KITOZER
KITOZER

KITOZER KTR-SC4APC SC Quad APC OM3 Fiber Optic Adapter

KITOZER KTR-SC4APC SC Quad APC OM3 Fiber Optic Adapter

Brand: KITOZER Series: KTR-SC4APC Category: Data Center Engineering / Fiber Connectors

SC quadAPC polishOM3 multimodeceramic sleeveKTR-SC4APC

1. Overview

The KITOZER KTR-SC4APC is an SC quad APC OM3 multimode fiber adapter, also called a fiber coupler or flange. It mounts on a patch panel, terminal box or enclosure panel, and accepts two SC jumpers from each side to make a dematable joint between two fiber links. “Quad” means one adapter housing integrates four SC channels (two duplex SC), completing four fibers through a single panel cut-out and doubling density while reducing cut-out count. “APC” means an 8-degree angled physical contact polish, which greatly reduces back reflection versus flat UPC and is preferred in PON, video and high-speed optical links. “OM3” denotes 10G multimode fiber (50/125 μm, aqua) supporting 10Gbps and above.

The core is a precision zirconia ceramic sleeve whose inner bore matches the 125 μm ferrule for accurate axial alignment and minimal insertion loss. The outer housing is engineering plastic (PC/ABS) or metal with a latch that snaps into the SC cut-out on the panel. APC connectors are color-coded green to distinguish them from blue UPC; never mix them. SC uses a push-pull latch, convenient on high-density patch panels.

In room low-voltage systems, the fiber adapter is the most numerous passive interconnect, mounted in ODF frames, rack-mount terminal boxes and wall boxes to join backbone cable to equipment jumpers. The KTR-SC4APC quad adapter packs four SC channels into limited panel space and is a common choice for high-density OM3 10G cabling, used with SC APC OM3 jumpers and OM3 cable to form a low-loss, low-reflection multimode link.

2. Key Features

Quad high density

  • Four SC channels in one body.
  • Fewer panel cut-outs.
  • Higher density.
  • Double the duplex count.

APC angled polish

  • 8-degree angled polish.
  • Low back reflection.
  • Green housing marker.
  • No UPC mixing.

OM3 10G multimode

  • 50/125 μm aqua.
  • Supports 10Gbps.
  • 10G multimode links.
  • Paired with OM3 jumpers.

Precision ceramic sleeve

  • Zirconia ceramic.
  • 125 μm bore.
  • Low insertion loss.
  • High mate cycles.

3. Specifications

Item Parameter
Model KTR-SC4APC
Connector type SC quad (4 channels)
Polish APC (8-degree angle)
Fiber type OM3 50/125 μm multimode
Sleeve zirconia ceramic
Insertion loss ≤0.3 dB
Return loss ≥60 dB (APC)
Mate cycles ≥500
Operating temp -20~70℃
Housing color green (APC marker)

4. Reference Prices

KTR-SC4APC SC quad APC OM3 adapter (each): Reference USD 2.5~5 / pc (ref. CNY 18~35 at ~7.2)

KTR-SC4APC box of 50: Reference USD 105~195 / box (ref. CNY 750~1400 at ~7.2)

Reference only; better per-unit price by box. Patch panels and jumpers excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • High-density ODF patching.
  • Rack-mount fiber terminal boxes.
  • 10G multimode cross-connect.
  • Data center rack fiber patching.
  • Low-voltage room splicing trays.

6. Installation & Maintenance

Installation

  • Snip into SC panel cut-out.
  • Confirm latch seated.
  • Insert SC APC jumpers both sides.
  • Keep end faces clean.
  • Listen for latch click.
  • Test link insertion loss.

Maintenance

  • Clean end faces with a pen.
  • Cap unused ports.
  • Avoid repeated wear.
  • Separate APC from UPC.
  • Sample-test optical power.
  • Replace contaminated adapters.

7. FAQ

  • Q: Can APC and UPC mate?
    A: Not recommended. APC is angled 8 degrees, UPC flat; mating them scratches the angle and raises loss. Pair APC with APC and UPC with UPC. Green = APC, blue = UPC — never mix.
  • Q: Quad vs duplex?
    A: Duplex has two fibers (one Tx/Rx); a quad housing has four channels (two Tx/Rx), doubling fibers in the same cut-out for high density. Use duplex for small counts, quad for dense patching.
  • Q: Are OM3 and OM4 adapters interchangeable?
    A: Physically they fit, but use OM4-rated adapters for OM4 links for consistency. OM3 jumpers into an OM4 adapter work mechanically but bandwidth is limited to OM3.
  • Q: What does 0.3 dB insertion loss mean?
    A: ≤0.3 dB per adapter is a good grade. Loss accumulates across every adapter and splice in a link, so budget all of them in the optical power margin and leave headroom.

8. Trend & Selection

Data center fiber patching moves toward high density and high bandwidth; OM3/OM4 10G multimode and low-reflection APC grow, and quad adapters become the high-density panel choice. Select APC (green) or UPC (blue) by polish, OM3/OM4 by fiber, quad for density, and match jumpers and cleaning tools.

9. Delivery & Service

KITOZER selects KTR-SC4APC quantity by panel cut-outs and fiber count, providing panel drilling drawings and end-face cleaning guidance. Delivery includes adapters, dust caps and certificates. Warranty covers insertion-loss testing and cleaning guidance.

10. Additional Notes

A common pitfall is mating dirty end faces. Micron-scale dust causes sudden loss spikes and can scratch the ceramic ferrule. Clean every end face before mating with a cleaning pen or alcohol wipe, and keep dust caps on unused ports.

Another pitfall is mixing APC and UPC on the same panel. Green APC and blue UPC differ structurally; cross-mating scratches the angle. Label zones on the panel and match jumper polish to adapter polish, checking housing color before install.

Selection summary: SC quad four channels; APC 8-degree low reflection; OM3 10G multimode; ceramic sleeve low loss; green housing marker; for high-density panels. Small as it is, the adapter is a key node of link loss and reliability — clean faces, matched polish, sensible density keep 10G links running at full bandwidth.

Contact Us

KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Scroll to Top