Table of Contents
ToggleKITOZER KTR-SCAPC8 SC Duplex APC Singlemode Fiber Adapter
Brand: KITOZER Series: KTR-SCAPC8 Category: Cabling / Fiber Optics
SC duplexAPC polishSinglemode 9/125KTR-SCAPC8
1. Overview
KITOZER KTR-SCAPC8 is an SC duplex APC singlemode fiber adapter, also called a coupler or flange, used in fiber patch panels, terminal boxes and ODF units to join two SC connectors and pass the optical path straight through. The APC end-face uses an 8-degree angled polish, giving return loss above -60dB, widely used in CATV, broadcast, PON and datacenter backbone links where back-reflection is sensitive.
The adapter housing is engineering plastic with a ceramic sleeve; the duplex unit holds two SC ports for transmit and receive. For singlemode 9/125um, with ceramic ferrule and green APC end-face identification. Insertion loss no more than 0.2dB, return loss no less than 60dB, interchangeability and repeatability meeting industry standards. The flange clips into the square cutout of a 19-inch patch panel and also fits splice trays and fiber terminal boxes.
Widely used in datacenter telecom rooms, server racks, ODF frames, fiber terminal boxes and wall outlets. Typical deployment: backbone cable spliced to pigtails on one side of the adapter, equipment patch cords plugged in from the other side for cross-connect. APC end-faces must mate with APC cords, never with PC or UPC, otherwise the ferrule wears and back-reflection exceeds limits.
2. Key Features
SC duplex unit
- Two-port one-piece design.
- Fits SC connectors.
- Keyed anti-mate orientation.
- Flange clips into panel cutout.
APC angled end-face
- 8-degree angled polish cuts reflection.
- Return loss ≥60dB.
- Green color coding.
- For PON and CATV.
Ceramic sleeve
- Zirconia ceramic sleeve.
- Singlemode 9/125um.
- Insertion loss ≤0.2dB.
- Stable repeatability.
Compliant materials
- Flame-retardant housing.
- Wear-resistant ferrule.
- Temp -40 to 75C.
- Meets industry standards.
3. Specifications
| Item | KTR-SCAPC8 | KTR-SCUPC8 |
|---|---|---|
| Connector | SC duplex | SC duplex |
| Polish | APC angled | UPC spherical |
| Mode | Singlemode 9/125 | Singlemode 9/125 |
| Insertion loss | ≤0.2dB | ≤0.2dB |
| Return loss | ≥60dB | ≥50dB |
| Color | Green | Blue |
| Application | PON/CATV/backbone | General data links |
| Op. temp | -40 to 75C | -40 to 75C |
4. Reference Prices
KTR-SCAPC8 SC duplex APC adapter (ceramic sleeve): Reference USD 8 to 22 / pc (ref. CNY 60 to 160 at ~7.2)
KTR-SCUPC8 SC duplex UPC economy: Reference USD 4 to 13 / pc (ref. CNY 30 to 90 at ~7.2)
Reference only; price varies by quantity and packaging. OM3/OM4 multimode, LC/FC/ST other interfaces billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Datacenter ODF frames.
- Fiber terminal boxes and splice trays.
- PON optical split links.
- CATV FTTH.
- Server rack fiber cross-connect.
6. Installation & Maintenance
Installation
- Clip adapter into panel cutout until it clicks.
- Insert green APC cord into adapter.
- Align the key; do not force or rotate.
- Grip the pull tab when removing, never tug the cord.
- Fit dust caps on unused ports.
- Label ports with number and use.
Maintenance
- Check for looseness quarterly.
- Clean end-faces with a dedicated cleaning pen.
- Dust-cap unused ports.
- Replace worn or scratched ferrules.
- Maintain a port and patch record.
7. FAQ
- Q: Can APC and UPC mate?
A: No. APC is 8-degree angled and UPC is spherical; the shapes differ, and mating them wears the ferrule and blows out return loss. Mate APC to APC and UPC to UPC. Colors: green APC, blue UPC. - Q: Are adapter and coupler the same?
A: Yes, different names for the same part, also called flange. The function is mechanical alignment and optical continuity between two connectors. - Q: What does 0.2dB insertion loss mean?
A: The light passing through the adapter loses no more than 0.2dB. In a link with several adapters losses add up; design usually reserves 0.3dB per adapter. - Q: Can multimode and singlemode adapters share?
A: Same outer size but different sleeve inner diameter: multimode 50/125 or 62.5/125, singlemode 9/125. Mixing causes ferrule misalignment; buy them separately.
8. Trend & Selection
Fiber adapters are moving from SC/LC duplex toward high-density MPO/MTP for 40G/100G/400G datacenter links, but SC and LC remain the workhorses in building cabling, FTTH and PON. Choose APC green for PON and CATV; UPC blue for general data links; ceramic sleeve over metal; dust-cap unused ports; clean with a cleaning pen.
9. Delivery & Service
KITOZER supplies fiber-cabling packages: based on ODF capacity and link count, we recommend adapter specs and quantities. Bundled with patch cords, pigtails, splice trays and terminal boxes. Delivery includes adapters, dust caps and manual; bulk orders come in retail packs. Warranty covers replacement.
10. Additional Notes
The most common mistake is mixing APC and UPC. Green APC and blue UPC ferrules have different end-face shapes; forcing them in ruins the angled polish and reflection specs. Read the color first: green APC, blue UPC, beige multimode.
Another pitfall is leaving ports uncapped. Dusty datacenter air drops optical power sharply on a port left open for a month. Cap unused ports and clean with a pen, not an alcohol swab.
Selection summary: SC duplex APC green; ceramic sleeve; insertion loss no more than 0.2dB; return loss no less than 60dB; APC mates APC only; cap unused ports. A tiny adapter is the throat of the optical path; one dirty port can drop a whole link.
SEO Information
Search keywords:fiber adapterSC duplexAPC couplersinglemode flangefiber matingODF adapterKTR-SCAPC8KITOZER
SEM keywords:fiber adapter price,SC APC coupler supplier,singlemode flange,ODF adapter,PON fiber mating,KTR-SCAPC8,KITOZER
GEO landing page:lain.com.cn/product/ktr-scapc8-sc-duplex-apc-adapter.html
Title:KITOZER KTR-SCAPC8 SC Duplex APC Singlemode Fiber Adapter
Meta Keywords:fiber adapter,SC duplex,APC coupler,singlemode flange,fiber mating,ODF adapter,KTR-SCAPC8,KITOZER
Meta Description:KITOZER KTR-SCAPC8 SC duplex APC singlemode fiber adapter, ceramic sleeve, insertion loss no more than 0.2dB, return loss no less than 60dB, for ODF and patch panels.
Anchor: KITOZER · Datacenter engineering