rated adapters for OM4 links for consistency. OM3 jumpers into an OM4 adapter work mechanically but bandwidth is limited to OM3. - Q: What does 0.3 dB insertion loss mean?
A: ≤0.3 dB per adapter is a good grade. Loss accumulates across every adapter and splice in a link, so budget all of them in the optical power margin and leave headroom.
8. Trend & Selection
Data center fiber patching moves toward high density and high bandwidth; OM3/OM4 10G multimode and low-reflection APC grow, and quad adapters become the high-density panel choice. Select APC (green) or UPC (blue) by polish, OM3/OM4 by fiber, quad for density, and match jumpers and cleaning tools.
9. Delivery & Service
KITOZER selects KTR-SC4APC quantity by panel cut-outs and fiber count, providing panel drilling drawings and end-face cleaning guidance. Delivery includes adapters, dust caps and certificates. Warranty covers insertion-loss testing and cleaning guidance.
10. Additional Notes
A common pitfall is mating dirty end faces. Micron-scale dust causes sudden loss spikes and can scratch the ceramic ferrule. Clean every end face before mating with a cleaning pen or alcohol wipe, and keep dust caps on unused ports.
Another pitfall is mixing APC and UPC on the same panel. Green APC and blue UPC differ structurally; cross-mating scratches the angle. Label zones on the panel and match jumper polish to adapter polish, checking housing color before install.
Selection summary: SC quad four channels; APC 8-degree low reflection; OM3 10G multimode; ceramic sleeve low loss; green housing marker; for high-density panels. Small as it is, the adapter is a key node of link loss and reliability — clean faces, matched polish, sensible density keep 10G links running at full bandwidth.
Contact Us
KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com